Lamellar orientation in human cornea in relation to mechanical properties
Abstract
We have applied wide-angle X-ray scattering to the human cornea in order to quantify the relative number of stromal collagen fibrils directed along the two preferred corneal lamellar directions: superior-inferior and nasal-temporal. The data suggest that, on average, the two directions are populated in equal proportion at the corneal centre. Here, approximately one-third of the fibrils throughout the stromal depth tend to lie within a 45 degrees sector of the superior-inferior meridian, and similarly for the nasal-temporal direction. However, in some eyes we have measured significant differences between the two preferential fibril populations, with some corneas exhibiting as much as 25% more collagen in one direction than the other. Based on these findings, a mechanical model of the normal cornea may be envisaged, whereby the fibril tension in the underlying "background" of isotropically arranged collagen helps to balance the intraocular pressure; while the extra preferentially aligned fibrils take up the additional tensile stress along the superior-inferior and nasal-temporal meridians exerted by the rectus muscles and the orbicularis. It is possible that, through a direct impact on the elastic modulus of the tissue, an imbalance of superior-inferior and nasal-temporal fibrils in some eyes might affect corneal shape.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The preferred orientations at the centre of the cornea may help withstand the pull of the extraocular muscles.
“The directions at the centre of the cornea may help withstand the pull of the extraocular muscles”
From Structural control of corneal transparency, refractive power and dynamics (2025) · cites this paper as [17]
Many of these preferred lamellae continue into the sclera and are believed to help the cornea withstand the pull of the extraocular muscles.
“Many of these appear to continue into the sclera and are believed to help the cornea to withstand the pull of the extraocular muscles [17–19] (Fig. 5 inset).”
From Structural control of corneal transparency, refractive power and dynamics (2025) · cites this paper as [17]
Cited by
Sorted by citations
Keeping an Eye on Decellularized Corneas: A Review of Methods, Characterization and Applications
Wilson, S., Sidney, L., Dunphy, S., Rose, J., & Hopkinson, A. (2013) · Journal of Functional Biomaterials · doi:10.3390/jfb4030114 · Cited by 100 · see citing works
Structural control of corneal transparency, refractive power and dynamics
Meek, K. M., Knupp, C., Lewis, P. N., Morgan, S. R., & Hayes, S. (2025) · Eye · doi:10.1038/s41433-024-02969-7 · Cited by 45 · see citing works
Self-citation
- Authors
- Boote, C., Dennis, S., Huang, Y., Quantock, A. J., & Meek, K. M.
- Affiliations
- Cardiff University (GB)
- Beijing Great Wall Hospital (CN)
- Corresponding author
- Boote, Craig
- Venue
- Journal of Structural Biology
- Publisher
- Elsevier BV
- Published
- 2005-01
- Volume
- 149
- Issue
- 1
- Pages
- 1-6
- ISSN
- 1047-8477 (ISSN-L)
- OpenAlex
- W2026419440
- Cited by
- 178
- References
- 0
- Citations by year
- 2026: 4 · 2025: 8 · 2024: 6 · 2023: 9 · 2022: 2 · 2021: 9 · 2020: 9 · 2019: 10 · 2018: 11 · 2017: 6 · 2016: 6 · 2015: 8 · 2014: 10 · 2013: 16 · 2012: 6
- FWCI
- 2.92
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Structural Biology (publishedVersion)
- PubMed (publishedVersion)
- Science and Technology Facilities Council (submittedVersion)
- Funders
- Medical Research Council
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal surgery and disorders
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Corneal Surgery and Treatments
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Keywords
- corneal collagen fibrils, lamellar orientation, corneal stroma, corneal mechanical properties, intraocular pressure, corneal shape, elastic modulus, wide-angle X-ray scattering
- MeSH terms
- Collagen, Cornea, Corneal Stroma, Extracellular Matrix, Humans, Intraocular Pressure, X-Ray Diffraction, Stromal Cells, Mechanics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review