CoChat

Near-instant noninvasive optical imaging of tissue perfusion for vascular assessment

Open access
Weinkauf, Craig, Mazhar, Amaan, Vaishnav, Kairavi, Hamadani, Auon A., Cuccia, David J., Armstrong, David G. · 2019 · Journal of Vascular Surgery
Cited by 43

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Background Noninvasive vascular tests are critical for identifying patients who may benefit from surgical revascularization, but current tests have significant limitations in people with diabetes. This study aimed to evaluate the ability of spatial frequency domain imaging (SFDI), an optical imaging method capable of measuring tissue oxygen saturation (StO2) and tissue hemoglobin, to assess lower extremity blood supply. Methods Ankle‐brachial index, toe‐brachial index, pedal Doppler waveforms, and SFDI images were prospectively evaluated in 47 consecutive patients with and without diabetes in whom there was concern for peripheral artery disease (PAD). SFDI is a noncontact optical imaging technology that uses structured illumination to quantify subsurface (2‐3 mm in depth) StO2 and tissue hemoglobin in the dermal microcirculation (HbT1) and macrocirculation (HbT2) over a large field of view (15 × 20 cm) within 10 seconds. Results This demonstrates the ability of SFDI to capture reliable clinical measurements of perfusion in plantar aspects of the feet. SFDI StO2 values differentiate nondiabetic patients with and without arterial disease, defined as ankle‐brachial index <0.9 (P = .06), but are limited in those with diabetes (P = .43). An elevated StO2 and reduced HbT1 are observed in people with diabetes compared with nondiabetic patients (P < .05). An SFDI‐derived HbT2/HbT1 index differentiates diabetics with PAD vs no PAD (P < .01) using toe‐brachial index <0.7 as a cutoff for PAD in diabetes. Conclusions SFDI is a feasible, rapid, and easy to use widefield measurement of perfusion in a clinical setting. This first‐of‐use study suggests that the technology has potential to evaluate lower extremity perfusion in people with and without diabetes. Further studies with increased numbers of patients and end points including wound healing will need to be designed to fully evaluate the applicability of this new technology.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jvs.2018.06.202

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 43

Metadata

Authors
Weinkauf, C., Mazhar, A., Vaishnav, K., Hamadani, A. A., Cuccia, D. J., & Armstrong, D. G.
Venue
Journal of Vascular Surgery
Publisher
Elsevier BV
Published
2019-02
Volume
69
Issue
2
Pages
555-562
ISSN
0741-5214 (ISSN-L)
OpenAlex
W2895504540
Cited by
43
References
4
FWCI
3.31
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.