Cited by 167Tuberculosis Research and EpidemiologyBiosensors and Analytical DetectionMycobacterium research and diagnosis

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Cross-Priming Amplification for Rapid Detection of Mycobacterium tuberculosis in Sputum Specimens

Open access
Fang, Rendong, Li, Xia, Hu, Lin, You, Qimin, Li, Jing, Wu, Jie, Xu, Peng, Zhong, Huayan, Luo, Ying, Mei, Jian, Gao, Qian·2009·Journal of Clinical Microbiology

Abstract

Cross-priming amplification (CPA) technology for tuberculosis diagnosis from sputum specimens was evaluated. The sensitivity of CPA from smear- and liquid culture-positive specimens was 96.9%, and that from smear-negative and liquid culture-positive specimens was 87.5%. The specificity of CPA in culture-negative specimens was 98.8%.

Overview

Integrity signals

Registry

Crossref · 10.1128/jcm.01528-08

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Flagged first, then by citations

Research works printed but not linked: 1

  1. Kong, H., T. Ranalli, and B. Lemieux. 2007. New isothermal molecular diagnostics platforms. IVD Technol. 13:35-43.

Cited by

Sorted by citations

Metadata

Authors
Fang, R., Li, X., Hu, L., You, Q., Li, J., Wu, J., Xu, P., Zhong, H., Luo, Y., Mei, J., & Gao, Q.
Affiliations
  • Shanghai Medical College of Fudan University (CN)
  • Ustar Biotechnologies (China) (CN)
  • Shanghai Municipal Center For Disease Control Prevention (CN)
Venue
Journal of Clinical Microbiology
Published
2009-03
Volume
47
Issue
3
Pages
845-847
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2167026482
Cited by
167
References
10
Citations by year
2026: 7 · 2025: 10 · 2024: 17 · 2023: 11 · 2022: 9 · 2021: 11 · 2020: 11 · 2019: 9 · 2018: 9 · 2017: 9 · 2016: 13 · 2015: 17 · 2014: 12 · 2013: 7 · 2012: 8
FWCI
1.51
Type
journal article
Language
en
Open access
Locations
  • Journal of Clinical Microbiology (publishedVersion)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
Fogarty International Center (D43TW007887)
Topics
  • Health Sciences › Medicine › Infectious Diseases › Tuberculosis Research and Epidemiology
  • Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
  • Health Sciences › Medicine › Epidemiology › Mycobacterium research and diagnosis
Keywords
cross-priming amplification, Mycobacterium tuberculosis, tuberculosis diagnosis, sputum samples, nucleic acid amplification, smear-negative tuberculosis, liquid culture, sensitivity and specificity
MeSH terms
Base Sequence, Humans, Molecular Sequence Data, Mycobacterium tuberculosis, Sensitivity and Specificity, Sputum, Tuberculosis, DNA Primers, Nucleic Acid Amplification Techniques

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review