High resolution cortical bone thickness measurement from clinical CT data
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
The distribution of cortical bone in the proximal femur is believed to be a critical component in determining fracture resistance. Current CT technology is limited in its ability to measure cortical thickness, especially in the sub-millimetre range which lies within the point spread function of today's clinical scanners. In this paper, we present a novel technique that is capable of producing unbiased thickness estimates down to 0.3mm. The technique relies on a mathematical model of the anatomy and the imaging system, which is fitted to the data at a large number of sites around the proximal femur, producing around 17,000 independent thickness estimates per specimen. In a series of experiments on 16 cadaveric femurs, estimation errors were measured as -0.01+/-0.58mm (mean+/-1std.dev.) for cortical thicknesses in the range 0.3-4mm. This compares with 0.25+/-0.69mm for simple thresholding and 0.90+/-0.92mm for a variant of the 50% relative threshold method. In the clinically relevant sub-millimetre range, thresholding increasingly fails to detect the cortex at all, whereas the new technique continues to perform well. The many cortical thickness estimates can be displayed as a colour map painted onto the femoral surface. Computation of the surfaces and colour maps is largely automatic, requiring around 15min on a modest laptop computer.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A method for registration of 3-D shapes
Besl, P. J., & McKay, N. D. (1992) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.121791 · Cited by 18,103 · cited 1×
“The co-registration was then refined using a fairly standard variant of the iterative closest point (ICP) algorithm (Besl and McKay, 1992), as illustrated in Fig.”
MethodFaires, J. D. (1978) · Cited by 6,711
The Levenberg-Marquardt algorithm: Implementation and theory
Moré, J. J. (1978) · Lecture Notes in Mathematics · doi:10.1007/bfb0067700 · Cited by 5,773 · cited 3×
“Optimization was performed using the Levenberg-Marquardt method (More, 1977).”
MethodInfluentialMedical image analysis: progress over two decades and the challenges ahead
Duncan, J. S., & Ayache, N. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824822 · Cited by 4,140
European guidance for the diagnosis and management of osteoporosis in postmenopausal women
Kanis, J. A., McCloskey, E. V., Johansson, H., Cooper, C., Rizzoli, R., Reginster, J.-Y., & on behalf of the Scientific Advisory Board of the European Society for Clinical and Economic Aspects of Osteoporosis and Osteoarthritis (ESCEO) and the Committee of Scientific Advisors of the International Osteoporosis Foundation (IOF) (2013) · Osteoporosis International · doi:10.1007/s00198-012-2074-y · Cited by 2,948 · cited 2×
“, 2008) but have low sensitivity (Kanis et al., 2008; Kaptoge et al., 2008; Sanders et al., 2006).”
BackgroundPredictive Value of BMD for Hip and Other Fractures
Johnell, O., Kanis, J. A., Oden, A., Johansson, H., De Laet, C., Delmas, P., Eisman, J. A., Fujiwara, S., Kroger, H., Mellstrom, D., et al. (2005) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.050304 · Cited by 1,445 · cited 1×
“Current imaging methods for predicting an individuals hip fracture risk use bone mineral density (BMD) estimates which are specific (Johnell et al., 2005; Kanis et al., 2008) but have low sensitivity (Kanis et al.”
BackgroundSambrook, P., & Cooper, C. (2006) · The Lancet · doi:10.1016/s0140-6736(06)68891-0 · Cited by 1,165
European guidance for the diagnosis and management of osteoporosis in postmenopausal women
Kanis, J. A., Burlet, N., Cooper, C., Delmas, P. D., Reginster, J.-Y., Borgstrom, F., Rizzoli, R., & on behalf of the European Society for Clinical and Economic Aspects of Osteoporosis and Osteoarthritis (ESCEO) (2008) · Osteoporosis International · doi:10.1007/s00198-008-0560-z · Cited by 776
Buie, H. R., Campbell, G. M., Klinck, R. J., MacNeil, J. A., & Boyd, S. K. (2007) · Bone · doi:10.1016/j.bone.2007.07.007 · Cited by 601 · cited 1×
“Such studies explain why straightforward thickness estimation techniques, such as those based on thresholding (Buie et al., 2007; Hangartner, 2007) or the 50% relative threshold method (Prevrhal et al.”
BackgroundParker, M., & Johansen, A. (2006) · BMJ · doi:10.1136/bmj.333.7557.27 · Cited by 428
Cited by
Mirzaali, M. J., Schwiedrzik, J. J., Thaiwichai, S., Best, J. P., Michler, J., Zysset, P. K., & Wolfram, U. (2016) · Bone · doi:10.1016/j.bone.2015.11.018 · Cited by 325
“As a remarkable proportion of physiological loading in the ageing5 hip is carried by the cortical shell (Holzer et al., 2009), it is important to investi-6 gate its role in the fracture resistance and strength of whole bones (Schaffler and7 Burr, 1984; Treece et al., 2010; Zebaze et al., 2010).”
BackgroundZebaze, R., Ghasem-Zadeh, A., Mbala, A., & Seeman, E. (2013) · Bone · doi:10.1016/j.bone.2013.01.007 · Cited by 195
“Many algorithms use attenuation profile curve analysis but they only segment bone into two, cortical and trabecular, compartments [20–24].”
BackgroundBeavers, K. M., Walkup, M. P., Weaver, A. A., Lenchik, L., Kritchevsky, S. B., Nicklas, B. J., Ambrosius, W. T., Stitzel, J. D., Register, T. C., Shapses, S. A., et al. (2018) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.3555 · Cited by 69
Metadata
- Authors
- Treece, G. M., Gee, A. H., Mayhew, P. M., & Poole, K. E. S.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2010-06
- Volume
- 14
- Issue
- 3
- Pages
- 276-290
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2015052481
- Cited by
- 233
- References
- 28
- FWCI
- 6.55
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.