The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Automatic CT-ultrasound registration for diagnostic imaging and image-guided intervention
Abstract
The fusion of tracked ultrasound with CT has benefits for a variety of clinical applications, however extensive manual effort is usually required for correct registration. We developed new methods that allow one to simulate medical ultrasound from CT in real-time, reproducing the majority of ultrasonic imaging effects. They are combined with a robust similarity measure that assesses the correlation of a combination of signals extracted from CT with ultrasound, without knowing the influence of each signal. This serves as the foundation of a fully automatic registration, that aligns a 3D ultrasound sweep with the corresponding tomographic modality using a rigid or an affine transformation model, without any manual interaction. These techniques were evaluated in a study involving 25 patients with indeterminate lesions in liver and kidney. The clinical setup, acquisition and registration workflow is described, along with the evaluation of the registration accuracy with respect to physician-defined Ground Truth. Our new algorithm correctly registers without any manual interaction in 76% of the cases, the average RMS TRE over multiple target lesions throughout the liver is 8.1mm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Press, W. H., Teukolsky, S. A., Vetterling, W. T., & Flannery, B. P. (1994) · Cited by 15,411
Medical image analysis: progress over two decades and the challenges ahead
Duncan, J. S., & Ayache, N. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824822 · Cited by 4,140
The calibration of CT Hounsfield units for radiotherapy treatment planning
Schneider, U., Pedroni, E., & Lomax, A. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/1/009 · Cited by 1,093
Estimating 3-D location parameters using dual number quaternions
Walker, M. W., Shao, L., & Volz, R. A. (1991) · CVGIP: Image Understanding · doi:10.1016/1049-9660(91)90036-o · Cited by 402
Roche, A., Pennec, X., Malandain, G., & Ayache, N. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.959301 · Cited by 289
Rohlfing, T., Maurer, C. R., O'Dell, W. G., & Zhong, J. (2004) · Medical Physics · doi:10.1118/1.1644513 · Cited by 262
Essentials Of Ultrasound Physics
Zagzebski, J. A. (1996) · Cited by 240
Unifying maximum likelihood approaches in medical image registration
Roche, A., Malandain, G., & Ayache, N. (2000) · International Journal of Imaging Systems and Technology · doi:10.1002/(sici)1098-1098(2000)11:1<71::aid-ima8>3.0.co;2-5 · Cited by 223
Registration of freehand 3D ultrasound and magnetic resonance liver images
Penney, G. P., Blackall, J. M., Hamady, M. S., Sabharwal, T., Adam, A., & Hawkes, D. J. (2004) · Medical Image Analysis · doi:10.1016/j.media.2003.07.003 · Cited by 219
Khamene, A., Bloch, P., Wein, W., Svatos, M. M., & Sauer, F. (2005) · Medical Image Analysis · doi:10.1016/j.media.2005.06.002 · Cited by 130
Self-citation
Research works printed but not linked: 10
- Arai, 2006, Real-time virtual sonography (RVS) for breast imaging, Ultrasound in Medicine & Biology, 32, P107, 10.1016/j.ultrasmedbio.2006.02.399 · doi:10.1016/j.ultrasmedbio.2006.02.399
- Crocetti, 2008, Targeting liver lesions for radiofrequency ablation: an experimental feasibility study using a CT-US fusion imaging system, Investigative Radiology, 43, 33, 10.1097/RLI.0b013e31815597dc · doi:10.1097/rli.0b013e31815597dc
- Press, 1992
- Sheafor, 2000, Comparison of sonographic and ct guidance techniques: does ct fluoroscopy decrease procedure time?, American Journal of Roentgenology, 174, 939, 10.2214/ajr.174.4.1740939 · doi:10.2214/ajr.174.4.1740939
- Stippel, 2002, Experimental evaluation of accuracy of radiofrequency ablation using conventional ultrasound or a third-dimension navigation tool, Langenbecks Archives of Surgery, 387, 303, 10.1007/s00423-002-0315-9 · doi:10.1007/s00423-002-0315-9
- Wein, W., Khamene, A., 2008. Image-based method for in-vivo freehand ultrasound calibration. In: SPIE Medical Imaging 2008, San Diego. · doi:10.1117/12.769948
- Wein, W., Khamene, A., Clevert, D., Kutter, O., Navab, N., 2007a. Simulation and fully automatic multimodal registration of medical ultrasound. In: MICCAI 2007 Proceedings, vol. 4791 of Lecture Notes in Computer Science, Springer, pp. 136–143. · doi:10.1007/978-3-540-75757-3_17
- Wein, 2007, Integrating diagnostic B-mode ultrasonography into CT-based radiation treatment planning, IEEE Transactions on Medical Imaging, 26, 866, 10.1109/TMI.2007.895483 · doi:10.1109/tmi.2007.895483
- Wood, 2000, Radiofrequency ablation of 231 unresectable hepatic tumors: indications, limitations, and complications, Annals of Surgical Oncology, 7, 593, 10.1007/BF02725339 · doi:10.1007/bf02725339
- Zhu, Y., Magee, D., Ratnalingam, R., Kessel, D., 2007. A training system for ultrasound-guided needle insertion procedures. In: MICCAI 2007 Proceedings, vol. 4791 of Lecture Notes in Computer Science, Springer, pp. 566–574. · doi:10.1007/978-3-540-75757-3_69
Cited by
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“Wein et al. [364] simulated an US image in order to tackle the problem of CT-to-US rigid/affine registration.”
BackgroundA Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
Quicksilver: Fast predictive image registration – A deep learning approach
Yang, X., Kwitt, R., Styner, M., & Niethammer, M. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.008 · Cited by 630
A review of multimodal image matching: Methods and applications
Jiang, X., Ma, J., Xiao, G., Shao, Z., & Guo, X. (2021) · Information Fusion · doi:10.1016/j.inffus.2021.02.012 · Cited by 532
Towards realtime multimodal fusion for image-guided interventions using self-similarities
Heinrich, M. P., Jenkinson, M., Papież, B. W., Brady, S. M., & Schnabel, J. A. (2013) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-40811-3_24 · Cited by 176
Metadata
- Authors
- Wein, W., Brunke, S., Khamene, A., Callstrom, M. R., & Navab, N.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2008-10
- Volume
- 12
- Issue
- 5
- Pages
- 577-585
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2155634500
- Cited by
- 339
- References
- 14
- FWCI
- 33.41
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- doi.org/10.15223/policy-017 (stm-asf)
- doi.org/10.15223/policy-037 (stm-asf)
- doi.org/10.15223/policy-012 (stm-asf)
- doi.org/10.15223/policy-029 (stm-asf)
- doi.org/10.15223/policy-004 (stm-asf)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automatic CT-ultrasound registration for diagnostic imaging and image-guided intervention. https://app.cochat.ai/papers/10.1016/j.media.2008.06.006
- The paper
- Wein, W., Brunke, S., Khamene, A., Callstrom, M. R., & Navab, N. (2008). Automatic CT-ultrasound registration for diagnostic imaging and image-guided intervention. Medical Image Analysis. https://doi.org/10.1016/j.media.2008.06.006
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.