The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Determining the mechanical properties of human corneal basement membranes with atomic force microscopy
Open accessAbstract
Biophysical cues such as substrate modulus have been shown to influence a variety of cell behaviors. We have determined the elastic modulus of the anterior basement membrane and Descemet’s membrane of the human cornea with atomic force microscopy (AFM). A spherical probe was used with a radius approximating that of a typical cell focal adhesion. Values obtained for the elastic modulus of the anterior basement membrane range from 2 kPa to 15 kPa, with a mean of 7.5 ± 4.2 kPa. The elastic modulus of Descemet’s membrane was found to be slightly higher than those observed for the anterior basement membrane, with a mean of 50 ± 17.8 kPa and a range of 20 kPa — 80 kPa. The topography of Descemet’s membrane has been shown to be similar to that of the anterior basement, but with smaller pore sizes resulting in a more tightly packed structure. This structural difference may account for the observed modulus differences. The determination of these values will allow for the design of a better model of the cellular environment as well as aid in the design and fabrication of artificial corneas.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tissue Cells Feel and Respond to the Stiffness of Their Substrate
Discher, D. E., Janmey, P., & Wang, Y.-L. (2005) · Science · doi:10.1126/science.1116995 · Cited by 6,382
Myotubes differentiate optimally on substrates with tissue-like stiffness
Engler, A. J., Griffin, M. A., Sen, S., Bönnemann, C. G., Sweeney, H. L., & Discher, D. E. (2004) · The Journal of Cell Biology · doi:10.1083/jcb.200405004 · Cited by 1,743
Increased stiffness of the rat liver precedes matrix deposition: implications for fibrosis
Georges, P. C., Hui, J.-J., Gombos, Z., McCormick, M. E., Wang, A. Y., Uemura, M., Mick, R., Janmey, P. A., Furth, E. E., & Wells, R. G. (2007) · American Journal of Physiology-Gastrointestinal and Liver Physiology · doi:10.1152/ajpgi.00032.2007 · Cited by 577
Cited by
The impact of the extracellular matrix on inflammation
Sorokin, L. (2010) · Nature Reviews Immunology · doi:10.1038/nri2852 · Cited by 912
Indentation Versus Tensile Measurements of Young's Modulus for Soft Biological Tissues
McKee, C. T., Last, J. A., Russell, P., & Murphy, C. J. (2011) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2010.0520 · Cited by 708
Self-citationThe elastic modulus of Matrigel™ as determined by atomic force microscopy
Soofi, S. S., Last, J. A., Liliensiek, S. J., Nealey, P. F., & Murphy, C. J. (2009) · Journal of Structural Biology · doi:10.1016/j.jsb.2009.05.005 · Cited by 309
Self-citationIn situ force mapping of mammary gland transformation
Lopez, J. I., Kang, I., You, W.-K., McDonald, D. M., & Weaver, V. M. (2011) · Integrative Biology · doi:10.1039/c1ib00043h · Cited by 284
Fuchs endothelial corneal dystrophy: The vicious cycle of Fuchs pathogenesis
Ong Tone, S., Kocaba, V., Böhm, M., Wylegala, A., White, T. L., & Jurkunas, U. V. (2021) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2020.100863 · Cited by 284
Metadata
- Authors
- Last, J. A., Liliensiek, S. J., Nealey, P. F., & Murphy, C. J.
- Venue
- Journal of Structural Biology
- Publisher
- Elsevier BV
- Published
- 2009-07
- Volume
- 167
- Issue
- 1
- Pages
- 19-24
- ISSN
- 1047-8477 (ISSN-L)
- OpenAlex
- W2105251832
- Cited by
- 222
- References
- 3
- FWCI
- 3.90
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determining the mechanical properties of human corneal basement membranes with atomic force microscopy. https://app.cochat.ai/papers/10.1016/j.jsb.2009.03.012
- The paper
- Last, J. A., Liliensiek, S. J., Nealey, P. F., & Murphy, C. J. (2009). Determining the mechanical properties of human corneal basement membranes with atomic force microscopy. Journal of Structural Biology. https://doi.org/10.1016/j.jsb.2009.03.012
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.