Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 203

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Removal mechanism of heavy metal (Cu, Ni, Zn, and Cr) in the presence of cyanide during electrocoagulation using Fe and Al electrodes

Kim, Taeyeon, Kim, Tae-Kyoung, Zoh, Kyung-Duk · 2020 · Journal of Water Process Engineering

Abstract

Abstract Heavy metals have frequently been detected in metal plating wastewater. In this study, electrocoagulation method using iron (Fe) and aluminum (Al) electrodes was applied to simultaneously remove four heavy metals (Cu, Ni, Zn, Cr) in artificial metal plating wastewater. The Fe electrode showed greater removal efficiency for especially Cr than did the Al electrode due to the reduction of Cr6+ ion by Fe2+ ions produced from electrode. Alkaline pH favored electrocoagulation because of the abundance of hydroxide (OH−) ions; thus, metal hydroxides can be formed readily under alkaline pH. The metal removal increased with current density, as Fe2+ ion was generated more effectively at high current. However, the electrolyte concentration did not significantly affect metal removal efficiency. In electrocoagulation experiments using Fe electrodes, the mass of sludge formed was 0.68–2.50 kg/m3 and the amount of energy consumed was 0.37–2.78 kW h/m3, respectively, during the treatment of artificial metal plating wastewater containing four heavy metals in the absence of cyanide, which increased to 3.64–4.74 kg/m3 and 4.80–5.04 kW h/m3 for artificial wastewater in the presence of cyanide. The FTIR spectra of the sludge samples generated when using Fe and Al electrodes showed that all four metals exhibited OH stretching peaks, implying that main removal mechanism of metals during electrocoagulation is the precipitation with metal hydroxide. Iron sludge was composed mainly of Fe3O4 and FeO(OH), and Al sludge was mostly AlO(OH). When using Fe electrode in the presence of cyanide, cyanide was also adsorbed onto iron sludge via Fe-CN bonding.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jwpe.2019.101109

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 203

Metadata

Authors
Kim, T., Kim, T.-K., & Zoh, K.-D.
Venue
Journal of Water Process Engineering
Publisher
Elsevier BV
Published
2020-02
Volume
33
Pages
101109
ISSN
2214-7144 (ISSN-L)
OpenAlex
W2995529317
Cited by
203
References
6
FWCI
7.92
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Removal mechanism of heavy metal (Cu, Ni, Zn, and Cr) in the presence of cyanide during electrocoagulation using Fe and Al electrodes. https://app.cochat.ai/papers/10.1016/j.jwpe.2019.101109
The paper
Kim, T., Kim, T.-K., & Zoh, K.-D. (2020). Removal mechanism of heavy metal (Cu, Ni, Zn, and Cr) in the presence of cyanide during electrocoagulation using Fe and Al electrodes. Journal of Water Process Engineering. https://doi.org/10.1016/j.jwpe.2019.101109

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.