Cited by 73Medical Imaging Techniques and ApplicationsRadiation Dose and ImagingLung Cancer Diagnosis and Treatment

Impact of a Bayesian penalized likelihood reconstruction algorithm on image quality in novel digital PET/CT: clinical implications for the assessment of lung tumors

Open access
Messerli, Michael, Stolzmann, Paul, Egger-Sigg, Michèle, Trinckauf, Josephine, D’Aguanno, Stefano, Burger, Irene A., von Schulthess, Gustav K., Kaufmann, Philipp A. +1 more·2018·EJNMMI Physics

Abstract

The aim of this study was to evaluate and compare PET image reconstruction algorithms on novel digital silicon photomultiplier PET/CT in patients with newly diagnosed and histopathologically confirmed lung cancer. A total of 45 patients undergoing 18F-FDG PET/CT for initial lung cancer staging were included. PET images were reconstructed using ordered subset expectation maximization (OSEM) with time-of-flight and point spread function modelling as well as Bayesian penalized likelihood reconstruction algorithm (BSREM) with different β -values yielding a total of 7 datasets per patient. Subjective and objective image assessment with all image datasets was carried out, including subgroup analyses for patients with high dose (> 2.0 MBq/kg) and low dose (≤ 2.0 MBq/kg) of 18F-FDG injection regimen. Subjective image quality ratings were significantly different among all different reconstruction algorithms as well as among BSREM using different β -values only (both p < 0.001). BSREM with a β -value of 600 was assigned the highest score for general image quality, image sharpness, and lesion conspicuity. BSREM reconstructions resulted in higher SUV max of lung tumors compared to OSEM of up to + 28.0% ( p < 0.001). BSREM reconstruction resulted in higher signal-/ and contrast-to-background ratios of lung tumor and higher signal-/ and contrast-to-noise ratio compared to OSEM up to a β -value of 800. Lower β -values (BSREM 450 ) resulted in the best image quality for high dose 18F-FDG injections, whereas higher β -values (BSREM 600 ) lead to the best image quality in low dose 18F-FDG PET/CT ( p < 0.05). BSREM reconstruction algorithm used in digital detector PET leads to significant increases of lung tumor SUV max , signal-to-background ratio, and signal-to-noise ratio, which translates into a higher image quality, tumor conspicuity, and image sharpness.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1186/s40658-018-0223-x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Inter-method SUV differences may no longer be significant at beta values of 300 to 600, which have been rated as optimal for visual reading of [18F]FDG-PET images by human readers.

    “However, this difference is directly dependent on the user-defined penalization factor beta during PL reconstruction, and at beta values of 300 to 600, which have been rated as optimal for visual reading of [18F]FDG-PET images by human readers [107,112,113], inter-method SUV differences may no longer be significant [41,108,111].”

    From Influences on PET Quantification and Interpretation (2022) · cites this paper as [112]

    The Results report that readers preferred β values of 450 or 600, depending on FDG dose. But Table 5 in the Results shows that tumor SUVmax differed significantly between both OSEM reconstructions and BSREM at β values of 350, 450, and 600 (all p < 0.001). Thus, this paper does not support the claim that inter-method SUV differences may cease to be significant at those values. (LLM, conf=0.88)

    Experimental — accuracy not yet measured
  • In low-count conditions, the tendency to prefer smooth, low-noise images with beta values >600 over sharper images could become even more evident.

    “In low-count conditions, this tendency to prefer smooth, low-noise images with beta values >600 over “sharper” images could become even more evident [112,170].”

    From Influences on PET Quantification and Interpretation (2022) · cites this paper as [112]

    The Discussion and Results report that readers’ preferred reconstruction shifted from β=450 to β=600 in patients receiving lower 18F-FDG doses, consistent with a preference for greater noise control. They do not establish a preference for β values >600 in low-count conditions; the reported shift ends at 600. (LLM, conf=0.86)

    Experimental — accuracy not yet measured
  • Several studies on subjective image quality in whole-body [18F]FDG-PET with PL reconstruction found that image quality was highest at beta values of 450 (to 600) despite lower lesion contrast recovery or image sharpness at these beta values compared to lower values.

    “Several studies on subjective image quality in whole-body [18F]FDG-PET with PL reconstruction found that image quality was highest at beta values of 450 (to 600) despite lower lesion CR or “image sharpness” at these beta values compared to lower values [41,108,112,175,179].”

    From Influences on PET Quantification and Interpretation (2022) · cites this paper as [112]

    Split into 2 atoms — 1 confirmed, 1 partially supported, 0 disputed, 0 misattributed, 0 unverifiable. Expand the claim to see per-atom verdicts.

    Experimental — accuracy not yet measured
  • PL reconstruction has repeatedly been shown to increase conspicuity and detection rates of pulmonary lesions, even compared to OSEM with PSF and/or TOF.

    “PL reconstruction has repeatedly been shown to increase conspicuity and detection rates of pulmonary lesions, even compared to OSEM with PSF and/or TOF [112,113,164,173,174].”

    From Influences on PET Quantification and Interpretation (2022) · cites this paper as [112]

    The Discussion reports greater lung-tumor lesion conspicuity with BSREM (a penalized-likelihood reconstruction method) than with OSEM; the Methods specify OSEM comparisons using PSF and TOF. The paper reports image-quality ratings and tumor uptake, but does not establish higher pulmonary-lesion detection rates. Its single study also does not, by itself, establish the claim that this has been shown repeatedly. (LLM, conf=0.88)

    Experimental — accuracy not yet measured
  • Several authors have reported improved SNR and image quality with PL reconstruction for different radiopharmaceuticals, including [18F]FDG, [18F]F-PSMA-1007, [68Ga]Ga-PSMA-11, [68Ga]Ga-DOTATATE, and 89Zr-labelled tracers.

    “several authors have reported improved SNR and image quality with different radiopharmaceuticals, such as [18F]FDG [107,112,113], [18F]F-PSMA-1007 [143], [68Ga]Ga-PSMA-11 [169,170], [68Ga]Ga-DOTATATE [171] or 89Zr-labelled tracers [172].”

    From Influences on PET Quantification and Interpretation (2022) · cites this paper as [112]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 22

  1. [1]Siegel RL, Miller KD, Jemal A. Cancer statistics, 2018. CA Cancer J Clin. 2018; 10.3322/caac.21442. 29313949 · DOI
  2. [2]Hess S Blomberg BA Zhu HJ Hoilund-Carlsen PF Alavi A The pivotal role of FDG-PET/CT in modern medicine Acad Radiol 2014 21 232 249 10.1016/j.acra.2013.11.002 24439337 · DOI
  3. [3]Pieterman RM van Putten JW Meuzelaar JJ Preoperative staging of non-small-cell lung cancer with positron-emission tomography N Engl J Med 2000 343 254 261 10.1056/NEJM200007273430404 10911007 · DOI
  4. [4]Goeckenjan G Sitter H Thomas M Prevention, diagnosis, therapy, and follow-up of lung cancer Pneumologie 2010 64 Suppl 2 e1 164 10.1055/s-0029-1243837 20217630 · DOI
  5. [5]Naidich DP High-resolution computed tomography of the pulmonary parenchyma: past, present, and future? J Thorac Imaging 2010 25 32 33 10.1097/RTI.0b013e3181cc4de6 20160599 · DOI
  6. [6]Lardinois D Weder W Hany TF Staging of non-small-cell lung cancer with integrated positron-emission tomography and computed tomography N Engl J Med 2003 348 2500 2507 10.1056/NEJMoa022136 12815135 · DOI
  7. [7]Takamochi K Yoshida J Murakami K Pitfalls in lymph node staging with positron emission tomography in non-small cell lung cancer patients Lung Cancer 2005 47 235 242 10.1016/j.lungcan.2004.08.004 15639722 · DOI
  8. [8]Cheng K, Matthews J, Boellaard R. Improving the signal-to-noise ratio in static PET reconstruction using HYPR-OSEM. Nuclear Science Symposium, Medical Imaging Conference. 2017; 10.1109/NSSMIC.2016.8069454. · DOI
  9. [9]Lois C Jakoby BW Long MJ An assessment of the impact of incorporating time-of-flight information into clinical PET/CT imaging J Nucl Med 2010 51 237 245 10.2967/jnumed.109.068098 20080882 PMC2818518 · DOI
  10. [10]Boellaard R van Lingen A Lammertsma AA Experimental and clinical evaluation of iterative reconstruction (OSEM) in dynamic PET: quantitative characteristics and effects on kinetic modeling J Nucl Med 2001 42 808 817 11337581
  11. [11]Sah BR Stolzmann P Delso G Clinical evaluation of a block sequential regularized expectation maximization reconstruction algorithm in 18F-FDG PET/CT studies Nucl Med Commun 2017 38 57 66 10.1097/MNM.0000000000000604 27755394 · DOI
  12. [12]Baratto L Park SY Hatami N 18F-FDG silicon photomultiplier PET/CT: a pilot study comparing semi-quantitative measurements with standard PET/CT PLoS One 2017 12 e0178936 10.1371/journal.pone.0178936 28582472 PMC5459477 · DOI
  13. [13]Levin CS Maramraju SH Khalighi MM Deller TW Delso G Jansen F Design features and mutual compatibility studies of the time-of-flight PET capable GE SIGNA PET/MR system IEEE Trans Med Imaging 2016 35 1907 1914 10.1109/TMI.2016.2537811 26978664 · DOI
  14. [16]Ahn S Ross SG Asma E Quantitative comparison of OSEM and penalized likelihood image reconstruction using relative difference penalties for clinical PET Phys Med Biol 2015 60 5733 5751 10.1088/0031-9155/60/15/5733 26158503 · DOI
  15. [18]Everaert H Vanhove C Lahoutte T Optimal dose of 18F-FDG required for whole-body PET using an LSO PET camera Eur J Nucl Med Mol Imaging 2003 30 1615 1619 10.1007/s00259-003-1317-8 14504831 · DOI
  16. [19]Queiroz MA Delso G Wollenweber S Dose optimization in TOF-PET/MR compared to TOF-PET/CT PLoS One 2015 10 e0128842 10.1371/journal.pone.0128842 26147919 PMC4493146 · DOI
  17. [20]Detterbeck FC Boffa DJ Kim AW Tanoue LT The Eighth Edition Lung Cancer Stage Classification Chest 2017 151 193 203 10.1016/j.chest.2016.10.010 27780786 · DOI
  18. [21]Silvestri GA Gonzalez AV Jantz MA Methods for staging non-small cell lung cancer: diagnosis and management of lung cancer, 3rd ed: American College of Chest Physicians evidence-based clinical practice guidelines Chest 2013 143 e211S e250S 10.1378/chest.12-2355 23649440 · DOI
  19. [22]Akamatsu G Ishikawa K Mitsumoto K Improvement in PET/CT image quality with a combination of point-spread function and time-of-flight in relation to reconstruction parameters J Nucl Med 2012 53 1716 1722 10.2967/jnumed.112.103861 22952340 · DOI · Paper page
  20. [23]Adams MC Turkington TG Wilson JM Wong TZ A systematic review of the factors affecting accuracy of SUV measurements AJR Am J Roentgenol 2010 195 310 320 10.2214/AJR.10.4923 20651185 · DOI · Paper page
  21. [24]Tong S Alessio AM Kinahan PE Image reconstruction for PET/CT scanners: past achievements and future challenges Imaging Med 2010 2 529 545 10.2217/iim.10.49 21339831 PMC3039307 · DOI
  22. [25]Teoh EJ McGowan DR Bradley KM Belcher E Black E Gleeson FV Novel penalised likelihood reconstruction of PET in the assessment of histologically verified small pulmonary nodules Eur Radiol 2016 26 576 584 10.1007/s00330-015-3832-y 25991490 PMC4551414 · DOI · Paper page

Cited by

Sorted by citations

Authors
Messerli, M., Stolzmann, P., Egger-Sigg, M., Trinckauf, J., D’Aguanno, S., Burger, I. A., von Schulthess, G. K., Kaufmann, P. A., & Huellner, M. W.
Affiliations
University of Zurich (CH)
Corresponding author
Messerli, Michael
Venue
EJNMMI Physics
Published
2018-09-26
Volume
5
Issue
1
Pages
27-27
ISSN
2197-7364 (ISSN-L)
OpenAlex
W2888114287
Cited by
73
References
1
Citations by year
2026: 6 · 2025: 3 · 2024: 7 · 2023: 11 · 2022: 10 · 2021: 14 · 2020: 10 · 2019: 10 · 2018: 1 · 2012: 1
FWCI
6.05
Type
journal article
Language
en
Open access
Locations
  • EJNMMI Physics (publishedVersion, cc-by)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by)
  • PubMed Central (publishedVersion, cc-by)
  • PubMed (publishedVersion)
  • Zurich Open Repository and Archive (University of Zurich) (acceptedVersion, cc-by)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
  • Zurich Open Repository and Archive (University of Zurich) (submittedVersion, cc-by)
  • Zurich Open Repository and Archive (University of Zurich)
Funders
GE Healthcare (Institutional grants from GE Healthcare (unrelated to current study))
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Medical Imaging Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Lung Cancer Diagnosis and Treatment
Keywords
Bayesian penalized likelihood reconstruction, BSREM, OSEM, lung cancer staging, 18F-FDG PET, PET image quality, SUVmax, signal-to-background ratio, signal-to-noise ratio, time-of-flight PET

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review