The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Graphene–protein field effect biosensors: glucose sensing
Open accessAbstract
Chronic diseases are becoming more prevalent, and the complexities of managing patients continue to escalate, since their care must be balanced between the home and clinical settings. Diabetes is the most advanced example, where self-monitoring has been shown to be necessary. Glucometers are point-of-care (POC) devices that have become standard platforms at home and clinical settings. Similarly, many other POC biosensors have also been developed. Enzymes are often used in these sensors because of their specificity and the reaction products can be electrochemically transduced for the measurement. When enzymes are immobilized to an electronically active substrate, enzymatic reactions can be transduced by direct electron transport. This paper describes an approach for the development of graphene-based POC devices. This includes modifying enzymes for improved performance, developing methods to bind them to the graphene surface, incorporation of the functionalized graphene on a field-effect transistor (FET), and integration into a microfluidic device suitable for home use. This paper describes an approach for the development of a graphene-based POC biosensor platform using glucose as an example of target molecule.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrochemical Glucose Biosensors
Wang, J. (2008) · Chemical Reviews · doi:10.1021/cr068123a · Cited by 3,498
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137
Graphene nanoelectronic heterodyne sensor for rapid and sensitive vapour detection
Kulkarni, G. S., Reddy, K., Zhong, Z., & Fan, X. (2014) · Nature Communications · doi:10.1038/ncomms5376 · Cited by 189
Klonoff, D. C., & Reyes, J. S. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700432 · Cited by 29
Cited by
Mechanisms of the Antimicrobial Activities of Graphene Materials
Zou, X., Zhang, L., Wang, Z., & Luo, Y. (2016) · Journal of the American Chemical Society · doi:10.1021/jacs.5b11411 · Cited by 934
Cheng, C., Li, S., Thomas, A., Kotov, N. A., & Haag, R. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00520 · Cited by 527
Xu, S., Zhan, J., Man, B., Jiang, S., Yue, W., Gao, S., Guo, C., Liu, H., Li, Z., Wang, J., et al. (2017) · Nature Communications · doi:10.1038/ncomms14902 · Cited by 437
Flexible Electronics: Status, Challenges and Opportunities
Corzo, D., Tostado-Blázquez, G., & Baran, D. (2020) · Frontiers in Electronics · doi:10.3389/felec.2020.594003 · Cited by 391
Sensing at the Surface of Graphene Field‐Effect Transistors
Fu, W., Jiang, L., van Geest, E. P., Lima, L. M. C., & Schneider, G. F. (2017) · Advanced Materials · doi:10.1002/adma.201603610 · Cited by 364
Metadata
- Authors
- Viswanathan, S., Narayanan, T. N., Aran, K., Fink, K. D., Paredes, J., Ajayan, P. M., Filipek, S., Miszta, P., Tekin, H. C., Inci, F., Demirci, U., Li, P., Bolotin, K. I., Liepmann, D., & Renugopalakrishanan, V.
- Venue
- Materials Today
- Publisher
- Elsevier BV
- Published
- 2015-11
- Volume
- 18
- Issue
- 9
- Pages
- 513-522
- ISSN
- 1369-7021 (ISSN-L)
- OpenAlex
- W2067682084
- Cited by
- 162
- References
- 4
- FWCI
- 8.50
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Graphene–protein field effect biosensors: glucose sensing. https://app.cochat.ai/papers/10.1016/j.mattod.2015.04.003
- The paper
- Viswanathan, S., Narayanan, T. N., Aran, K., Fink, K. D., Paredes, J., Ajayan, P. M., Filipek, S., Miszta, P., Tekin, H. C., Inci, F., Demirci, U., Li, P., Bolotin, K. I., Liepmann, D., & Renugopalakrishanan, V. (2015). Graphene–protein field effect biosensors: glucose sensing. Materials Today. https://doi.org/10.1016/j.mattod.2015.04.003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.