The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Hierarchically Structured Stretchable Conductive Hydrogels for High-Performance Wearable Strain Sensors and Supercapacitors
Open accessAbstract
Summary Stretchable conductive materials, a critical building block of soft electronics, typically require multiple components that synergistically contribute good mechanical, electrical, and interfacial properties. The overall performance is often hindered by phase instability and poor miscibility of functional fillers within polymer matrices, compromising the conductive percolative network. We addressed this challenge with an ice-templated, low-temperature polymerization (ITLP) strategy and created stretchable conducting hydrogels. Owning a hierarchical dendritic microstructure with mitigated nanoaggregation, the material exhibited 29-fold enhancement in toughness and 83-fold increase in conductivity. Strain sensors using such gels demonstrated a broad detection range, high sensitivity, and health-monitoring capability. ITLP gel electrodes exhibited 888 F/g specific capacitance and 2,097 mF/cm2 areal capacitance (368 F/g) when used in solid-state supercapacitors. Flexible and stretchable wearable supercapacitors have been successfully made and can power LEDs. The ITLP strategy is anticipated to create diverse high-performance soft-electronic materials for broad applications in energy, healthcare, and robotics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Yang, J. C., Mun, J., Kwon, S. Y., Park, S., Bao, Z., & Park, S. (2019) · Advanced Materials · doi:10.1002/adma.201904765 · Cited by 1,641
Hierarchical nanostructured conducting polymer hydrogel with high electrochemical activity
Pan, L., Yu, G., Zhai, D., Lee, H. R., Zhao, W., Liu, N., Wang, H., Tee, B. C.-K., Shi, Y., Cui, Y., et al. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1202636109 · Cited by 1,216
Cited by
End-to-end design of wearable sensors
Ates, H. C., Nguyen, P. Q., Gonzalez-Macia, L., Morales-Narváez, E., Güder, F., Collins, J. J., & Dincer, C. (2022) · Nature Reviews Materials · doi:10.1038/s41578-022-00460-x · Cited by 1,306
3D printable high-performance conducting polymer hydrogel for all-hydrogel bioelectronic interfaces
Zhou, T., Yuk, H., Hu, F., Wu, J., Tian, F., Roh, H., Shen, Z., Gu, G., Xu, J., Lu, B., et al. (2023) · Nature Materials · doi:10.1038/s41563-023-01569-2 · Cited by 587
Multifunctional conductive hydrogel-based flexible wearable sensors
Wang, L., Xu, T., & Zhang, X. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116130 · Cited by 507
Solution-processable, soft, self-adhesive, and conductive polymer composites for soft electronics
Tan, P., Wang, H., Xiao, F., Lu, X., Shang, W., Deng, X., Song, H., Xu, Z., Cao, J., Gan, T., et al. (2022) · Nature Communications · doi:10.1038/s41467-022-28027-y · Cited by 403
Somatosensory actuator based on stretchable conductive photothermally responsive hydrogel
Zhao, Y., Lo, C.-Y., Ruan, L., Pi, C.-H., Kim, C., Alsaid, Y., Frenkel, I., Rico, R., Tsao, T.-C., & He, X. (2021) · Science Robotics · doi:10.1126/scirobotics.abd5483 · Cited by 317
Self-citation
Metadata
- Authors
- Zhao, Y., Zhang, B., Yao, B., Qiu, Y., Peng, Z., Zhang, Y., Alsaid, Y., Frenkel, I., Youssef, K., Pei, Q., & He, X.
- Venue
- Matter
- Publisher
- Elsevier BV
- Published
- 2020-10
- Volume
- 3
- Issue
- 4
- Pages
- 1196-1210
- ISSN
- 2590-2385 (ISSN-L)
- OpenAlex
- W3087266752
- Cited by
- 219
- References
- 2
- FWCI
- 8.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hierarchically Structured Stretchable Conductive Hydrogels for High-Performance Wearable Strain Sensors and Supercapacitors. https://app.cochat.ai/papers/10.1016/j.matt.2020.08.024
- The paper
- Zhao, Y., Zhang, B., Yao, B., Qiu, Y., Peng, Z., Zhang, Y., Alsaid, Y., Frenkel, I., Youssef, K., Pei, Q., & He, X. (2020). Hierarchically Structured Stretchable Conductive Hydrogels for High-Performance Wearable Strain Sensors and Supercapacitors. Matter. https://doi.org/10.1016/j.matt.2020.08.024
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.