Cited by 185Balance, Gait, and Falls PreventionLower Extremity Biomechanics and PathologiesTotal Knee Arthroplasty Outcomes

Validity of the Optogait photoelectric system for the assessment of spatiotemporal gait parameters

Lienhard, Karin, Schneider, David, Maffiuletti, Nicola A.·2013·Medical Engineering & Physics

Abstract

The purpose of this study was to evaluate the discriminant and concurrent (criterion-related) validity of a recently introduced floor-based photocell system (Optogait, Microgate, Bolzano, Italy) with a validated electronic walkway for the assessment of spatiotemporal gait parameters. Fifteen patients (mean age±standard deviation: 65±7 years) with total knee arthroplasty and 15 healthy matched control subjects were asked to walk at different velocities while gait variables were recorded simultaneously by the two instruments. The Optogait and the criterion instrument detected the same differences in walking parameters between patients and controls. Intraclass correlation coefficients ranged between 0.933 (swing time) and 0.999 (cycle time, cadence and walking speed). Cycle time and stance time were significantly longer, while swing time, step length, cadence and walking speed were significantly lower for Optogait (p<0.001) compared to the criterion instrument. The Optogait system demonstrated high discriminant and concurrent validity with an electronic walkway for the assessment of spatiotemporal gait parameters in orthopedic patients and healthy controls. However, the two measuring instruments cannot be used interchangeably for quantitative gait analysis, and further validation of floor-based photocell technology is warranted.

Integrity signals

Registry

Crossref · 10.1016/j.medengphy.2012.06.015

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Lienhard, K., Schneider, D., & Maffiuletti, N. A.
Affiliations
Schulthess-Klinik (CH)
Corresponding author
Maffiuletti, Nicola A.
Venue
Medical Engineering & Physics
Published
2012-07-18
Volume
35
Issue
4
Pages
500-504
ISSN
  • 1350-4533 (ISSN-L)
  • 1873-4030
OpenAlex
W2117925202
Cited by
185
References
19
Citations by year
2026: 16 · 2025: 20 · 2024: 14 · 2023: 6 · 2022: 18 · 2021: 22 · 2020: 21 · 2019: 19 · 2018: 13 · 2017: 8 · 2016: 12 · 2015: 8 · 2014: 4 · 2013: 4
FWCI
12.62
Type
journal article
Language
en
Open access
closed
Locations
  • Medical Engineering & Physics (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
  • Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
  • Health Sciences › Medicine › Surgery › Total Knee Arthroplasty Outcomes
Keywords
OptoGait, spatiotemporal gait parameters, total knee arthroplasty, assessment validity, discriminant validity, concurrent validity, gait analysis, walking speed, cadence, cycle time, swing time, stance time, step length
MeSH terms
Aged, Female, Gait, Humans, Male, Orthopedics, Electrical Equipment and Supplies, Spatio-Temporal Analysis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review