Intraoperative Near Infrared Fluorescence Guided Identification of the Ureters Using Low Dose Methylene Blue: A First in Human Experience
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
PURPOSE: Near infrared fluorescence imaging is a promising technique that offers real-time visual information during surgery. In this study we report the first clinical results to our knowledge of ureteral imaging using near infrared fluorescence after a simple peripheral infusion of methylene blue. Furthermore, we assessed the optimal timing and dose of methylene blue. MATERIALS AND METHODS: A total of 12 patients who underwent lower abdominal surgery were included in this prospective feasibility study. Near infrared fluorescence imaging was performed using the Mini-FLARE™ imaging system. To determine optimal timing and dose, methylene blue was injected intravenously at doses of 0.25, 0.5 or 1 mg/kg after exposure of the ureters. Imaging was performed for up to 60 minutes after injection. RESULTS: In all patients both ureters could be clearly visualized within 10 minutes after infusion of methylene blue. The signal lasted at least up to 60 minutes after injection. The mean signal-to-background ratio of the ureter was 2.27 ± 1.22 (4), 2.61 ± 1.88 (4) and 3.58 ± 3.36 (4) for the 0.25, 0.5 and 1 mg/kg groups, respectively. A mixed model analysis was used to compare signal-to-background ratios among dose groups and times, and to assess the relationship between dose and time. A significant difference among time points (p <0.001) was found. However, no difference was observed among dose groups (p = 0.811). CONCLUSIONS: This study demonstrates the first successful use of near infrared fluorescence using low dose methylene blue for the identification of the ureters during lower abdominal surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Schaafsma, B. E., Mieog, J. S. D., Hutteman, M., van der Vorst, J. R., Kuppen, P. J. K., Löwik, C. W. G. M., Frangioni, J. V., van de Velde, C. J. H., & Vahrmeijer, A. L. (2011) · Journal of Surgical Oncology · doi:10.1002/jso.21943 · Cited by 816
Self-citationNew Technologies for Human Cancer Imaging
Frangioni, J. V. (2008) · Journal of Clinical Oncology · doi:10.1200/jco.2007.14.3065 · Cited by 800
Self-citationImage-Guided Surgery Using Invisible Near-Infrared Light: Fundamentals of Clinical Translation
Gioux, S., Choi, H. S., & Frangioni, J. V. (2010) · Molecular Imaging · doi:10.2310/7290.2010.00034 · Cited by 599
Self-citationFluorescent cholangiography illuminating the biliary tree during laparoscopic cholecystectomy
Ishizawa, T., Bandai, Y., Ijichi, M., Kaneko, J., Hasegawa, K., & Kokudo, N. (2010) · British Journal of Surgery · doi:10.1002/bjs.7125 · Cited by 381
van der Poel, H. G., Buckle, T., Brouwer, O. R., Valdés Olmos, R. A., & van Leeuwen, F. W. B. (2011) · European Urology · doi:10.1016/j.eururo.2011.03.024 · Cited by 334
Optical Image-guided Surgery—Where Do We Stand?
Keereweer, S., Kerrebijn, J. D. F., van Driel, P. B. A. A., Xie, B., Kaijzel, E. L., Snoeks, T. J. A., Que, I., Hutteman, M., van der Vorst, J. R., Mieog, J. S. D., et al. (2010) · Molecular Imaging and Biology · doi:10.1007/s11307-010-0373-2 · Cited by 318
Self-citationMieog, J. S. D., Troyan, S. L., Hutteman, M., Donohoe, K. J., van der Vorst, J. R., Stockdale, A., Liefers, G.-J., Choi, H. S., Gibbs-Strauss, S. L., Putter, H., et al. (2011) · Annals of Surgical Oncology · doi:10.1245/s10434-011-1566-x · Cited by 249
Self-citationProphylactic ureteral catheterization in gynecologic surgery
Kuno, K., Menzin, A. W., Kauder, H. H., Sison, C. P., & Gal, D. (1998) · Urology · doi:10.1016/s0090-4295(98)00382-3 · Cited by 157
Real-time, near-infrared, fluorescence-guided identification of the ureters using methylene blue
Matsui, A., Tanaka, E., Choi, H. S., Kianzad, V., Gioux, S., Lomnes, S. J., & Frangioni, J. V. (2010) · Surgery · doi:10.1016/j.surg.2009.12.003 · Cited by 157
Self-citationJeschke, S. W., Lusuardi, L., Myatt, A., Hruby, S., Pirich, C., & Janetschek, G. (2012) · Urology · doi:10.1016/j.urology.2012.05.050 · Cited by 122
Optical Imaging of Kidney Cancer with Novel Near Infrared Heptamethine Carbocyanine Fluorescent Dyes
Yang, X., Shao, C., Wang, R., et al. (2012) · The Journal of Urology · doi:10.1016/j.juro.2012.09.056 · Cited by 92
Optical diagnostics in urology: current applications and future prospects
Crow, P., Stone, N., Kendall, C. A., Persad, R. A., & Wright, M. (2003) · British Journal of Urology · doi:10.1046/j.1464-410x.2003.04368.x · Cited by 58
Rowe, C. K., Franco, F. B., Barbosa, J. A. B. A., Minnillo, B. J., Chow, J. S., Treves, S. T., Retik, A. B., & Nguyen, H. T. (2012) · The Journal of Urology · doi:10.1016/j.juro.2012.07.002 · Cited by 15
Cited by
Near-infrared fluorophores for biomedical imaging
Hong, G., Antaris, A. L., & Dai, H. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0010 · Cited by 2,985
Image-guided cancer surgery using near-infrared fluorescence
Vahrmeijer, A. L., Hutteman, M., van der Vorst, J. R., van de Velde, C. J. H., & Frangioni, J. V. (2013) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2013.123 · Cited by 1,466
Self-citationLi, B., Lu, L., Zhao, M., Lei, Z., & Zhang, F. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201801226 · Cited by 658
Donor Engineering for NIR-II Molecular Fluorophores with Enhanced Fluorescent Performance
Yang, Q., Hu, Z., Zhu, S., Ma, R., Ma, H., Ma, Z., Wan, H., Zhu, T., Jiang, Z., Liu, W., et al. (2018) · Journal of the American Chemical Society · doi:10.1021/jacs.7b10334 · Cited by 554
NIR-II nanoprobes in-vivo assembly to improve image-guided surgery for metastatic ovarian cancer
Wang, P., Fan, Y., Lu, L., Liu, L., Fan, L., Zhao, M., Xie, Y., Xu, C., & Zhang, F. (2018) · Nature Communications · doi:10.1038/s41467-018-05113-8 · Cited by 451
Metadata
- Authors
- Verbeek, F. P. R., van der Vorst, J. R., Schaafsma, B. E., Swijnenburg, R.-J., Gaarenstroom, K. N., Elzevier, H. W., van de Velde, C. J. H., Frangioni, J. V., & Vahrmeijer, A. L.
- Venue
- Journal of Urology
- Published
- 2013-08
- Volume
- 190
- Issue
- 2
- Pages
- 574-579
- ISSN
- 0022-5347 (ISSN-L)
- 1527-3792
- OpenAlex
- W2144603071
- Cited by
- 176
- References
- 13
- FWCI
- 8.08
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.