Spatial frequency domain imaging in 2019: principles, applications, and perspectives
Open accessThe DOI matches its Crossref record; 76 of the 76 references it cites were found in a registry or an index.
Abstract
Spatial frequency domain imaging (SFDI) has witnessed very rapid growth over the last decade, owing to its unique capabilities for imaging optical properties and chromophores over a large field-of-view and in a rapid manner. We provide a comprehensive review of the principles of this imaging method as of 2019, review the modeling of light propagation in this domain, describe acquisition methods, provide an understanding of the various implementations and their practical limitations, and finally review applications that have been published in the literature. Importantly, we also introduce a group effort by several key actors in the field for the dissemination of SFDI, including publications, advice in hardware and implementations, and processing code, all freely available online.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MCML—Monte Carlo modeling of light transport in multi-layered tissues
Wang, L., Jacques, S. L., & Zheng, L. (1995) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(95)01640-f · Cited by 3,324
Review of tissue simulating phantoms for optical spectroscopy, imaging and dosimetry
Pogue, B. W., & Patterson, M. S. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2335429 · Cited by 837
Quantitation and mapping of tissue optical properties using modulated imaging
Cuccia, D. J., Bevilacqua, F., Durkin, A. J., Ayers, F. R., & Tromberg, B. J. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3088140 · Cited by 655 · cited 8×
“In particular, these instrumental factors can limit the frequency range used, as the signal-to-noise ratio greatly decreases with spatial frequency.(1,39) Although the specific requirements of tolerances will depend on the objectives of a specific project, in general data should be as clean and noise-free as possible…”
BackgroundMethodInfluentialSelf-citationCuccia, D. J., Bevilacqua, F., Durkin, A. J., & Tromberg, B. J. (2005) · Optics Letters · doi:10.1364/ol.30.001354 · Cited by 429 · cited 2×
“43 Images with depth-sensitive contrast can then be generated using the recovered diffuse reflectance and knowing the spatial frequency used.”
BackgroundMethodSelf-citationNoninvasive determination of the optical properties of two-layered turbid media
Kienle, A., Patterson, M. S., Dögnitz, N., Bays, R., Wagnières, G., & van den Bergh, H. (1998) · Applied Optics · doi:10.1364/ao.37.000779 · Cited by 294
First-in-human pilot study of a spatial frequency domain oxygenation imaging system
Gioux, S., Stockdale, A., Oketokoun, R., Ashitate, Y., Durr, N. J., Moffitt, L. A., Frangioni, J. V., Mazhar, A., Tromberg, B. J., Durkin, A. J., et al. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3614566 · Cited by 166 · cited 3×
“For instance, it has been demonstrated that choosing 650 and 860 nm was optimal to determine oxyhemoglobin and deoxyhemoglobin concentrations.(14,66) It should be noted that this method typically measures what is referred to as “tissue molar concentration,” noted with the prefix “ct” (e.”
MethodSelf-citationThree-dimensional surface profile intensity correction for spatially modulated imaging
Gioux, S., Mazhar, A., Cuccia, D. J., Durkin, A. J., Tromberg, B. J., & Frangioni, J. V. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3156840 · Cited by 161 · cited 4×
“These systems are a combination of benchtop imaging systems with some being transportable to preclinical or clinical sites, as well as improved methods for robust measurement during clinical conditions [motion correction and three-dimensional (3-D) correction].(26,27) 2.”
BackgroundMethodInfluentialSelf-citationKonecky, S. D., Mazhar, A., Cuccia, D. J., Durkin, A. J., Schotland, J. C., & Tromberg, B. J. (2009) · Optics Express · doi:10.1364/oe.17.014780 · Cited by 140
Self-citationWavelength optimization for rapid chromophore mapping using spatial frequency domain imaging
Mazhar, A., Dell, S., Cuccia, D. J., Gioux, S., Durkin, A. J., Frangioni, J. V., & Tromberg, B. J. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3523373 · Cited by 136 · cited 1×
“For instance, it has been demonstrated that choosing 650 and 860 nm was optimal to determine oxyhemoglobin and deoxyhemoglobin concentrations.(14,66) It should be noted that this method typically measures what is referred to as “tissue molar concentration,” noted with the prefix “ct” (e.”
MethodSelf-citationIn Vivo Multiphoton NADH Fluorescence Reveals Depth-Dependent Keratinocyte Metabolism in Human Skin
Balu, M., Mazhar, A., Hayakawa, C. K., Mittal, R., Krasieva, T. B., König, K., Venugopalan, V., & Tromberg, B. J. (2013) · Biophysical Journal · doi:10.1016/j.bpj.2012.11.3809 · Cited by 133
Self-citation
Cited by
Ortega, S., Halicek, M., Fabelo, H., Callico, G. M., & Fei, B. (2020) · Biomedical Optics Express · doi:10.1364/boe.386338 · Cited by 170
“Additionally, Spatial Frequency Domain Imaging (SFDI) make use of modulated light sources and light transport models to extract information about absorption and scattering about different tissues, which can be subsequently used for diagnosis [9].”
MethodSetchfield, K., Gorman, A., Simpson, A. H. R. W., Somekh, M. G., & Wright, A. J. (2023) · Biomedical Optics Express · doi:10.1364/boe.493588 · Cited by 49
Metadata
- Authors
- Gioux, S., Mazhar, A., & Cuccia, D. J.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2019-06-20
- Volume
- 24
- Issue
- 07
- Pages
- 1
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2952818417
- Cited by
- 158
- References
- 76
- FWCI
- 11.25
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spatial frequency domain imaging in 2019: principles, applications, and perspectives. https://app.cochat.ai/papers/10.1117/1.jbo.24.7.071613
- The paper
- Gioux, S., Mazhar, A., & Cuccia, D. J. (2019). Spatial frequency domain imaging in 2019: principles, applications, and perspectives. Journal of Biomedical Optics. https://doi.org/10.1117/1.jbo.24.7.071613
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.