Cited by 90Elasticity and Material ModelingAdvanced Materials and MechanicsSkin Protection and Aging

Mechanical approach to aging and wrinkling of human facial skin based on the multistage buckling theory

Open access
Kuwazuru, Osamu, Saothong, Jariyaporn, Yoshikawa, Nobuhiro·2008·Medical Engineering & Physics

Abstract

A wrinkle formation mechanism with cutaneous aging is addressed through a mechanical calculation of linear buckling. Skin is divided into five mechanically distinct layers in this study. In general, the outer layer is stiffer than the inner layer, so buckling occurs in the outer layer against the uniform compression caused by muscle contraction. This buckling damages the skin and affects the formation of permanent wrinkles. We propose a multistage buckling theory for evaluation of the wrinkle property, namely, the specific wrinkle size and critical strain in three stages. The specific wrinkle size is derived as the wavelength of the minimum-buckling mode for infinite-length skin. A sensitivity analysis is carried out to investigate the effect of age-related changes of the mechanical parameters on the wrinkle property. We employ some aging hypotheses and prepare two sets of mechanical parameters, one for young and one for aged skin. The numerical results show that the buckling mode switch from Stage I to Stage II is the main reason why pronounced wrinkles suddenly appear in aged skin.

Integrity signals

Registry

Crossref · 10.1016/j.medengphy.2007.06.001

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The device had a resolution of 1.3% in strain detection.

    “The device had a resolution of 1.3% in strain detection.”

    From Wearables in Medicine (2018) · cites this paper as [17]

  • This sensor may allow monitoring the mechanical properties of the skin (e.g., lymphedema).

    “This sensor may allow monitoring the mechanical properties of the skin (e.g., lymphedema).17”

    From Wearables in Medicine (2018) · cites this paper as [17]

  • Conformal epidermal sensors were designed for strain detection.

    “In another study, conformal epidermal sensors were designed for strain detection.17”

    From Wearables in Medicine (2018) · cites this paper as [17]

Cited by

Sorted by citations

Authors
Kuwazuru, O., Saothong, J., & Yoshikawa, N.
Affiliations
Institute of Industrial Science, The University of Tokyo (JP)
Corresponding author
Kuwazuru, Osamu
Venue
Medical Engineering & Physics
Published
2007-07-27
Volume
30
Issue
4
Pages
516-522
ISSN
  • 1350-4533 (ISSN-L)
  • 1873-4030
OpenAlex
W1989273716
Cited by
90
References
0
Citations by year
2026: 3 · 2025: 10 · 2024: 3 · 2023: 3 · 2022: 4 · 2021: 4 · 2020: 5 · 2019: 3 · 2018: 7 · 2017: 3 · 2016: 5 · 2015: 5 · 2014: 7 · 2013: 7 · 2012: 9
FWCI
1.67
Type
journal article
Language
en
Open access
Locations
  • Medical Engineering & Physics (publishedVersion)
  • PubMed (publishedVersion)
  • University of Fukui Library (University of Fukui) (submittedVersion)
  • Fukui University Repository (University of Fukui) (submittedVersion, cc-by-nc-nd)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
  • Physical Sciences › Engineering › Mechanical Engineering › Advanced Materials and Mechanics
  • Health Sciences › Medicine › Dermatology › Skin Protection and Aging
Keywords
skin aging, facial wrinkles, linear buckling, muscle contraction, critical strain, wrinkle wavelength, sensitivity analysis
MeSH terms
Adult, Aged, Aging, Biomedical Engineering, Epidermis, Equipment Design, Humans, Middle Aged, Skin, Skin Physiological Phenomena, Stress, Mechanical, Models, Statistical, Skin Aging, Dermis, Subcutaneous Tissue

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review