The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Rigid registration of 3-D ultrasound with MR images: a new approach combining intensity and gradient information
Abstract
We present a new image-based technique to rigidly register intraoperative three-dimensional ultrasound (US) with preoperative magnetic resonance (MR) images. Automatic registration is achieved by maximization of a similarity measure which generalizes the correlation ratio, and whose novelty is to incorporate multivariate information from the MR data (intensity and gradient). In addition, the similarity measure is built upon a robust intensity-based distance measure, which makes it possible to handle a variety of US artifacts. A cross-validation study has been carried out using a number of phantom and clinical data. This indicates that the method is quite robust and that the worst registration errors are of the order of the MR image resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robust Regression and Outlier Detection
Rousseeuw, P. J., & Leroy, A. M. (1987) · Wiley Series in Probability and Statistics · doi:10.1002/0471725382 · Cited by 5,609
Multimodality image registration by maximization of mutual information
Maes, F., Collignon, A., Vandermeulen, D., Marchal, G., & Suetens, P. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563664 · Cited by 4,547
A survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
Alignment by Maximization of Mutual Information
Viola, P., & Wells III, W. M. (1997) · International Journal of Computer Vision · doi:10.1023/a:1007958904918 · Cited by 2,610
An overlap invariant entropy measure of 3D medical image alignment
Studholme, C., Hill, D. L. G., & Hawkes, D. J. (1999) · Pattern Recognition · doi:10.1016/s0031-3203(98)00091-0 · Cited by 2,180
The correlation ratio as a new similarity measure for multimodal image registration
Roche, A., Malandain, G., Pennec, X., & Ayache, N. (1998) · Lecture Notes in Computer Science · doi:10.1007/bfb0056301 · Cited by 542
Self-citationBlock Matching: A General Framework to Improve Robustness of Rigid Registration of Medical Images
Ourselin, S., Roche, A., Prima, S., & Ayache, N. (2000) · Lecture Notes in Computer Science · doi:10.1007/978-3-540-40899-4_57 · Cited by 279
Self-citationMulti-modality image registration by maximization of mutual information
Maes, F., Vandermeulen, D., & Suetens, P. L. (2000) · Cited by 255
Intraoperative ultrasound for guidance and tissue shift correction in image‐guided neurosurgery
Comeau, R. M., Sadikot, A. F., Fenster, A., & Peters, T. M. (2000) · Medical Physics · doi:10.1118/1.598942 · Cited by 249
Unifying maximum likelihood approaches in medical image registration
Roche, A., Malandain, G., & Ayache, N. (2000) · International Journal of Imaging Systems and Technology · doi:10.1002/(sici)1098-1098(2000)11:1<71::aid-ima8>3.0.co;2-5 · Cited by 223
Self-citation
Cited by
Mutual-information-based registration of medical images: a survey
Pluim, J. P. W., Maintz, J. B. A., & Viergever, M. A. (2003) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2003.815867 · Cited by 2,890
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“[363] tackled ultrasound (US) to MR rigid registration by simulating an US image from the MR one.”
BackgroundHuman motion tracking for rehabilitation-A survey
Zhou, H., & Hu, H. (2008) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.09.001 · Cited by 813
Intrinsic Statistics on Riemannian Manifolds: Basic Tools for Geometric Measurements
Pennec, X. (2006) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-006-6228-4 · Cited by 751
Self-citationA review of multimodal image matching: Methods and applications
Jiang, X., Ma, J., Xiao, G., Shao, Z., & Guo, X. (2021) · Information Fusion · doi:10.1016/j.inffus.2021.02.012 · Cited by 532
Metadata
- Authors
- Roche, A., Pennec, X., Malandain, G., & Ayache, N.
- Venue
- IEEE Transactions on Medical Imaging
- Published
- 2001
- Volume
- 20
- Issue
- 10
- Pages
- 1038-1049
- ISSN
- 0278-0062 (ISSN-L)
- OpenAlex
- W2112773824
- Cited by
- 289
- References
- 17
- FWCI
- 20.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rigid registration of 3-D ultrasound with MR images: a new approach combining intensity and gradient information. https://app.cochat.ai/papers/10.1109/42.959301
- The paper
- Roche, A., Pennec, X., Malandain, G., & Ayache, N. (2001). Rigid registration of 3-D ultrasound with MR images: a new approach combining intensity and gradient information. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/42.959301
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.