Monitoring Methods of Human Body Joints: State-of-the-Art and Research Challenges
Open accessThe DOI matches its Crossref record; 146 of the 150 references it cites were found in a registry or an index.
Abstract
The world’s population is aging: the expansion of the older adult population with multiple physical and health issues is now a huge socio-economic concern worldwide. Among these issues, the loss of mobility among older adults due to musculoskeletal disorders is especially serious as it has severe social, mental and physical consequences. Human body joint monitoring and early diagnosis of these disorders will be a strong and effective solution to this problem. A smart joint monitoring system can identify and record important musculoskeletal-related parameters. Such devices can be utilized for continuous monitoring of joint movements during the normal daily activities of older adults and the healing process of joints (hips, knees or ankles) during the post-surgery period. A viable monitoring system can be developed by combining miniaturized, durable, low-cost and compact sensors with the advanced communication technologies and data processing techniques. In this study, we have presented and compared different joint monitoring methods and sensing technologies recently reported. A discussion on sensors’ data processing, interpretation, and analysis techniques is also presented. Finally, current research focus, as well as future prospects and development challenges in joint monitoring systems are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures














Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Murray, C. J. L., Vos, T., Lozano, R., Naghavi, M., Flaxman, A. D., Michaud, C., Ezzati, M., Shibuya, K., Salomon, J. A., Abdalla, S., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)61689-4 · Cited by 8,888
Wearable Sensors for Human Activity Monitoring: A Review
Mukhopadhyay, S. C. (2015) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2370945 · Cited by 1,401
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
Self-citationComputational Methods of Feature Selection
(2007) · Chapman & Hall/CRC eBooks · doi:10.1201/9781584888796 · Cited by 1,271
Muro-de-la-Herran, A., Garcia-Zapirain, B., & Mendez-Zorrilla, A. (2014) · Sensors · doi:10.3390/s140203362 · Cited by 1,172
A survey on ambient-assisted living tools for older adults
Rashidi, P., & Mihailidis, A. (2013) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2012.2234129 · Cited by 1,128
An Introduction to Machine Learning
Kubat, M. (2015) · Springer eBooks · doi:10.1007/978-3-319-20010-1 · Cited by 1,007
Feature Selection via Concave Minimization and Support Vector Machines
Bradley, P. S., & Mangasarian, O. L. (1998) · Cited by 984
IMU-Based Joint Angle Measurement for Gait Analysis
Seel, T., Raisch, J., & Schauer, T. (2014) · Sensors · doi:10.3390/s140406891 · Cited by 867
Extremely Elastic Wearable Carbon Nanotube Fiber Strain Sensor for Monitoring of Human Motion
Ryu, S., Lee, P., Chou, J. B., Xu, R., Zhao, R., Hart, A. J., & Kim, S.-G. (2015) · ACS Nano · doi:10.1021/acsnano.5b00599 · Cited by 770
Research works printed but not linked: 6
- OpenStax (2019, June 06). Anatomy and Physiology: Chapter 9.4 Synovial Joints. Available online: http://cnx.org/contents/14fb4ad7-39a1-4eee-ab6e-3ef2482e3e22@8.24.
- Seel, T., and Schauer, T. (2013, January 14–15). IMU-based joint angle measurement made practical. Proceedings of the 4th European Conference on Technically Assisted Rehabilitation, Berlin, Germany. · DOI · Paper page
- Bergmann, T., and Peterson, D. (2010). Chiropractic Technique: Chapter 2 Joint Anatomy and Basic Biomechanics. Chiropractic Technique, Elsevier/Mosby.
- Slightam, J.E. (2016). Modeling and Simulation of Biologically Inspired 3D-Printed Fluid Power Robotic System Architectures. [Ph.D. Thesis, Milwaukee School of Engineering].
- Rakheja, 2012, Knee Deformity Recognition and Deform Angle Measurement, Int. J. Appl. Inf. Syst., 3, 47
- Yousefpour, 2014, A comparative study on sentiment analysis, Adv. Environ. Biol., 8, 53
Cited by
Sharma, S., Chhetry, A., Sharifuzzaman, M., Yoon, H., & Park, J. Y. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c05819 · Cited by 454
Advances in triboelectric nanogenerators for biomedical sensing
Tat, T., Libanori, A., Au, C., Yau, A., & Chen, J. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112714 · Cited by 243
Technologies Trend towards 5G Network for Smart Health-Care Using IoT: A Review
Ahad, A., Tahir, M., Aman Sheikh, M., Ahmed, K. I., Mughees, A., & Numani, A. (2020) · Sensors · doi:10.3390/s20144047 · Cited by 240
Wearable Sensors for Monitoring Human Motion: A Review on Mechanisms, Materials, and Challenges
Homayounfar, S. Z., & Andrew, T. L. (2020) · SLAS TECHNOLOGY · doi:10.1177/2472630319891128 · Cited by 227
“Kuang et al.(11) have proposed an extrinsic-type sensor of POF for strain measurements, which is composed of two fibers placed in line with each other, one attached to the light source and the other to the photodetector.”
BackgroundWearable Sensor Systems for Fall Risk Assessment: A Review
Subramaniam, S., Faisal, A. I., & Deen, M. J. (2022) · Frontiers in Digital Health · doi:10.3389/fdgth.2022.921506 · Cited by 175
Self-citation
Metadata
- Authors
- Faisal, A. I., Majumder, S., Mondal, T., Cowan, D., Naseh, S., & Deen, M. J.
- Affiliations
- McMaster University (CA)
- St. Joseph’s Healthcare Hamilton (CA)
- Corresponding author
- Deen, M. Jamal
- Venue
- Sensors
- Publisher
- MDPI AG
- Published
- 2019-06-10
- Volume
- 19
- Issue
- 11
- Pages
- 2629
- ISSN
- 1424-8220 (ISSN-L)
- PMC
- PMC6603670
- OpenAlex
- W2948471521
- Cited by
- 187
- References
- 150
- Citations by year
- 2026: 14 · 2025: 27 · 2024: 41 · 2023: 28 · 2022: 24 · 2021: 25 · 2020: 25 · 2019: 3
- FWCI
- 2.04
- Type
- journal article
- Language
- en
- Open access
- gold
- dx.doi.org
- Licence
- Locations
- Sensors (publishedVersion, cc-by)
- Europe PMC (PubMed Central) (publishedVersion, cc-by)
- PubMed Central (publishedVersion, cc-by)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Canada Research Chairs (xx)
- Topics
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Keywords
- joint monitoring, musculoskeletal disorders, older adults, mobility loss, wearable sensors, intelligent monitoring system, sensor data processing, early diagnosis, postoperative rehabilitation, population aging
- MeSH terms
- Wearable Electronic Devices, Aged, Biomechanical Phenomena, Female, Humans, Joints, Monitoring, Physiologic, Movement, Range of Motion, Articular, Human Body
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Monitoring Methods of Human Body Joints: State-of-the-Art and Research Challenges. https://app.cochat.ai/papers/10.3390/s19112629
- The paper
- Faisal, A. I., Majumder, S., Mondal, T., Cowan, D., Naseh, S., & Deen, M. J. (2019). Monitoring Methods of Human Body Joints: State-of-the-Art and Research Challenges. Sensors. https://doi.org/10.3390/s19112629
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.