Nonrigid registration of dynamic medical imaging data using nD+t B-splines and a groupwise optimization approach
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265 · cited 1×
“A B-spline transformation model is used (Rueckert et al., 1999) because the compact support of B-splines keeps the running time reasonably low for higher dimensional imaging data.”
MethodElastix: a toolbox for intensity-based medical image registration
Klein, S., Staring, M., Murphy, K., Viergever, M. A., & Pluim, J. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035616 · Cited by 4,311 · cited 1×
“The method has been implemented as an extension to the open source registration package elastix (Klein et al., 2010) and is freely available for download.”
MethodSelf-citation
Cited by
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“FFDs have been extended to tackle multiple-image registration where hard constraints are employed to define a reference domain [146]–[149].”
BackgroundThe Insight ToolKit image registration framework
Avants, B. B., Tustison, N. J., Stauffer, M., Song, G., Wu, B., & Gee, J. C. (2014) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2014.00044 · Cited by 658
“…applications increase (Rueckert et al., 1999; van Dalen et al., 2004; Miller et al., 2005; Shelton et al., 2005; Chen et al., 2008; Baloch and Davatzikos, 2009; Cheung and Krishnan, 2009; Peyrat et al., 2010; Fedorov et al., 2011; Kikinis and Pieper, 2011; Metz et al., 2011; Murphy et al., 2011).”
Live imaging of astrocyte responses to acute injury reveals selective juxtavascular proliferation
Bardehle, S., Krüger, M., Buggenthin, F., Schwausch, J., Ninkovic, J., Clevers, H., Snippert, H. J., Theis, F. J., Meyer-Luehmann, M., Bechmann, I., et al. (2013) · Nature Neuroscience · doi:10.1038/nn.3371 · Cited by 426
Respiratory motion models: A review
McClelland, J. R., Hawkes, D. J., Schaeffter, T., & King, A. P. (2013) · Medical Image Analysis · doi:10.1016/j.media.2012.09.005 · Cited by 385
SimpleElastix: A User-Friendly, Multi-lingual Library for Medical Image Registration
Marstal, K., Berendsen, F., Staring, M., & Klein, S. (2016) · 2016 IEEE Conference on Computer Vision and Pattern Recognition Workshops (CVPRW) · doi:10.1109/cvprw.2016.78 · Cited by 325
Self-citationDopamine neurons projecting to the posterior striatum form an anatomically distinct subclass
Menegas, W., Bergan, J. F., Ogawa, S. K., Isogai, Y., Umadevi Venkataraju, K., Osten, P., Uchida, N., & Watabe-Uchida, M. (2015) · eLife · doi:10.7554/elife.10032 · Cited by 322
MRF-Based Deformable Registration and Ventilation Estimation of Lung CT
Heinrich, H. P., Jenkinson, M., Brady, M., & Schnabel, J. A. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2246577 · Cited by 311
Menegas, W., Babayan, B. M., Uchida, N., & Watabe-Uchida, M. (2017) · eLife · doi:10.7554/elife.21886 · Cited by 265
Multi-Modal Medical Image Registration with Full or Partial Data: A Manifold Learning Approach
Bashiri, F. S., Baghaie, A., Rostami, R., Yu, Z., & D’Souza, R. M. (2018) · Journal of Imaging · doi:10.3390/jimaging5010005 · Cited by 46
Metadata
- Authors
- Metz, C. T., Klein, S., Schaap, M., van Walsum, T., & Niessen, W. J.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2011-04
- Volume
- 15
- Issue
- 2
- Pages
- 238-249
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2018919812
- Cited by
- 236
- References
- 2
- FWCI
- 22.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.