CoChat

Effect of tissue mechanical properties on cuff-based blood pressure measurements

Lan, H., Al-Jumaily, A.M., Lowe, A., Hing, W. · 2011 · Medical Engineering & Physics
Cited by 47

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

This paper presents a 3D finite element upper arm model, validated by experiments as well as clinical data, used to study the error introduced in blood pressure measurements due to variability of arm tissue mechanical properties. The model consists of three separate cylindrical parts: soft tissue, bone and brachial artery. The artery volume changes under the cuff are used to represent the cuff pressure oscillations for analyzing blood pressure measurements. These oscillation trends are identical to observed clinical data. Also an upper arm simulator is designed and built for model validation. The model shows that the variation of soft tissue compressibility introduces an error up to 5% in blood pressure measurements. It is also revealed that the variation of the brachial artery and arm tissue stiffness has an insignificant effect on oscillometric blood pressure measurement method.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.medengphy.2011.06.006

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Lan, H., Al-Jumaily, A. M., Lowe, A., & Hing, W.
Venue
Medical Engineering & Physics
Published
2011-07-12
Volume
33
Issue
10
Pages
1287-1292
ISSN
  • 1350-4533 (ISSN-L)
  • 1873-4030
OpenAlex
W1985749266
Cited by
47
References
5
FWCI
2.01
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.