The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Dynamo: A flexible, user-friendly development tool for subtomogram averaging of cryo-EM data in high-performance computing environments
Open accessAbstract
Dynamo is a new software package for subtomogram averaging of cryo Electron Tomography (cryo-ET) data with three main goals: first, Dynamo allows user-transparent adaptation to a variety of high-performance computing platforms such as GPUs or CPU clusters. Second, Dynamo implements user-friendliness through GUI interfaces and scripting resources. Third, Dynamo offers user-flexibility through a plugin API. Besides the alignment and averaging procedures, Dynamo includes native tools for visualization and analysis of results and data, as well as support for third party visualization software, such as Chimera UCSF or EMAN2. As a demonstration of these functionalities, we studied bacterial flagellar motors and showed automatically detected classes with absent and present C-rings. Subtomogram averaging is a common task in current cryo-ET pipelines, which requires extensive computational resources and follows a well-established workflow. However, due to the data diversity, many existing packages offer slight variations of the same algorithm to improve results. One of the main purposes behind Dynamo is to provide explicit tools to allow the user the insertion of custom designed procedures - or plugins - to replace or complement the native algorithms in the different steps of the processing pipeline for subtomogram averaging without the burden of handling parallelization. Custom scripts that implement new approaches devised by the user are integrated into the Dynamo data management system, so that they can be controlled by the GUI or the scripting capacities. Dynamo executables do not require licenses for third party commercial software. Sources, executables and documentation are freely distributed on http://www.dynamo-em.org.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
UCSF Chimera—A visualization system for exploratory research and analysis
Pettersen, E. F., Goddard, T. D., Huang, C. C., Couch, G. S., Greenblatt, D. M., Meng, E. C., & Ferrin, T. E. (2004) · Journal of Computational Chemistry · doi:10.1002/jcc.20084 · Cited by 45,828
Hierarchical Grouping to Optimize an Objective Function
Ward, J. H. (1963) · Journal of the American Statistical Association · doi:10.1080/01621459.1963.10500845 · Cited by 20,598
Computer Visualization of Three-Dimensional Image Data Using IMOD
Kremer, J. R., Mastronarde, D. N., & McIntosh, J. R. (1996) · Journal of Structural Biology · doi:10.1006/jsbi.1996.0013 · Cited by 5,611
EMAN2: An extensible image processing suite for electron microscopy
Tang, G., Peng, L., Baldwin, P. R., Mann, D. S., Jiang, W., Rees, I., & Ludtke, S. J. (2007) · Journal of Structural Biology · doi:10.1016/j.jsb.2006.05.009 · Cited by 2,994
Parallel programming in OpenMP
Chandra, R., Dagum, L., Kohr, D., Maydan, D. E., & McDonald, J. (2001) · Cited by 1,293
Gropp, W., & Lusk, E. (2001) · Beowulf Cluster Computing with Linux · doi:10.7551/mitpress/1556.003.0013 · Cited by 1,124
The Molecular Architecture of Axonemes Revealed by Cryoelectron Tomography
Nicastro, D., Schwartz, C., Pierson, J., Gaudette, R., Porter, M. E., & McIntosh, J. R. (2006) · Science · doi:10.1126/science.1128618 · Cited by 879
Macromolecular Architecture in Eukaryotic Cells Visualized by Cryoelectron Tomography
Medalia, O., Weber, I., Frangakis, A. S., Nicastro, D., Gerisch, G., & Baumeister, W. (2002) · Science · doi:10.1126/science.1076184 · Cited by 837
Molecular architecture of native HIV-1 gp120 trimers
Liu, J., Bartesaghi, A., Borgnia, M. J., Sapiro, G., & Subramaniam, S. (2008) · Nature · doi:10.1038/nature07159 · Cited by 816
STRUCTURAL STUDIES BY ELECTRON TOMOGRAPHY: From Cells to Molecules
Lučić, V., Förster, F., & Baumeister, W. (2005) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.73.011303.074112 · Cited by 702
Duncombe, P., Lebart, L., Morineau, A., & Warwick, K. M. (1985) · Journal of the Royal Statistical Society. Series A (General) · doi:10.2307/2981514 · Cited by 518
Nuclear Pore Complex Structure and Dynamics Revealed by Cryoelectron Tomography
Beck, M., Förster, F., Ecke, M., Plitzko, J. M., Melchior, F., Gerisch, G., Baumeister, W., & Medalia, O. (2004) · Science · doi:10.1126/science.1104808 · Cited by 500
Tatebe, O. (1998) · Cited by 471
TOM software toolbox: acquisition and analysis for electron tomography
Nickell, S., Förster, F., Linaroudis, A., Net, W. D., Beck, F., Hegerl, R., Baumeister, W., & Plitzko, J. M. (2005) · Journal of Structural Biology · doi:10.1016/j.jsb.2004.10.006 · Cited by 448
Palenstijn, W. J., Batenburg, K. J., & Sijbers, J. (2011) · Journal of Structural Biology · doi:10.1016/j.jsb.2011.07.017 · Cited by 384
Structure and assembly of immature HIV
Briggs, J. A. G., Riches, J. D., Glass, B., Bartonova, V., Zanetti, G., & Kräusslich, H.-G. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0903535106 · Cited by 368
(2006) · doi:10.1007/978-0-387-69008-7 · Cited by 357
The molecular architecture of cadherins in native epidermal desmosomes
Al-Amoudi, A., Díez, D. C., Betts, M. J., & Frangakis, A. S. (2007) · Nature · doi:10.1038/nature05994 · Cited by 278
The native 3D organization of bacterial polysomes
Brandt, F., Etchells, S. A., Ortiz, J. O., Elcock, A. H., Hartl, F. U., & Baumeister, W. (2009) · Cell · doi:10.1016/j.cell.2008.11.016 · Cited by 258
CTF determination and correction for low dose tomographic tilt series
Xiong, Q., Morphew, M. K., Schwartz, C. L., Hoenger, A. H., & Mastronarde, D. N. (2009) · Journal of Structural Biology · doi:10.1016/j.jsb.2009.08.016 · Cited by 225
Clustering and variance maps for cryo-electron tomography using wedge-masked differences
Heumann, J. M., Hoenger, A., & Mastronarde, D. N. (2011) · Journal of Structural Biology · doi:10.1016/j.jsb.2011.05.011 · Cited by 220
CTF determination and correction in electron cryotomography
Fernández, J. J., Li, S., & Crowther, R. A. (2006) · Ultramicroscopy · doi:10.1016/j.ultramic.2006.02.004 · Cited by 188
3D reconstruction and processing of volumetric data in cryo-electron tomography
Winkler, H. (2007) · Journal of Structural Biology · doi:10.1016/j.jsb.2006.07.014 · Cited by 175
Classification and 3D averaging with missing wedge correction in biological electron tomography
Bartesaghi, A., Sprechmann, P., Liu, J., Randall, G., Sapiro, G., & Subramaniam, S. (2008) · Journal of Structural Biology · doi:10.1016/j.jsb.2008.02.008 · Cited by 175
Classification of cryo-electron sub-tomograms using constrained correlation
Förster, F., Pruggnaller, S., Seybert, A., & Frangakis, A. S. (2008) · Journal of Structural Biology · doi:10.1016/j.jsb.2007.07.006 · Cited by 174
Particle finding in electron micrographs using a fast local correlation algorithm
Roseman, A. M. (2003) · Ultramicroscopy · doi:10.1016/s0304-3991(02)00333-9 · Cited by 161
Computational resources for cryo-electron tomography in Bsoft
Heymann, J. B., Giovanni Cardone, A., Winkler, D. C., & Steven, A. C. (2007) · Journal of Structural Biology · doi:10.1016/j.jsb.2007.08.002 · Cited by 138
Winkler, H., Zhu, P., Liu, J., Ye, F., Roux, K. H., & Taylor, K. A. (2008) · Journal of Structural Biology · doi:10.1016/j.jsb.2008.10.004 · Cited by 135
Scheres, S. H. W., Melero, R., Valle, M., & Carazo, J. M. (2009) · Structure · doi:10.1016/j.str.2009.10.009 · Cited by 117
Performance evaluation of image processing algorithms on the GPU
Castaño‐Díez, D., Moser, D., Schönegger, A., Pruggnaller, S., & Frangakis, A. S. (2008) · Journal of Structural Biology · doi:10.1016/j.jsb.2008.07.006 · Cited by 107
Self-citationStructure Determination In Situ by Averaging of Tomograms
Förster, F. G., & Hegerl, R. (2007) · Methods in cell biology · doi:10.1016/s0091-679x(06)79029-x · Cited by 103
Structure of hibernating ribosomes studied by cryoelectron tomography in vitro and in situ
Ortiz, J. O., Brandt, F., Matias, V. R. F., Sennels, L., Rappsilber, J., Scheres, S. H. W., Eibauer, M., Hartl, F. U., & Baumeister, W. P. (2010) · The Journal of Cell Biology · doi:10.1083/jcb.201005007 · Cited by 92
Comparative cryo‐electron tomography of pathogenic Lyme disease spirochetes
Kudryashev, M., Cyrklaff, M., Baumeister, W. P., Simon, M. M., Wallich, R., & Frischknecht, F. (2009) · Molecular Microbiology · doi:10.1111/j.1365-2958.2009.06613.x · Cited by 86
Self-citationMethods for aligning and for averaging 3D volumes with missing data
Schmid, M. F., & Booth, C. R. (2007) · Journal of Structural Biology · doi:10.1016/j.jsb.2007.09.018 · Cited by 79
Xu, W., Xu, F., Jones, M., Keszthelyi, B., Sedat, J., Agard, D., & Mueller, K. (2010) · Journal of Structural Biology · doi:10.1016/j.jsb.2010.03.018 · Cited by 71
Implementation and performance evaluation of reconstruction algorithms on graphics processors
Castaño Díez, D., Mueller, H., & Frangakis, A. S. (2007) · Journal of Structural Biology · doi:10.1016/j.jsb.2006.08.010 · Cited by 68
Self-citationMaximum likelihood based classification of electron tomographic data
Stölken, M., Beck, F., Haller, T., et al. (2010) · Journal of Structural Biology · doi:10.1016/j.jsb.2010.08.005 · Cited by 66
Fast 3D motif search of EM density maps using a locally normalized cross-correlation function
Rath, B. K., Hegerl, R., Leith, A. G., et al. (2003) · Journal of Structural Biology · doi:10.1016/j.jsb.2003.09.029 · Cited by 55
High performance computing in structural determination by electron cryomicroscopy
Fernández, J. (2008) · Journal of Structural Biology · doi:10.1016/j.jsb.2008.07.005 · Cited by 49
Li, X., Grigorieff, N., & Cheng, Y. (2010) · Journal of Structural Biology · doi:10.1016/j.jsb.2010.06.010 · Cited by 45
Parallel, distributed and GPU computing technologies in single-particle electron microscopy
Schmeisser, M., Heisen, B. C., Luettich, M., Busche, B., Hauer, F., Koske, T., Knauber, K.-H., & Stark, H. (2009) · Acta Crystallographica Section D Biological Crystallography · doi:10.1107/s0907444909011433 · Cited by 44
An adaptive Expectation–Maximization algorithm with GPU implementation for electron cryomicroscopy
Tagare, H. D., Barthel, A., & Sigworth, F. J. (2010) · Journal of Structural Biology · doi:10.1016/j.jsb.2010.06.004 · Cited by 33
Subtomogram alignment by adaptive Fourier coefficient thresholding
Amat, F., Comolli, L. R., Moussavi, F., Smit, J., Downing, K. H., & Horowitz, M. (2010) · Journal of Structural Biology · doi:10.1016/j.jsb.2010.05.013 · Cited by 31
Single-particle electron cryotomography (cryoET)
Schmid, M. F. (2011) · Advances in protein chemistry and structural biology · doi:10.1016/b978-0-12-386507-6.00002-6 · Cited by 26
Zhang, X., Zhang, X., & Zhou, Z. H. (2010) · Journal of Structural Biology · doi:10.1016/j.jsb.2010.05.006 · Cited by 23
A distributed multi-GPU system for high speed electron microscopic tomographic reconstruction
Zheng, S. Q., Branlund, E., Kesthelyi, B., Braunfeld, M. B., Cheng, Y., Sedat, J. W., & Agard, D. A. (2011) · Ultramicroscopy · doi:10.1016/j.ultramic.2011.03.015 · Cited by 13
Assessing the benefits of focal pair cryo-electron tomography
Kudryashev, M., Stahlberg, H., & Castaño‐Díez, D. (2011) · Journal of Structural Biology · doi:10.1016/j.jsb.2011.10.004 · Cited by 10
Self-citation
Cited by
Molecular Architecture of the SARS-CoV-2 Virus
Yao, H., Song, Y., Chen, Y., Wu, N., Xu, J., Sun, C., Zhang, J., Weng, T., Zhang, Z., Wu, Z., et al. (2020) · Cell · doi:10.1016/j.cell.2020.09.018 · Cited by 1,060
“List of Supplementary Materials: Materials and Methods Figures S1-S5 Tables S1 References (41-58)”
BackgroundSARS-CoV-2 structure and replication characterized by in situ cryo-electron tomography
Klein, S., Cortese, M., Winter, S. L., Wachsmuth-Melm, M., Neufeldt, C. J., Cerikan, B., Stanifer, M. L., Boulant, S., Bartenschlager, R., & Chlanda, P. (2020) · Nature Communications · doi:10.1038/s41467-020-19619-7 · Cited by 731
A molecular pore spans the double membrane of the coronavirus replication organelle
Wolff, G., Limpens, R. W. A. L., Zevenhoven-Dobbe, J. C., Laugks, U., Zheng, S., de Jong, A. W. M., Koning, R. I., Agard, D. A., Grünewald, K., Koster, A. J., et al. (2020) · Science · doi:10.1126/science.abd3629 · Cited by 527
AI-based structure prediction empowers integrative structural analysis of human nuclear pores
Mosalaganti, S., Obarska-Kosinska, A., Siggel, M., Taniguchi, R., Turoňová, B., Zimmerli, C. E., Buczak, K., Schmidt, F. H., Margiotta, E., Mackmull, M.-T., et al. (2022) · Science · doi:10.1126/science.abm9506 · Cited by 355
A Bayesian approach to single-particle electron cryo-tomography in RELION-4.0
Zivanov, J., Otón, J., Ke, Z., von Kügelgen, A., Pyle, E., Qu, K., Morado, D., Castaño-Díez, D., Zanetti, G., Bharat, T. A., et al. (2022) · eLife · doi:10.7554/elife.83724 · Cited by 339
Metadata
- Authors
- Castaño-Díez, D., Kudryashev, M., Arheit, M., & Stahlberg, H.
- Venue
- Journal of Structural Biology
- Publisher
- Elsevier BV
- Published
- 2012-05
- Volume
- 178
- Issue
- 2
- Pages
- 139-151
- ISSN
- 1047-8477 (ISSN-L)
- OpenAlex
- W2051555473
- Cited by
- 509
- References
- 47
- FWCI
- 5.24
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.