The DOI matches its Crossref record; 51 of the 51 references it cites were found in a registry or an index.
ProLuCID: An improved SEQUEST-like algorithm with enhanced sensitivity and specificity
Open accessAbstract
ProLuCID, a new algorithm for peptide identification using tandem mass spectrometry and protein sequence databases has been developed. This algorithm uses a three tier scoring scheme. First, a binomial probability is used as a preliminary scoring scheme to select candidate peptides. The binomial probability scores generated by ProLuCID minimize molecular weight bias and are independent of database size. A modified cross-correlation score is calculated for each candidate peptide identified by the binomial probability. This cross-correlation scoring function models the isotopic distributions of fragment ions of candidate peptides which ultimately results in higher sensitivity and specificity than that obtained with the SEQUEST XCorr. Finally, ProLuCID uses the distribution of XCorr values for all of the selected candidate peptides to compute a Z score for the peptide hit with the highest XCorr. The ProLuCID Z score combines the discriminative power of XCorr and DeltaCN, the standard parameters for assessing the quality of the peptide identification using SEQUEST, and displays significant improvement in specificity over ProLuCID XCorr alone. ProLuCID is also able to take advantage of high resolution MS/MS spectra leading to further improvements in specificity when compared to low resolution tandem MS data. A comparison of filtered data searched with SEQUEST and ProLuCID using the same false discovery rate as estimated by a target-decoy database strategy, shows that ProLuCID was able to identify as many as 25% more proteins than SEQUEST. ProLuCID is implemented in Java and can be easily installed on a single computer or a computer cluster. This article is part of a Special Issue entitled: Computational Proteomics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Under serum-free survival conditions, we have previously observed that the cells do not proliferate, and thus we are measuring loss of viability in these cells under serum-free conditions with pharmacological treatment 49.”
From Manumycin polyketides act as molecular glues between UBR7 and P53 (2020) · cites this paper as [49]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring the Accuracy of Diagnostic Systems
Swets, J. A. (1988) · Science · doi:10.1126/science.3287615 · Cited by 10,058
Eng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484
Self-citationKeller, A., Nesvizhskii, A., Kolker, E., & Aebersold, R. (2002) · Analytical Chemistry · doi:10.1021/ac025747h · Cited by 4,970
Large-scale analysis of the yeast proteome by multidimensional protein identification technology
Washburn, M. P., Wolters, D. A., & Yates, J. R. (2001) · Nature Biotechnology · doi:10.1038/85686 · Cited by 4,768
Self-citationProcedures for Detecting Outlying Observations in Samples
Grubbs, F. E. (1969) · Technometrics · doi:10.1080/00401706.1969.10490657 · Cited by 4,105
TANDEM: matching proteins with tandem mass spectra
Craig, R., & Beavis, R. C. (2004) · Bioinformatics · doi:10.1093/bioinformatics/bth092 · Cited by 2,546
Direct analysis of protein complexes using mass spectrometry
Link, A. J., Eng, J. K., Schieltz, D. M., Carmack, E., Mize, G. J., Morris, D. R., Garvik, B. M., & Yates, J. R. (1999) · Nature Biotechnology · doi:10.1038/10890 · Cited by 2,218
Self-citationOlsen, J. V., de Godoy, L. M. F., Li, G., Maček, B., Mortensen, P., Pesch, R., Makarov, A., Lange, O., Horning, S. R., & Mann, M. (2005) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t500030-mcp200 · Cited by 1,539
Protein Analysis by Shotgun/Bottom-up Proteomics
Zhang, Y., Fonslow, B. R., Shan, B., Baek, M.-C., & Yates, J. R. (2013) · Chemical Reviews · doi:10.1021/cr3003533 · Cited by 1,491
Self-citationError-Tolerant Identification of Peptides in Sequence Databases by Peptide Sequence Tags
Mann, M., & Wilm, M. S. (1994) · Analytical Chemistry · doi:10.1021/ac00096a002 · Cited by 1,473
Flagged first, then by citations
Cited by
Sorted by citations
Li, X., Xiong, X., Zhang, M., Wang, K., Chen, Y., Zhou, J. L., Mao, Y., Lv, J., Yi, D., Chen, X., et al. (2017) · Molecular Cell · doi:10.1016/j.molcel.2017.10.019 · Cited by 482
Harnessing the anti-cancer natural product nimbolide for targeted protein degradation
Spradlin, J. N., Hu, X., Ward, C. C., Brittain, S. M., Jones, M. D., Ou, L., To, M., Proudfoot, A., Ornelas, E., Woldegiorgis, M., et al. (2019) · Nature Chemical Biology · doi:10.1038/s41589-019-0304-8 · Cited by 432
“…°C and the nanospray voltage was set to 2.75 kV. Data was extracted in the form of MS1 and MS2 files using Raw Extractor 1.9.9.2 (Scripps Research Institute) and searched against the Uniprot human database using ProLuCID search methodology in IP2 v.3 (Integrated Proteomics Applications, Inc) 36 .”
InfluentialHe, M., Chiang, H.-H., Luo, H., Zheng, Z., Qiao, Q., Wang, L., Tan, M., Ohkubo, R., Mu, W.-C., Zhao, S., et al. (2020) · Cell Metabolism · doi:10.1016/j.cmet.2020.01.009 · Cited by 425
“San Diego, CA) using ProLuCID/Sequest, DTASelect2 and Census (Cociorva et al., 2007; Park et al., 2008; Tabb et al., 2002; Xu et al., 2015).”
MethodDeubiquitinase-targeting chimeras for targeted protein stabilization
Henning, N. J., Boike, L., Spradlin, J. N., Ward, C. C., Liu, G., Zhang, E., Belcher, B. P., Brittain, S. M., Hesse, M. J., Dovala, D., et al. (2022) · Nature Chemical Biology · doi:10.1038/s41589-022-00971-2 · Cited by 344
Dynamic RNA acetylation revealed by quantitative cross-evolutionary mapping
Sas‐Chen, A., Thomas, J. M., Matzov, D., Taoka, M., Nance, K. D., Nir, R., Bryson, K. M., Shachar, R., Liman, G. L. S., Burkhart, B. W., et al. (2020) · Nature · doi:10.1038/s41586-020-2418-2 · Cited by 336
Metadata
- Authors
- Xu, T., Park, S. K., Venable, J. D., Wohlschlegel, J. A., Diedrich, J. K., Cociorva, D., Lu, B., Liao, L., Hewel, J., Han, X., Wong, C. C. L., Fonslow, B., Delahunty, C., Gao, Y., Shah, H., & Yates, J. R.
- Affiliations
- Scripps Research Institute (US)
- Corresponding author
- Yates, J.R.
- ORCID
- Venue
- Journal of Proteomics
- Publisher
- Elsevier BV
- Published
- 2015-11
- Volume
- 129
- Pages
- 16-24
- ISSN
- 1874-3919 (ISSN-L)
- PMC
- PMC4630125
- OpenAlex
- W2182963873
- Cited by
- 511
- References
- 51
- Citations by year
- 2026: 23 · 2025: 41 · 2024: 65 · 2023: 45 · 2022: 51 · 2021: 56 · 2020: 56 · 2019: 60 · 2018: 43 · 2017: 46 · 2016: 22 · 2015: 3
- FWCI
- 16.92
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Locations
- Journal of Proteomics (publishedVersion, cc-by)
- PubMed (publishedVersion)
- Europe PMC (PubMed Central) (acceptedVersion)
- PubMed Central (acceptedVersion)
- eScholarship (California Digital Library) (submittedVersion, cc-by)
- Funders
- NIH (5U01 DE016267-04, 5R01 HL079442-04, R01 MH067880, P41 GM103533)
- NHLBI (HHSN268201000035C)
- Topics
- Physical Sciences › Chemistry › Spectroscopy › Advanced Proteomics Techniques and Applications
- Physical Sciences › Chemistry › Spectroscopy › Mass Spectrometry Techniques and Applications
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Genomics and Phylogenetic Studies
- Keywords
- peptide identification, tandem mass spectrometry, SEQUEST, Z-score
- MeSH terms
- Algorithms, Amino Acid Sequence, Molecular Sequence Data, Pattern Recognition, Automated, Peptide Mapping, Proteins, Sensitivity and Specificity, Software, Reproducibility of Results, Sequence Analysis, Protein, Databases, Protein, Tandem Mass Spectrometry, Data Mining
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review