The DOI matches its Crossref record; 83 of the 83 references it cites were found in a registry or an index.
Pre-clinical whole-body fluorescence imaging: Review of instruments, methods and applications
Open accessAbstract
Fluorescence sampling of cellular function is widely used in all aspects of biology, allowing the visualization of cellular and sub-cellular biological processes with spatial resolutions in the range from nanometers up to centimeters. Imaging of fluorescence in vivo has become the most commonly used radiological tool in all pre-clinical work. In the last decade, full-body pre-clinical imaging systems have emerged with a wide range of utilities and niche application areas. The range of fluorescent probes that can be excited in the visible to near-infrared part of the electromagnetic spectrum continues to expand, with the most value for in vivo use being beyond the 630 nm wavelength, because the absorption of light sharply decreases. Whole-body in vivo fluorescence imaging has not yet reached a state of maturity that allows its routine use in the scope of large-scale pre-clinical studies. This is in part due to an incomplete understanding of what the actual fundamental capabilities and limitations of this imaging modality are. However, progress is continuously being made in research laboratories pushing the limits of the approach to consistently improve its performance in terms of spatial resolution, sensitivity and quantification. This paper reviews this imaging technology with a particular emphasis on its potential uses and limitations, the required instrumentation, and the possible imaging geometries and applications. A detailed account of the main commercially available systems is provided as well as some perspective relating to the future of the technology development. Although the vast majority of applications of in vivo small animal imaging are based on epi-illumination planar imaging, the future success of the method relies heavily on the design of novel imaging systems based on state-of-the-art optical technology used in conjunction with high spatial resolution structural modalities such as MRI, CT or ultra-sound.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vivo cancer targeting and imaging with semiconductor quantum dots
Gao, X., Cui, Y., Levenson, R. M., Chung, L. W. K., & Nie, S. (2004) · Nature Biotechnology · doi:10.1038/nbt994 · Cited by 4,772
Fourier transform profilometry for the automatic measurement of 3-D object shapes
Takeda, M., & Mutoh, K. (1983) · Applied Optics · doi:10.1364/ao.22.003977 · Cited by 1,855
Weissleder, R., & Mahmood, U. (2001) · Radiology · doi:10.1148/radiology.219.2.r01ma19316 · Cited by 1,315
QUANTITATIVE OPTICAL SPECTROSCOPY FOR TISSUE DIAGNOSIS
Richards-Kortum, R., & Sevick-Muraca, E. (1996) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.47.1.555 · Cited by 1,172
Peptide-Labeled Near-Infrared Quantum Dots for Imaging Tumor Vasculature in Living Subjects
Cai, W., Shin, D.-W., Chen, K., Gheysens, O., Cao, Q., Wang, S. X., Gambhir, S. S., & Chen, X. (2006) · Nano Letters · doi:10.1021/nl052405t · Cited by 948
In Vivo Fluorescence Spectroscopy and Imaging for Oncological Applications
Wagnieres, G. A., Star, W. M., & Wilson, B. C. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb02521.x · Cited by 942
Fluorescence molecular tomography resolves protease activity in vivo
Ntziachristos, V., Tung, C.-H., Bremer, C., & Weissleder, R. (2002) · Nature Medicine · doi:10.1038/nm729 · Cited by 827
Selective molecular imaging of viable cancer cells with pH-activatable fluorescence probes
Urano, Y., Asanuma, D., Hama, Y., Koyama, Y., Barrett, T., Kamiya, M., Nagano, T., Watanabe, T., Hasegawa, A., Choyke, P. L., et al. (2009) · Nature Medicine · doi:10.1038/nm.1854 · Cited by 801
Aikawa, E., Nahrendorf, M., Figueiredo, J.-L., Swirski, F. K., Shtatland, T., Kohler, R. H., Jaffer, F. A., Aikawa, M., & Weissleder, R. (2007) · Circulation · doi:10.1161/circulationaha.107.732867 · Cited by 698
Mammalian Expression of Infrared Fluorescent Proteins Engineered from a Bacterial Phytochrome
Shu, X., Royant, A., Lin, M. Z., Aguilera, T. A., Lev-Ram, V., Steinbach, P. A., & Tsien, R. Y. (2009) · Science · doi:10.1126/science.1168683 · Cited by 675
Cited by
The acidic tumor microenvironment: a target for smart cancer nano-theranostics
Feng, L., Dong, Z., Tao, D., Zhang, Y., & Liu, Z. (2018) · National Science Review · doi:10.1093/nsr/nwx062 · Cited by 426
Translation of Near-Infrared Fluorescence Imaging Technologies: Emerging Clinical Applications
Sevick-Muraca, E. M. (2012) · Annual Review of Medicine · doi:10.1146/annurev-med-070910-083323 · Cited by 339
Deep learning-enabled multi-organ segmentation in whole-body mouse scans
Schoppe, O., Pan, C., Coronel, J., Mai, H., Rong, Z., Todorov, M. I., Müskes, A., Navarro, F., Li, H., Ertürk, A., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-19449-7 · Cited by 104
In Vivo Fluorescence Imaging of IgG1 Aggregates After Subcutaneous and Intravenous Injection in Mice
Filipe, V., Que, I., Carpenter, J. F., Löwik, C., & Jiskoot, W. (2014) · Pharmaceutical Research · doi:10.1007/s11095-013-1154-9 · Cited by 39
Metadata
- Authors
- Leblond, F., Davis, S. C., Valdés, P. A., & Pogue, B. W.
- Venue
- Journal of Photochemistry and Photobiology B: Biology
- Publisher
- Elsevier BV
- Published
- 2010-01
- Volume
- 98
- Issue
- 1
- Pages
- 77-94
- ISSN
- 1011-1344 (ISSN-L)
- OpenAlex
- W2029606255
- Cited by
- 593
- References
- 83
- FWCI
- 25.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pre-clinical whole-body fluorescence imaging: Review of instruments, methods and applications. https://app.cochat.ai/papers/10.1016/j.jphotobiol.2009.11.007
- The paper
- Leblond, F., Davis, S. C., Valdés, P. A., & Pogue, B. W. (2010). Pre-clinical whole-body fluorescence imaging: Review of instruments, methods and applications. Journal of Photochemistry and Photobiology B: Biology. https://doi.org/10.1016/j.jphotobiol.2009.11.007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.