Abstract

In stark contrast to the inspiring functionality of the natural hand, limitations of current upper limb prostheses stemming from marginal feedback control, challenges of mechanical design, and lack of sensory capacity, are well-established. This paper provides a critical review of current sensory systems and the potential of a selection of electroactive polymers for sensory applications in hand prostheses. Candidate electroactive polymers are reviewed in terms of their relevant advantages and disadvantages, together with their current implementation in related applications. Empirical analysis of one of the most novel electroactive polymers, ionic polymer metal composites (IPMC), was conducted to demonstrate its potential for prosthetic applications. With linear responses within the operating range typical of hand prostheses, bending angles, and bending rates were accurately measured with 4.4+/-2.5 and 4.8+/-3.5% error, respectively, using the IPMC sensors. With these comparable error rates to traditional resistive bend sensors and a wide range of sensitivities and responses, electroactive polymers offer a promising alternative to more traditional sensory approaches. Their potential role in prosthetics is further heightened by their flexible and formable structure, and their ability to act as both sensors and actuators.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.medengphy.2005.09.009

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 154

Metadata

Authors
Biddiss, E., & Chau, T.
Venue
Medical Engineering & Physics
Published
2005-11-02
Volume
28
Issue
6
Pages
568-578
ISSN
  • 1350-4533 (ISSN-L)
  • 1873-4030
OpenAlex
W1985952684
Cited by
154
References
3
FWCI
1.20
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Electroactive polymeric sensors in hand prostheses: Bending response of an ionic polymer metal composite. https://app.cochat.ai/papers/10.1016/j.medengphy.2005.09.009
The paper
Biddiss, E., & Chau, T. (2006). Electroactive polymeric sensors in hand prostheses: Bending response of an ionic polymer metal composite. Medical Engineering & Physics. https://doi.org/10.1016/j.medengphy.2005.09.009

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.