Effect of tissue mechanical properties on cuff-based blood pressure measurements
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
This paper presents a 3D finite element upper arm model, validated by experiments as well as clinical data, used to study the error introduced in blood pressure measurements due to variability of arm tissue mechanical properties. The model consists of three separate cylindrical parts: soft tissue, bone and brachial artery. The artery volume changes under the cuff are used to represent the cuff pressure oscillations for analyzing blood pressure measurements. These oscillation trends are identical to observed clinical data. Also an upper arm simulator is designed and built for model validation. The model shows that the variation of soft tissue compressibility introduces an error up to 5% in blood pressure measurements. It is also revealed that the variation of the brachial artery and arm tissue stiffness has an insignificant effect on oscillometric blood pressure measurement method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Circulation · doi:10.1161/01.cir.0000154900.76284.f6 · Cited by 3,985
Pickering, T. G., Hall, J. E., Appel, L. J., Falkner, B. E., Graves, J., Hill, M. N., Jones, D. W., Kurtz, T., Sheps, S. G., & Roccella, E. J. (2005) · Hypertension · doi:10.1161/01.hyp.0000150859.47929.8e · Cited by 2,051
Martin, R. B., Burr, D. B., Sharkey, N. A., & Fyhrie, D. P. (2015) · doi:10.1007/978-1-4939-3002-9 · Cited by 1,159
Characterization of the oscillometric method for measuring indirect blood pressure
Geddes, L. A., Voelz, M., Combs, C., Reiner, D., & Babbs, C. F. (1982) · Annals of Biomedical Engineering · doi:10.1007/bf02367308 · Cited by 340
Ursino, M., & Cristalli, C. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.508540 · Cited by 179
Cited by
Oscillometric Blood Pressure Estimation: Past, Present, and Future
Forouzanfar, M., Dajani, H. R., Groza, V. Z., Bolic, M., Rajan, S., & Batkin, I. (2015) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2015.2434215 · Cited by 196
Cuff challenges in blood pressure measurement
Palatini, P., & Asmar, R. (2018) · The Journal of Clinical Hypertension · doi:10.1111/jch.13301 · Cited by 60
Palatini, P., Benetti, E., Fania, C., & Saladini, F. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000001823 · Cited by 42
Effect of the shape of the cuff on blood pressure measurement in people with large arms
Palatini, P., Benetti, E., Fania, C., Ermolao, A., Spinella, P., Battista, F., Gasperetti, A., & Saladini, F. (2020) · Blood Pressure · doi:10.1080/08037051.2020.1738913 · Cited by 16
Cuff Design for Home Blood Pressure Monitors
Palatini, P., Asmar, R., Bilo, G., & Parati, G. (2020) · Updates in Hypertension and Cardiovascular Protection · doi:10.1007/978-3-030-23065-4_2 · Cited by 2
Metadata
- Authors
- Lan, H., Al-Jumaily, A. M., Lowe, A., & Hing, W.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2011-07-12
- Volume
- 33
- Issue
- 10
- Pages
- 1287-1292
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W1985749266
- Cited by
- 47
- References
- 5
- FWCI
- 2.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.