The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
A 2D/3D correspondence building method for reconstruction of a patient-specific 3D bone surface model using point distribution models and calibrated X-ray images
Abstract
Constructing a 3D bone surface model from a limited number of calibrated 2D X-ray images (e.g. 2) and a 3D point distribution model is a challenging task, especially, when we would like to construct a patient-specific surface model of a bone with pathology. One of the key steps for such a 2D/3D reconstruction is to establish correspondences between the 2D images and the 3D model. This paper presents a 2D/3D correspondence building method based on a non-rigid 2D point matching process, which iteratively uses a symmetric injective nearest-neighbor mapping operator and 2D thin-plate splines based deformations to find a fraction of best matched 2D point pairs between features extracted from the X-ray images and those extracted from the 3D model. The estimated point pairs are then used to set up a set of 3D point pairs such that we turn a 2D/3D reconstruction problem to a 3D/3D one, whose solutions are well studied. Incorporating this 2D/3D correspondence building method, a 2D/3D reconstruction scheme combining a statistical instantiation with a regularized shape deformation has been developed. Comprehensive experiments on clinical datasets and on images of cadaveric femurs with both non-pathologic and pathologic cases are designed and conducted to evaluate the performance of the 2D/3D correspondence building method as well as that of the 2D/3D reconstruction scheme. Quantitative and qualitative evaluation results are given, which demonstrate the validity of the present method and scheme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
Turk, M., & Pentland, A. (1991) · Journal of Cognitive Neuroscience · doi:10.1162/jocn.1991.3.1.71 · Cited by 13,733
A new point matching algorithm for non-rigid registration
Chui, H., & Rangarajan, A. (2003) · Computer Vision and Image Understanding · doi:10.1016/s1077-3142(03)00009-2 · Cited by 1,560
Cited by
Mechanical behavior of regular open-cell porous biomaterials made of diamond lattice unit cells
Ahmadi, S. M., Campoli, G., Amin Yavari, S., Sajadi, B., Wauthle, R., Schrooten, J., Weinans, H., & Zadpoor, A. A. (2014) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2014.02.003 · Cited by 442
The Virtual Skeleton Database: An Open Access Repository for Biomedical Research and Collaboration
Kistler, M., Bonaretti, S., Pfahrer, M., Niklaus, R., & Büchler, P. (2013) · Journal of Medical Internet Research · doi:10.2196/jmir.2930 · Cited by 303
Chen, X., Graham, J., Hutchinson, C., & Muir, L. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2226740 · Cited by 26
Wang, H., Stout, D. B., & Chatziioannou, A. F. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.02.009 · Cited by 16
Metadata
- Authors
- Zheng, G., Gollmer, S., Schumann, S., Dong, X., Feilkas, T., & González Ballester, M. A.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2009-12
- Volume
- 13
- Issue
- 6
- Pages
- 883-899
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2031820365
- Cited by
- 158
- References
- 3
- FWCI
- 8.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A 2D/3D correspondence building method for reconstruction of a patient-specific 3D bone surface model using point distribution models and calibrated X-ray images. https://app.cochat.ai/papers/10.1016/j.media.2008.12.003
- The paper
- Zheng, G., Gollmer, S., Schumann, S., Dong, X., Feilkas, T., & González Ballester, M. A. (2009). A 2D/3D correspondence building method for reconstruction of a patient-specific 3D bone surface model using point distribution models and calibrated X-ray images. Medical Image Analysis. https://doi.org/10.1016/j.media.2008.12.003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.