Automated detection of lung cancer at ultralow dose PET/CT by deep neural networks – Initial results

Schwyzer, Moritz, Ferraro, Daniela A., Muehlematter, Urs J., Curioni-Fontecedro, Alessandra, Huellner, Martin W., von Schulthess, Gustav K., Kaufmann, Philipp A., Burger, Irene A., Messerli, Michael · 2018 · Lung Cancer
Cited by 119

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVES We evaluated whether machine learning may be helpful for the detection of lung cancer in FDG-PET imaging in the setting of ultralow dose PET scans. MATERIALS AND METHODS We studied the performance of an artificial neural network discriminating lung cancer patients (n = 50) from controls (n = 50) without pulmonary malignancies. A total of 3936 PET slices including images in which the lung tumor is visually present and image slices of patients with no lung cancer were exported. The diagnostic performance of the artificial neural network based on clinical standard dose PET images (PET100%) as well as with a tenfold (PET10%) and thirtyfold (PET3.3%) reduced radiation dose (∼0.11 mSv) was assessed. RESULTS The area under the curve of the deep learning algorithm for lung cancer detection was 0.989, 0.983 and 0.970 for standard dose images (PET100%), and reduced dose PET10%, and PET3.3% reconstruction, respectively. The artificial neural network achieved a sensitivity of 95.9% and 91.5% and a specificity of 98.1% and 94.2%, at standard dose and ultralow dose PET3.3%, respectively. CONCLUSION Our results suggest that machine learning algorithms may aid fully automated lung cancer detection even at very low effective radiation doses of 0.11 mSv. Further improvement of this technology might improve the specificity of lung cancer screening efforts and could lead to new applications of FDG-PET.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.lungcan.2018.11.001

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 119

Metadata

Authors
Schwyzer, M., Ferraro, D. A., Muehlematter, U. J., Curioni-Fontecedro, A., Huellner, M. W., von Schulthess, G. K., Kaufmann, P. A., Burger, I. A., & Messerli, M.
Venue
Lung Cancer
Publisher
Elsevier BV
Published
2018-12
Volume
126
Pages
170-173
ISSN
0169-5002 (ISSN-L)
OpenAlex
W2899472973
Cited by
119
References
3
FWCI
7.64
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Automated detection of lung cancer at ultralow dose PET/CT by deep neural networks – Initial results. https://app.cochat.ai/papers/10.1016/j.lungcan.2018.11.001
The paper
Schwyzer, M., Ferraro, D. A., Muehlematter, U. J., Curioni-Fontecedro, A., Huellner, M. W., von Schulthess, G. K., Kaufmann, P. A., Burger, I. A., & Messerli, M. (2018). Automated detection of lung cancer at ultralow dose PET/CT by deep neural networks – Initial results. Lung Cancer. https://doi.org/10.1016/j.lungcan.2018.11.001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.