Reliability and concurrent validity of knee angle measurement: Smart phone app versus universal goniometer used by experienced and novice clinicians
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
The use of goniometers to measure joint angles is a key part of musculoskeletal practice. Recently smartphone goniometry applications have become available to clinicians. This study examined the intra- and inter-measurer reliability of novice and experienced clinicians and the concurrent validity of assessing knee range of motion using a smartphone application (the Knee Goniometer App (Ockendon(©))) (KGA) and a standard universal goniometer (UG). Three clinicians, each with over seven years' experience as musculoskeletal physiotherapists and three final year physiotherapy students, measured 18 different knee joint angles three times, using both the universal goniometer and the smartphone goniometric application. The universal goniometer and the smartphone goniometric application were reliable in repeated measures of knee flexion angles (average Concordance Correlation Coefficient (CCC) > 0.98) with both experienced clinicians and final year physiotherapy students (average CCCs > 0.96). There were no significant differences in reliability between the experienced and the novice practitioners for either device. Agreement between the universal goniometer and smartphone goniometric application measurements was also high for all examiners with average CCCs all above 0.96. The Standard Error of Measurement ranged between 1.56° (0.52-2.66) for the UG and 0.62° (0.29-1.27) for the KGA. The universal goniometer and the smartphone goniometric application were reliable in repeated measures of knee flexion angles. Smaller error of measurement values for the smartphone goniometric application might indicate superiority for assessment where clinical situations demand greater precision of knee range of motion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785
Cited by
Monitoring Methods of Human Body Joints: State-of-the-Art and Research Challenges
Faisal, A. I., Majumder, S., Mondal, T., Cowan, D., Naseh, S., & Deen, M. J. (2019) · Sensors · doi:10.3390/s19112629 · Cited by 187
Soylu, C., Acar, G., Uzumcu, B., Demir, P., Seyhan, S., & Biyikli, T. (2025) · Life · doi:10.3390/life15010080 · Cited by 7
Metadata
- Authors
- Milanese, S., Gordon, S., Buettner, P., Flavell, C., Ruston, S., Coe, D., O'Sullivan, W., & McCormack, S.
- Venue
- Manual Therapy
- Publisher
- Elsevier BV
- Published
- 2014-12
- Volume
- 19
- Issue
- 6
- Pages
- 569-574
- ISSN
- 1356-689X (ISSN-L)
- OpenAlex
- W2080299022
- Cited by
- 194
- References
- 2
- FWCI
- 11.53
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reliability and concurrent validity of knee angle measurement: Smart phone app versus universal goniometer used by experienced and novice clinicians. https://app.cochat.ai/papers/10.1016/j.math.2014.05.009
- The paper
- Milanese, S., Gordon, S., Buettner, P., Flavell, C., Ruston, S., Coe, D., O'Sullivan, W., & McCormack, S. (2014). Reliability and concurrent validity of knee angle measurement: Smart phone app versus universal goniometer used by experienced and novice clinicians. Manual Therapy. https://doi.org/10.1016/j.math.2014.05.009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.