Validation of an IMU Gait Analysis Algorithm for Gait Monitoring in Daily Life Situations
Open accessAbstract
Gait is an essential function for humans, and gait patterns in daily life provide meaningful information about a person's cognitive and physical health conditions. Inertial measurement units (IMUs) have emerged as a promising tool for low-cost, unobtrusive gait analysis. However, large varieties of IMU gait analysis algorithms and the lack of consensus for their validation make it difficult for researchers to assess the reliability of the algorithms for specific use cases. In daily life, individuals adapt their gait patterns in response to changes in the environment, making it necessary for IMU gait analysis algorithms to provide accurate measurements despite these gait variations. In this paper, we reviewed common types of IMU gait analysis algorithms and appropriate analysis methods to evaluate the accuracy of gait parameters extracted from IMU measurements. We then evaluated stride lengths and stride times calculated from a comprehensive double integration based IMU gait analysis algorithm using an optoelectric walkway as gold standard. In total, 729 strides from five healthy subjects and three different walking patterns were analyzed. Correlation analyses and Bland-Altman plots showed that this method is accurate and robust against large variations in walking patterns (stride length: correlation coefficient (r) was 0.99, root mean square error (RMSE) was 3% and average limits of agreement (LoA) was 6%; stride time: r was 0.95, RMSE was 4% and average LoA was 7%), making it suitable for gait evaluation in daily life situations. Due to the small sample size, our preliminary findings should be verified in future studies.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Physilog inertial sensors have good technical capability compared to reference systems in healthy and clinical settings.
“In general Physilog inertial sensors have good technical capability compared to reference systems in healthy and clinical settings (39, 40).”
From The instrumented single leg stance test detects early balance impairment in people with multiple sclerosis (2023) · cites this paper as [40]
The Experimental Setup identifies Physilog 5 IMUs and an OptoGait reference system; the Abstract reports accurate stride-length and stride-time estimates from the IMU-based algorithm. But the study tested five healthy subjects, not a clinical population, and used the sensors’ raw data rather than validating the manufacturer’s gait-analysis software. (LLM, conf=0.88)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Gait speed and survival in older adults.
Studenski, S. (2011) · JAMA · doi:10.1001/jama.2010.1923 · Cited by 4,558 · cited 1× · see citing works
“Gait is an important indicator of a person’s cognitive and physical health, and gait speed has been found to correlate with a person’s health status, functional decline, and even mortality [1][2].”
BackgroundGait Analysis: Normal and Pathological Function
(1992) · JAMA · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875 · see citing works
Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes
Aminian, K., Najafi, B., Büla, C., Leyvraz, P. F., & Robert, P. A. (2002) · Journal of Biomechanics · doi:10.1016/s0021-9290(02)00008-8 · Cited by 816 · see citing works
Gait Analysis, Normal and Pathological Function.
Simon, S. R. (1993) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-199303000-00027 · Cited by 501 · see citing works
3D gait assessment in young and elderly subjects using foot-worn inertial sensors
Mariani, B., Lenoble-Hoskovec, C., Rochat, S., Büla, C., Penders, J., & Aminian, K. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.07.003 · Cited by 364 · see citing works
Zaki, R. A., Bulgiba, A. M., Ismail, R., & Ismail, N. A. (2012) · PLoS ONE · doi:10.1371/journal.pone.0037908 · Cited by 303 · see citing works
Guidelines for clinical applications of spatio-temporal gait analysis in older adults
European GAITRite® Network Group, Kressig, R. W., & Beauchet, O. (2006) · Aging Clinical and Experimental Research · doi:10.1007/bf03327437 · Cited by 287 · see citing works
Validity of the Optogait photoelectric system for the assessment of spatiotemporal gait parameters
Lienhard, K., Schneider, D., & Maffiuletti, N. A. (2013) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.06.015 · Cited by 185 · see citing works
Dadashi, F., Mariani, B., Rochat, S., Büla, C., Santos‐Eggimann, B., & Aminian, K. (2013) · Sensors · doi:10.3390/s140100443 · Cited by 173 · see citing works
Mobile Stride Length Estimation With Deep Convolutional Neural Networks
Hannink, J., Kautz, T., Pasluosta, C. F., Barth, J., Schülein, S., Gassmann, K.-G., Klucken, J., & Eskofier, B. M. (2017) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2017.2679486 · Cited by 145 · see citing works
Inertial Sensor-Based Robust Gait Analysis in Non-Hospital Settings for Neurological Disorders
Tunca, C., Pehlivan, N., Ak, N., Bert Arnrich, A., Salur, G., & Ersoy, C. (2017) · Sensors · doi:10.3390/s17040825 · Cited by 142 · see citing works
Self-citationFerrari, A., Ginis, P., Hardegger, M., Casamassima, F., Rocchi, L., & Chiari, L. (2015) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2015.2457511 · Cited by 141 · see citing works
Lee, M. M., Song, C. H., Lee, K. J., Jung, S. W., Shin, D., & Shin, S. H. (2014) · Journal of Physical Therapy Science · doi:10.1589/jpts.26.81 · Cited by 134 · see citing works
Accurate Ambulatory Gait Analysis in Walking and Running Using Machine Learning Models
Zhang, H., Guo, Y. P., & Zanotto, D. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2958679 · Cited by 130 · see citing works
Inertial Measurement Unit-Based Estimation of Foot Trajectory for Clinical Gait Analysis
Ono, Y., Hori, K., Ora, H., Hirobe, Y., Mao, Y., Sawada, H., Inaba, A., Orimo, S., & Miyake, Y. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2019.01530 · Cited by 74 · see citing works
Yeo, S. S., & Park, G. Y. (2020) · Sensors · doi:10.3390/s20051343 · Cited by 56 · see citing works
Gait and its assessment in psychiatry.
Sanders, R. D., & Gillig, P. M. (2010) · PubMed Central · Cited by 50 · see citing works
A practical step length algorithm using lower limb angular velocities
Allseits, E., Agrawal, V., Lučarević, J., GAILEY, R. S., GAUNAURD, I. A., & Bennett, C. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.11.010 · Cited by 47 · see citing works
Flagged first, then by citations
1 of the 19 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Recent Advances in Quantitative Gait Analysis Using Wearable Sensors: A Review
Hutabarat, Y., Owaki, D., & Hayashibe, M. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3119658 · Cited by 99 · see citing works
A multi-sensor wearable system for the assessment of diseased gait in real-world conditions
Salis, F., Bertuletti, S., Bonci, T., Caruso, M., Scott, K., Alcock, L., Buckley, E. E., Gazit, E., Hansen, C., Schwickert, L., et al. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1143248 · Cited by 85 · see citing works
Prill, R., Walter, M., Królikowska, A., & Becker, R. (2021) · Sensors · doi:10.3390/s21248221 · Cited by 65 · see citing works
Sung, J., Han, S., Park, H. S., Cho, H.-M., Hwang, S., Park, J. W., & Youn, I. (2021) · Sensors · doi:10.3390/s22010053 · Cited by 61 · see citing works
Zhao, J. C., Zhang, S., Sun, Y., Zhou, N., Yu, H., Zhang, H., & Jia, D. (2022) · ACS Photonics · doi:10.1021/acsphotonics.2c00898 · Cited by 62 · see citing works
Mao, Y., Ogata, T., Ora, H., Tanaka, N., & Miyake, Y. (2021) · Scientific Reports · doi:10.1038/s41598-021-81009-w · Cited by 43 · see citing works
Validation of shoe-worn Gait Up Physilog®5 wearable inertial sensors in adolescents
Carroll, K., Kennedy, R. A., Koutoulas, V., Bui, M., & Kraan, C. M. (2021) · Gait & Posture · doi:10.1016/j.gaitpost.2021.09.203 · Cited by 41 · see citing works
Machine-Learning Based Determination of Gait Events from Foot-Mounted Inertial Units
Zago, M., Tarabini, M., Spiga, M. D., Ferrario, C., Bertozzi, F., Sforza, C., & Galli, M. (2021) · Sensors · doi:10.3390/s21030839 · Cited by 25 · see citing works
A Pilot Study to Validate a Wearable Inertial Sensor for Gait Assessment in Older Adults with Falls
Neira, G. G.-V., Álvarez, M. N., Hoyas, E. H., Jiménez, A. R., & Rodriguez‐Sanchez, M. C. (2021) · Sensors · doi:10.3390/s21134334 · Cited by 25 · see citing works
Measuring Spatiotemporal Parameters on Treadmill Walking Using Wearable Inertial System
Scataglini, S., Verwulgen, S., Roosens, E., Haelterman, R., & Tiggelen, D. V. (2021) · Sensors · doi:10.3390/s21134441 · Cited by 26 · see citing works
Evaluation of Hemiplegic Gait Based on Plantar Pressure and Inertial Sensors
Pan, Z., Gao, H., Chen, Y., Xie, Z., & Xie, L. (2023) · IEEE Sensors Journal · doi:10.1109/jsen.2023.3268669 · Cited by 22 · see citing works
González-Alonso, J., Oviedo-Pastor, D., Aguado, H. J., Pernas, F. J. D., González‐Ortega, D., & Martínez‐Zarzuela, M. (2021) · Sensors · doi:10.3390/s21196642 · Cited by 22 · see citing works
Motion Analysis of Football Kick Based on an IMU Sensor
Yu, C., Huang, T.-Y., & Ma, H. (2022) · Sensors · doi:10.3390/s22166244 · Cited by 21 · see citing works
Yu, C.-H., Yeh, C.-C., Lu, Y.-F., Lu, Y.-L., Wang, T., Lin, F. Y., & Lu, T. (2023) · Sensors · doi:10.3390/s23229040 · Cited by 15 · see citing works
Bailey, C. A., Mir-Orefice, A., Uchida, T. K., Nantel, J., & Graham, R. B. (2023) · Annals of Biomedical Engineering · doi:10.1007/s10439-023-03290-2 · Cited by 14 · see citing works
Berg-Hansen, P., Moen, S. M., Klyve, T. D., Gonzalez, V., Seeberg, T. M., Celius, E. G., Austeng, A., & Meyer, F. (2023) · Frontiers in Neurology · doi:10.3389/fneur.2023.1227374 · Cited by 12 · see citing works
“In general Physilog inertial sensors have good technical capability compared to reference systems in healthy and clinical settings (39, 40).”
BackgroundWeber, J. G., Ortigas-Vásquez, A., Sauer, A., Dupraz, I., Utz, M. J., Maas, A., & Grupp, T. M. (2024) · Bioengineering · doi:10.3390/bioengineering11100976 · Cited by 12 · see citing works
Casabona, A., Valle, M. S., Mangano, G. R. A., & Cioni, M. (2022) · Sensors · doi:10.3390/s22135001 · Cited by 11 · see citing works
Arm-CODA: A Data Set of Upper-limb Human Movement During Routine Examination
Combettes, S. W., Boniol, P., Mazarguil, A., Wang, D., Vaquero-Ramos, D., Chauveau, M., Oudre, L., Vayatis, N., Vidal, P., Rören, A., et al. (2024) · Image Processing On Line · doi:10.5201/ipol.2024.494 · Cited by 11 · see citing works
Design and validation of depth camera-based static posture assessment system
Xing, Q., Hong, R., Shen, Y., & Shen, Y. (2023) · iScience · doi:10.1016/j.isci.2023.107974 · Cited by 10 · see citing works
Lang, C., van Dieën, J. H., Brodie, M. A. D., Welzel, J., Maetzler, W., Singh, N. B., & Ravi, D. K. (2024) · Frontiers in Neurology · doi:10.3389/fneur.2024.1455692 · Cited by 10 · see citing works
Gait Phase Recognition Using Fuzzy Logic Regulation with Multisensor Data Fusion
Gao, W., & Zhenwei, Z. (2021) · Journal of Sensors · doi:10.1155/2021/8776059 · Cited by 10 · see citing works
Algorithm for Gait Parameters Estimation Based on Heel-Mounted Inertial Sensors
Luo, B., Wang, Z., Wang, D., Chen, L., & Ma, X. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3410402 · Cited by 9 · see citing works
Efficient Gait Analysis Using Deep Learning Techniques
Monica, K. M., & Parvathi, R. (2022) · Computers, materials & continua/Computers, materials & continua (Print) · doi:10.32604/cmc.2023.032273 · Cited by 9 · see citing works
Madrigal, J. A. B., Rodríguez, L. A. C., Pérez, E. C., Hernández-Rodríguez, P. R., & Sossa, H. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.104938 · Cited by 9 · see citing works
Ma, Z., Fang, L., Fang, C., Chen, F., Xing, S. P., Chai, B., Zheng, Z., & Wang, S. J. (2025) · Cell Reports Physical Science · doi:10.1016/j.xcrp.2025.102438 · Cited by 7 · see citing works
Single, M., Bruhin, L. C., Colombo, A., Möri, K., Gerber, S. M., Lahr, J., Krack, P., Klöppel, S., Müri, R. M., Mosimann, U. P., et al. (2024) · Sensors · doi:10.3390/s24041172 · Cited by 7 · see citing works
Do we still need to screen our patients?—Orthopaedic scoring based on motion tracking
Raab, D., Heitzer, F., Liaw, J. C., Müller, K., Weber, L., Flores, F. G., Kecskeméthy, A., Mayer, C. U., & Jäger, M. (2023) · International Orthopaedics · doi:10.1007/s00264-022-05670-0 · Cited by 6 · see citing works
Morris, M. A., Franck, C. T., & Madigan, M. L. (2024) · Gait & Posture · doi:10.1016/j.gaitpost.2024.11.001 · Cited by 6 · see citing works
Evaluating walkability across age groups and flooring materials using IMU sensors
Jo, D., & Kim, H. (2024) · Frontiers in Public Health · doi:10.3389/fpubh.2024.1509602 · Cited by 5 · see citing works
Motor Activity Sensorics for mHealth Support of Human Resilience in Daily Life
Meigal, A. Y., Gerasimova-Meigal, L. I., Rego, G. E., & Korzun, D. G. (2022) · Conference of Open Innovations Association (FRUCT) · doi:10.23919/fruct56874.2022.9953829 · Cited by 5 · see citing works
An Open-Source Wearable System for Real-Time Human Biomechanical Analysis
Hoegberg, Z. N., Donahue, S. R., & Major, M. J. (2025) · Sensors · doi:10.3390/s25092931 · Cited by 4 · see citing works
Summoogum, K., Das, D., Efstratiou, C., Palaniappan, R., Jayakumar, P., & Wall, J. (2023) · Wearable and Implantable Body Sensor Networks · doi:10.1109/bsn58485.2023.10331114 · Cited by 4 · see citing works
Carroll, K., Kennedy, R. A., Koutoulas, V., Werake, U., Bui, M., & Kraan, C. M. (2024) · Gait & Posture · doi:10.1016/j.gaitpost.2024.04.003 · Cited by 4 · see citing works
Kim, H., Kim, J. J., & Ko, J. (2021) · Sensors · doi:10.3390/s21227676 · Cited by 4 · see citing works
Ma, X., Shao, M., Feng, X.-W., Du, W., Yi, Q., Chi, P., & Li, H. (2025) · Sensors · doi:10.3390/s25175423 · Cited by 3 · see citing works
Diabetes Detection Using Gait Analysis and Machine Learning
Chee, L. Z., Hwong, H. H., & Sivakumar, S. (2023) · International Conference on Digital Applications, Transformation & Economy (ICDATE) · doi:10.1109/icdate58146.2023.10248507 · Cited by 3 · see citing works
Song, S., Fernandes, N. J., & Nordin, A. D. (2023) · Sensors · doi:10.3390/s23187945 · Cited by 3 · see citing works
d'Andrea, F., Taylor, P. N., Yang, K., & Heller, B. W. (2023) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2023.1225086 · Cited by 3 · see citing works
Kuś, M., Wasiuk-Zowada, D., Henke, M., Szefler–Derela, J., & Knapik, A. (2024) · Sensors · doi:10.3390/s24196417 · Cited by 3 · see citing works
Gait Monitoring Using An Ankle-Worn Stereo Camera System
Chen, J., Ke, J., Lu, F., Fernandes, J., King, B., Hu, Y. H., & Jiang, H. (2022) · Proceedings of IEEE Sensors/Proceedings of IEEE Sensors ... · doi:10.1109/sensors52175.2022.9967079 · Cited by 3 · see citing works
Reliable Gait Measurements Using Smartphone Vision Sensor
Irfan, M., & Suryadevara, N. K. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3487541 · Cited by 2 · see citing works
Unobtrusive measurement of gait parameters using seismographs: An observational study
Single, M., Bruhin, L. C., Naef, A. C., Krack, P., Nef, T., & Gerber, S. M. (2024) · Scientific Reports · doi:10.1038/s41598-024-64508-4 · Cited by 2 · see citing works
GCCRR: A Short Sequence Gait Cycle Segmentation Method Based on Ear-Worn IMU
Xu, Z., & Guo, Y. (2024) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/3675094.3680520 · Cited by 2 · see citing works
A Review on Neural Network based Gait Estimation Methods
Lee, J., Sivakumar, S., & Ning, L. W. (2022) · International Conference on Green Energy, Computing and Sustainable Technology (GECOST) · doi:10.1109/gecost55694.2022.10010660 · Cited by 2 · see citing works
Salis, F., Bertuletti, S., Bonci, T., Caruso, M., Scott, K., Alcock, L., Buckley, E. E., Gazit, E., Hansen, C., Schwickert, L., et al. (2023) · Research Square · doi:10.21203/rs.3.rs-2486943/v1 · Cited by 2 · see citing works
Peters, J., Bloomer, C., Tokarsky, A., Halloran, K. M., Bleakney, A., & Abou, L. (2025) · Disability and Rehabilitation Assistive Technology · doi:10.1080/17483107.2025.2499186 · Cited by 1 · see citing works
Adaptive Control Method for Gait Detection and Classification Devices with Inertial Measurement Unit
Kim, H., Kim, J. W., & Ko, J. (2023) · Sensors · doi:10.3390/s23146638 · Cited by 1 · see citing works
Gait Analysis for Parkinson’s Patients by using Wrist Acceleration
Hang, C. L. S., Sivakumar, S., Kitt, W. W., & Motalebi, F. (2023) · International Conference on Digital Applications, Transformation & Economy (ICDATE) · doi:10.1109/icdate58146.2023.10248734 · Cited by 1 · see citing works
Lower Limb Gait Estimation Using Foot Motion and Neural Network
Lee, J., Malik, I., Chee, A. L. T., & Sivakumar, S. (2023) · International Conference on Digital Applications, Transformation & Economy (ICDATE) · doi:10.1109/icdate58146.2023.10248823 · Cited by 1 · see citing works
A Lightweight Motion Function Analysis System based on Binocular Vision
Hu, H., Wang, C., Hou, Z., Chen, J., Xu, N., Huang, Y., Ma, Z., Zhang, Y., & Zhou, Y. (2024) · IEEE International Conference on Real-time Computing and Robotics (RCAR) · doi:10.1109/rcar61438.2024.10670891 · Cited by 1 · see citing works
Self Gait Assessment Using a Smartphone CameraPreprint
Irfan, M., & Suryadevara, N. K. (2023) · SSRN Electronic Journal · doi:10.2139/ssrn.4565919
Hussain, R., Zabach, B., & Hmra, D. (2024) · Research Square · doi:10.21203/rs.3.rs-4441212/v1
Fröhlich, W. D. R., Bittencourt, R., Rigo, S. J., Baptista, R. R., & Marcon, C. A. M. (2025) · IEEE Latin American Symposium on Circuits and Systems (LASCAS) · doi:10.1109/lascas64004.2025.10966287
A Review of Sensor-Based Gait Recognition
He, M. H., & Toa, C. K. (2024) · International Conference on Computing Innovation, Intelligence, Technologies and Education (CIITE) · doi:10.1109/ciite62244.2024.10987605
Raghuvanshi, A., Yadav, V. R., Kanetkar, M. A., & Lahiri, U. (2025) · International Conference on Electronics, AI and Computing (EAIC) · doi:10.1109/eaic66483.2025.11101396
Acasio, J. C., Wang, Y., Fehr, K. H., Hendershot, B. D., & Adamczyk, P. G. (2025) · Applied Sciences · doi:10.3390/app152312757
Vibrotactile feedback system based on the trunk angle for gait training in lower-limb amputees
Hussain, R., Zabach, B., & Hmra, D. (2026) · Research on Biomedical Engineering · doi:10.1007/s42600-026-00472-4
Estimation of the Knee Joint with Single-Camera Smartphone
Russo, M., Ricciardi, C., Romano, M., Santoriello, V., Ponsiglione, A. M., Amato, F., & Spadea, M. F. (2026) · Sensors · doi:10.3390/s26072148
S-Transform Based Method for Gait Analysis in Children Suffering from Cerebral Palsy
Omar, A., Rathore, H., Pradhan, P. M., Aich, S., Panda, P. K., Sharawat, I. K., & Neyaz, O. (2026) · Lecture notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering · doi:10.1007/978-3-032-16099-7_35
Problems of gait analysis standardization in the rehabilitation of orthopedic patients: a review
Somov, D. A., Makarova, M. R., Maiorov, E. A., Kostenko, E. V., & Pogonchenkova, I. V. (2026) · Bulletin of Rehabilitation Medicine · doi:10.38025/2078-1962-2026-25-3-93-102
IMU-based gait analysis methods: a systematic review of techniques for different body locations
Chen, L., Guo, R., Guo, R., Chen, Y., Wang, Y., Zhang, S., & Zhang, Q. (2026) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2026.1854615
X4Gait: Cross-Modal Supervision for Practical IMU-based Dual-Task Gait Recognition
Wu, P., Xu, H., Zhang, X., Xie, Z., & Ye, F. (2026) · IEEE/ACM Conference on Connected Health: Applications, Systems and Engineering Technologies · doi:10.1109/chase69719.2026.00040
- Authors
- Zhou, L., Tunca, C., Fischer, E., Brahms, C. M., Ersoy, C., Granacher, U., & Arnrich, B.
- Affiliations
- University of Potsdam (DE)
- Boğaziçi University (TR)
- Venue
- 2020 42nd Annual International Conference of the IEEE Engineering in Medicine & Biology Society (EMBC)
- Publisher
- IEEE
- Published
- 2020-07
- Volume
- 2020
- Pages
- 4229-4232
- ISSN
- 2375-7477 (ISSN-L)
- OpenAlex
- W3082879976
- Cited by
- 63
- References
- 19
- Citations by year
- 2026: 6 · 2025: 7 · 2024: 15 · 2023: 17 · 2022: 7 · 2021: 11
- FWCI
- 15.89
- Type
- conference paper
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Bundesministerium für Bildung und Forschung (01IS19066)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Gait Recognition and Analysis
- Health Sciences › Health Professions › Physical Therapy, Sports Therapy and Rehabilitation › Balance, Gait, and Falls Prevention
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Keywords
- inertial measurement unit, gait analysis, stride length, stride time, algorithm validation, walking patterns, wearable sensors
- MeSH terms
- Gait Analysis, Algorithms, Gait, Humans, Reproducibility of Results, Walking
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review