The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Factors influencing Recombinase polymerase amplification (RPA) assay outcomes at point of care
Open accessAbstract
Recombinase Polymerase Amplification (RPA) can be used to detect pathogen-specific DNA or RNA in under 20 minutes without the need for complex instrumentation. These properties enable its potential use in resource limited settings. However, there are concerns that deviations from the manufacturer’s protocol and/or storage conditions could influence its performance in low resource settings. RPA amplification relies upon viscous crowding agents for optimal nucleic acid amplification, and thus an interval mixing step after 3–6 minutes of incubation is recommended to distribute amplicons and improve performance. In this study we used a HIV-1 RPA assay to evaluate the effects of this mixing step on assay performance. A lack of mixing led to a longer time to amplification and inferior detection signal, compromising the sensitivity of the assay. However lowering the assay volume from 50 μL to 5 μL showed similar sensitivity with or without mixing. We present the first peer-reviewed study that assesses long term stability of RPA reagents without a cold chain. Reagents stored at −20°C, and 25°C for up to 12 weeks were able to detect 10 HIV-1 DNA copies. Reagents stored at 45°C for up to 3 weeks were able to detect 10 HIV-1 DNA copies, with reduced sensitivity only after >3 weeks at 45°C. Together our results show that reducing reaction volumes bypassed the need for the mixing step and that RPA reagents were stable even when stored for 3 weeks at very high temperatures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
NIH Image to ImageJ: 25 years of image analysis
Schneider, C. A., Rasband, W. S., & Eliceiri, K. W. (2012) · Nature Methods · doi:10.1038/nmeth.2089 · Cited by 64,638
Macromolecular crowding: obvious but underappreciated
Ellis, R. J. (2001) · Trends in Biochemical Sciences · doi:10.1016/s0968-0004(01)01938-7 · Cited by 2,309
Cross-Priming Amplification for Rapid Detection of Mycobacterium tuberculosis in Sputum Specimens
Fang, R., Li, X., Hu, L., You, Q., Li, J., Wu, J., Xu, P., Zhong, H., Luo, Y., Mei, J., et al. (2009) · Journal of Clinical Microbiology · doi:10.1128/jcm.01528-08 · Cited by 167
Cited by
Kaminski, M. M., Abudayyeh, O. O., Gootenberg, J. S., Zhang, F., & Collins, J. J. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00760-7 · Cited by 1,259
Recombinase polymerase amplification: Basics, applications and recent advances
Lobato, I. M., & O'Sullivan, C. K. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.10.015 · Cited by 1,146
Review: a comprehensive summary of a decade development of the recombinase polymerase amplification
Li, J., Macdonald, J., & von Stetten, F. (2019) · The Analyst · doi:10.1039/c8an01621f · Cited by 648
Reid, M. S., Le, X. C., & Zhang, H. (2018) · Angewandte Chemie International Edition · doi:10.1002/anie.201712217 · Cited by 338
Rapid and Fully Microfluidic Ebola Virus Detection with CRISPR-Cas13a
Qin, P., Park, M., Alfson, K. J., Tamhankar, M., Carrion, R., Patterson, J. L., Griffiths, A., He, Q., Yildiz, A., Mathies, R., et al. (2019) · ACS Sensors · doi:10.1021/acssensors.9b00239 · Cited by 311
Metadata
- Authors
- Lillis, L., Siverson, J., Lee, A., Cantera, J., Parker, M., Piepenburg, O., Lehman, D. A., & Boyle, D. S.
- Venue
- Molecular and Cellular Probes
- Publisher
- Elsevier BV
- Published
- 2016-04
- Volume
- 30
- Issue
- 2
- Pages
- 74-78
- ISSN
- 0890-8508 (ISSN-L)
- OpenAlex
- W2257499382
- Cited by
- 206
- References
- 3
- FWCI
- 8.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Factors influencing Recombinase polymerase amplification (RPA) assay outcomes at point of care. https://app.cochat.ai/papers/10.1016/j.mcp.2016.01.009
- The paper
- Lillis, L., Siverson, J., Lee, A., Cantera, J., Parker, M., Piepenburg, O., Lehman, D. A., & Boyle, D. S. (2016). Factors influencing Recombinase polymerase amplification (RPA) assay outcomes at point of care. Molecular and Cellular Probes. https://doi.org/10.1016/j.mcp.2016.01.009
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.