Validity of the Optogait photoelectric system for the assessment of spatiotemporal gait parameters
Abstract
The purpose of this study was to evaluate the discriminant and concurrent (criterion-related) validity of a recently introduced floor-based photocell system (Optogait, Microgate, Bolzano, Italy) with a validated electronic walkway for the assessment of spatiotemporal gait parameters. Fifteen patients (mean age±standard deviation: 65±7 years) with total knee arthroplasty and 15 healthy matched control subjects were asked to walk at different velocities while gait variables were recorded simultaneously by the two instruments. The Optogait and the criterion instrument detected the same differences in walking parameters between patients and controls. Intraclass correlation coefficients ranged between 0.933 (swing time) and 0.999 (cycle time, cadence and walking speed). Cycle time and stance time were significantly longer, while swing time, step length, cadence and walking speed were significantly lower for Optogait (p<0.001) compared to the criterion instrument. The Optogait system demonstrated high discriminant and concurrent validity with an electronic walkway for the assessment of spatiotemporal gait parameters in orthopedic patients and healthy controls. However, the two measuring instruments cannot be used interchangeably for quantitative gait analysis, and further validation of floor-based photocell technology is warranted.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Face-to-face ACT is considered an effective treatment for children and adolescents with anxiety disorders.
“Face-to-face ACT is considered an effective treatment for children and adolescents with anxiety disorders [14,15]”
Face-to-face ACT exhibits small to medium effect sizes regarding anxiety and depression.
“exhibits small to medium effect sizes regarding anxiety and depression [16].”
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965 · see citing works
Beckett, A. H., Rowland, M., & TURNER, P. (1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,917 · see citing works
Normative spatiotemporal gait parameters in older adults
Hollman, J. H., McDade, E., & Petersen, R. C. (2011) · Gait & Posture · doi:10.1016/j.gaitpost.2011.03.024 · Cited by 814 · see citing works
Bilney, B., Morris, M. E., & Webster, K. E. (2003) · Gait & Posture · doi:10.1016/s0966-6362(02)00053-x · Cited by 738 · see citing works
Validity and Reliability of Optojump Photoelectric Cells for Estimating Vertical Jump Height
Item‐Glatthorn, J. F., Gouge, S., Nussbaumer, S., Stauffacher, S., Impellizzeri, F. M., & Maffiuletti, N. A. (2010) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e3181ccb18d · Cited by 704 · see citing works
Self-citationWebster, K. E., Wittwer, J. E., & Feller, J. A. (2004) · Gait & Posture · doi:10.1016/j.gaitpost.2004.10.005 · Cited by 556 · see citing works
The validity and reliability of the GAITRite system's measurements: A preliminary evaluation
McDonough, A. L., Batavia, M., Chen, F. C., Kwon, S., & Ziai, J. M. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.19778 · Cited by 530 · see citing works
Reliability of Observational Kinematic Gait Analysis
Krebs, D. E., Edelstein, J. E., & Fishman, S. (1985) · Physical Therapy · doi:10.1093/ptj/65.7.1027 · Cited by 303 · see citing works
Test–retest reliability of trunk accelerometric gait analysis
Henriksen, M., Lund, H., Moe‐Nilssen, R., Bliddal, H., & Danneskiold‐Samsøe, B. (2003) · Gait & Posture · doi:10.1016/s0966-6362(03)00069-9 · Cited by 287 · see citing works
Evaluation of an instrumented walkway for measurement of the kinematic parameters of gait
Cutlip, R. G., Mancinelli, C. A., Huber, F. E., & DiPasquale, J. (2000) · Gait & Posture · doi:10.1016/s0966-6362(00)00062-x · Cited by 176 · see citing works
Reliability of techniques to assess human neuromuscular function in vivo
Clark, B. C., Cook, S. B., & Ploutz-Snyder, L. L. (2007) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2005.11.008 · Cited by 107 · see citing works
Maffiuletti, N. A., Gorelick, M., Quervain, I. A. K., Bizzini, M., Petrich-Munzinger, J., Tomasetti, S., & Stacoff, A. (2007) · Gait & Posture · doi:10.1016/j.gaitpost.2007.01.003 · Cited by 94 · see citing works
Self-citationEsser, P., Dawes, H., Collett, J., Feltham, M. G., & Howells, K. (2011) · Gait & Posture · doi:10.1016/j.gaitpost.2011.06.018 · Cited by 89 · see citing works
Spatiotemporal Parameters of Gait After Total Hip Replacement: Anterior versus Posterior Approach
Maffiuletti, N. A., Impellizzeri, F. M., Widler, K., et al. (2009) · Orthopedic Clinics of North America · doi:10.1016/j.ocl.2009.02.004 · Cited by 68 · see citing works
Self-citationQuantitative gait analysis after medial unicompartmental knee arthroplasty for osteoarthritis
Webster, K. E., Wittwer, J. E., & Feller, J. A. (2003) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(03)00152-9 · Cited by 49 · see citing works
Chui, K. K., & Lusardi, M. M. (2010) · Journal of Geriatric Physical Therapy · doi:10.1519/jpt.0b013e3181ff262c · Cited by 44 · see citing works
Chui, K. K., & Lusardi, M. M. (2011) · PubMed · Cited by 37 · see citing works
Use of a Multimemory Stopwatch to Measure the Temporal Gait Parameters
Wall, J. C., & Scarbrough, J. (1997) · Journal of Orthopaedic and Sports Physical Therapy · doi:10.2519/jospt.1997.25.4.277 · Cited by 26 · see citing works
Chow, J. W., Yablon, S. A., Horn, T. S., & Stokić, D. S. (2010) · Brain Injury · doi:10.3109/02699052.2010.523053 · Cited by 23 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Validation of an IMU Gait Analysis Algorithm for Gait Monitoring in Daily Life Situations
Zhou, L., Tunca, C., Fischer, E., Brahms, C. M., Ersoy, C., Granacher, U., & Arnrich, B. (2020) · 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC) · doi:10.1109/embc44109.2020.9176827 · Cited by 63 · see citing works
Larsson, A., Weineland, S., Nissling, L., & Lilja, J. L. (2025) · JMIR Pediatrics and Parenting · doi:10.2196/59489 · Cited by 7 · see citing works
- Authors
- Lienhard, K., Schneider, D., & Maffiuletti, N. A.
- Affiliations
- Schulthess-Klinik (CH)
- Corresponding author
- Maffiuletti, Nicola A.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2012-07-18
- Volume
- 35
- Issue
- 4
- Pages
- 500-504
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2117925202
- Cited by
- 185
- References
- 19
- Citations by year
- 2026: 16 · 2025: 20 · 2024: 14 · 2023: 6 · 2022: 18 · 2021: 22 · 2020: 21 · 2019: 19 · 2018: 13 · 2017: 8 · 2016: 12 · 2015: 8 · 2014: 4 · 2013: 4
- FWCI
- 12.62
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Medical Engineering & Physics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Health Sciences › Medicine › Surgery › Total Knee Arthroplasty Outcomes
- Keywords
- OptoGait, spatiotemporal gait parameters, total knee arthroplasty, assessment validity, discriminant validity, concurrent validity, gait analysis, walking speed, cadence, cycle time, swing time, stance time, step length
- MeSH terms
- Aged, Female, Gait, Humans, Male, Orthopedics, Electrical Equipment and Supplies, Spatio-Temporal Analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review