An ensemble-based system for automatic screening of diabetic retinopathy
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
In this paper, an ensemble-based method for the screening of diabetic retinopathy (DR) is proposed. This approach is based on features extracted from the output of several retinal image processing algorithms, such as image-level (quality assessment, pre-screening, AM/FM), lesion-specific (microaneurysms, exudates) and anatomical (macula, optic disk) components. The actual decision about the presence of the disease is then made by an ensemble of machine learning classifiers. We have tested our approach on the publicly available Messidor database, where 90% sensitivity, 91% specificity and 90% accuracy and 0.989 AUC are achieved in a disease/no-disease setting. These results are highly competitive in this field and suggest that retinal image processing is a valid approach for automatic DR screening.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Combining Pattern Classifiers: Methods and Algorithms
Kuncheva, L. I. (2004) · Wiley eBooks · doi:10.1002/0471660264 · Cited by 3,005
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
Classifier selection for majority voting
Ruta, D., & Gabrys, B. (2005) · Information Fusion · doi:10.1016/j.inffus.2004.04.008 · Cited by 630
An Ensemble-Based System for Microaneurysm Detection and Diabetic Retinopathy Grading
Antal, B., & Hajdu, A. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2193126 · Cited by 335
Self-citationAutomated Early Detection of Diabetic Retinopathy
Abràmoff, M. D., Reinhardt, J. M., Russell, S. R., Folk, J. C., Mahajan, V. B., Niemeijer, M., & Quellec, G. (2010) · Ophthalmology · doi:10.1016/j.ophtha.2010.03.046 · Cited by 287
Abràmoff, M. D., Niemeijer, M., Suttorp-Schulten, M. S. A., Viergever, M. A., Russell, S. R., & van Ginneken, B. (2008) · Diabetes Care · doi:10.2337/dc07-1312 · Cited by 277
Multiscale AM-FM Methods for Diabetic Retinopathy Lesion Detection
Agurto, C., Murray, V., Barriga, E., Murillo, S., Pattichis, M., Davis, H., Russell, S., Abramoff, M., & Soliz, P. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2037146 · Cited by 259
Philip, S., Fleming, A. D., Goatman, K. A., Fonseca, S., Mcnamee, P., Scotland, G. S., Prescott, G. J., Sharp, P. F., & Olson, J. A. (2007) · British Journal of Ophthalmology · doi:10.1136/bjo.2007.119453 · Cited by 225
Combining algorithms for automatic detection of optic disc and macula in fundus images
Qureshi, R. J., Kovács, L., Harangi, B., Nagy, B., Pető, T., & Hajdú, A. (2011) · Computer Vision and Image Understanding · doi:10.1016/j.cviu.2011.09.001 · Cited by 138
Eom, J.-H., Kim, S., & ZHANG, B. (2007) · Expert Systems with Applications · doi:10.1016/j.eswa.2007.04.015 · Cited by 132
Cited by
Automated Identification of Diabetic Retinopathy Using Deep Learning
Gargeya, R., & Leng, T. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2017.02.008 · Cited by 1,362
Analysis of Dimensionality Reduction Techniques on Big Data
Reddy, G. T., Reddy, M. P. K., Lakshmanna, K., Kaluri, R., Rajput, D. S., Srivastava, G., & Baker, T. (2020) · IEEE Access · doi:10.1109/access.2020.2980942 · Cited by 877
Leveraging uncertainty information from deep neural networks for disease detection
Leibig, C., Allken, V., Ayhan, M. S., Berens, P., & Wahl, S. (2017) · Scientific Reports · doi:10.1038/s41598-017-17876-z · Cited by 510
“We also performed similar ensembling 43,53 , by selecting an optimal (forward-backward search while monitoring AUC) ensemble of 100 networks from a much larger pool of dropout networks by controlling the random seeds.”
BackgroundMethodInfluentialLi, X., Hu, X., Yu, L., Zhu, L., Fu, C.-W., & Heng, P.-A. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2951844 · Cited by 449
IDRiD: Diabetic Retinopathy – Segmentation and Grading Challenge
Porwal, P., Pachade, S., Kokare, M., Deshmukh, G., Son, J., Bae, W., Liu, L., Wang, J., Liu, X., Gao, L., et al. (2020) · Medical Image Analysis · doi:10.1016/j.media.2019.101561 · Cited by 372
Self-citationEarly Detection of Diabetic Retinopathy Using PCA-Firefly Based Deep Learning Model
Gadekallu, T. R., Khare, N., Bhattacharya, S., Singh, S., Maddikunta, P. K. R., Ra, I.-H., & Alazab, M. (2020) · Electronics · doi:10.3390/electronics9020274 · Cited by 343
Deep neural networks to predict diabetic retinopathy
Gadekallu, T. R., Khare, N., Bhattacharya, S., Singh, S., Maddikunta, P. K. R., & Srivastava, G. (2023) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-020-01963-7 · Cited by 283
Ophthalmic diagnosis using deep learning with fundus images – A critical review
Sengupta, S., Singh, A., Leopold, H. A., Gulati, T., & Lakshminarayanan, V. (2020) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2019.101758 · Cited by 201
“[106] Ensemble Model Messidor 90% 90% 91% .”
Li, X., Pang, T., Xiong, B., Liu, W., Liang, P., & Wang, T. (2017) · 2017 10th International Congress on Image and Signal Processing, BioMedical Engineering and Informatics (CISP-BMEI) · doi:10.1109/cisp-bmei.2017.8301998 · Cited by 195
“[4] 91.”
Diabetic Retinopathy Diagnosis From Fundus Images Using Stacked Generalization of Deep Models
Kaushik, H., Singh, D., Kaur, M., Alshazly, H., Zaguia, A., & Hamam, H. (2021) · IEEE Access · doi:10.1109/access.2021.3101142 · Cited by 170
A comprehensive review of AI-Based detection of Arrhythmia using Electrocardiogram (ECG)
Ayyub, A., Politis, C., & Usman, M. A. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110594 · Cited by 18
Metadata
- Authors
- Antal, B., & Hajdu, A.
- Venue
- Knowledge-Based Systems
- Publisher
- Elsevier BV
- Published
- 2014-04
- Volume
- 60
- Pages
- 20-27
- ISSN
- 0950-7051 (ISSN-L)
- OpenAlex
- W2088422930
- Cited by
- 256
- References
- 19
- FWCI
- 9.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.