The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Implementation of a cryo-electron tomography tilt-scheme optimized for high resolution subtomogram averaging
Open accessAbstract
Cryo-electron tomography (cryoET) allows 3D structural information to be obtained from cells and other biological samples in their close-to-native state. In combination with subtomogram averaging, detailed structures of repeating features can be resolved. CryoET data is collected as a series of images of the sample from different tilt angles; this is performed by physically rotating the sample in the microscope between each image. The angles at which the images are collected, and the order in which they are collected, together are called the tilt-scheme. Here we describe a "dose-symmetric tilt-scheme" that begins at low tilt and then alternates between increasingly positive and negative tilts. This tilt-scheme maximizes the amount of high-resolution information maintained in the tomogram for subsequent subtomogram averaging, and may also be advantageous for other applications. We describe implementation of the tilt-scheme in combination with further data-collection refinements including setting thresholds on acceptable drift and improving focus accuracy. Requirements for microscope set-up are introduced, and a macro is provided which automates the application of the tilt-scheme within SerialEM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Structure of the immature HIV-1 capsid in intact virus particles at 8.8 Å resolution
Schur, F. K. M., Hagen, W. J. H., Rumlová, M., Ruml, T., Müller, B., Kräusslich, H.-G., & Briggs, J. A. G. (2015) · Nature · doi:10.1038/nature13838 · Cited by 296
Self-citationSchur, F. K. M., Hagen, W. J. H., de Marco, A., & Briggs, J. A. G. (2013) · Journal of Structural Biology · doi:10.1016/j.jsb.2013.10.015 · Cited by 90
Self-citation
Cited by
Real-time cryo-electron microscopy data preprocessing with Warp
Tegunov, D., & Cramer, P. (2019) · Nature Methods · doi:10.1038/s41592-019-0580-y · Cited by 1,332
Structures and distributions of SARS-CoV-2 spike proteins on intact virions
Ke, Z., Oton, J., Qu, K., Cortese, M., Zila, V., McKeane, L., Nakane, T., Zivanov, J., Neufeldt, C. J., Cerikan, B., et al. (2020) · Nature · doi:10.1038/s41586-020-2665-2 · Cited by 1,149
Self-citationMolecular Architecture of the SARS-CoV-2 Virus
Yao, H., Song, Y., Chen, Y., Wu, N., Xu, J., Sun, C., Zhang, J., Weng, T., Zhang, Z., Wu, Z., et al. (2020) · Cell · doi:10.1016/j.cell.2020.09.018 · Cited by 1,060
“361 sets of tilt-series data were collected using the dose-symmetric scheme (Hagen et al., 2017) from 60 to 60 at 3 steps and at various defocus between 1.”
MethodGuillén-Boixet, J., Kopach, A., Holehouse, A. S., Wittmann, S., Jahnel, M., Schlüßler, R., Kim, K., Trussina, I. R. E. A., Wang, J., Mateju, D., et al. (2020) · Cell · doi:10.1016/j.cell.2020.03.049 · Cited by 865
SARS-CoV-2 structure and replication characterized by in situ cryo-electron tomography
Klein, S., Cortese, M., Winter, S. L., Wachsmuth-Melm, M., Neufeldt, C. J., Cerikan, B., Stanifer, M. L., Boulant, S., Bartenschlager, R., & Chlanda, P. (2020) · Nature Communications · doi:10.1038/s41467-020-19619-7 · Cited by 731
Metadata
- Authors
- Hagen, W. J. H., Wan, W., & Briggs, J. A. G.
- Venue
- Journal of Structural Biology
- Publisher
- Elsevier BV
- Published
- 2017-02
- Volume
- 197
- Issue
- 2
- Pages
- 191-198
- ISSN
- 1047-8477 (ISSN-L)
- OpenAlex
- W2427061751
- Cited by
- 806
- References
- 2
- FWCI
- 13.86
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.