The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Non-local statistical label fusion for multi-atlas segmentation
Open accessAbstract
Multi-atlas segmentation provides a general purpose, fully-automated approach for transferring spatial information from an existing dataset (“atlases”) to a previously unseen context (“target”) through image registration. The method to resolve voxelwise label conflicts between the registered atlases (“label fusion”) has a substantial impact on segmentation quality. Ideally, statistical fusion algorithms (e.g., STAPLE) would result in accurate segmentations as they provide a framework to elegantly integrate models of rater performance. The accuracy of statistical fusion hinges upon accurately modeling the underlying process of how raters err. Despite success on human raters, current approaches inaccurately model multi-atlas behavior as they fail to seamlessly incorporate exogenous intensity information into the estimation process. As a result, locally weighted voting algorithms represent the de facto standard fusion approach in clinical applications. Moreover, regardless of the approach, fusion algorithms are generally dependent upon large atlas sets and highly accurate registration as they implicitly assume that the registered atlases form a collectively unbiased representation of the target. Herein, we propose a novel statistical fusion algorithm, Non-Local STAPLE (NLS). NLS reformulates the STAPLE framework from a non-local means perspective in order to learn what label an atlas would have observed, given perfect correspondence. Through this reformulation, NLS (1) seamlessly integrates intensity into the estimation process, (2) provides a theoretically consistent model of multi-atlas observation error, and (3) largely diminishes the need for large atlas sets and very high-quality registrations. We assess the sensitivity and optimality of the approach and demonstrate significant improvement in two empirical multi-atlas experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fischl, B., Salat, D. H., Busa, E., Albert, M., Dieterich, M., Haselgrove, C., van der Kouwe, A., Killiany, R., Kennedy, D., Klaveness, S., et al. (2002) · Neuron · doi:10.1016/s0896-6273(02)00569-x · Cited by 8,610
A Non-Local Algorithm for Image Denoising
Buades, A., Coll, B., & Morel, J.-M. (2005) · 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05) · doi:10.1109/cvpr.2005.38 · Cited by 7,616
Ashburner, J., & Friston, K. J. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2005.02.018 · Cited by 7,507
Nonrigid registration using free-form deformations: application to breast mr images
Rueckert, D., Sonoda, L. I., Hayes, C., Hill, D. L. G., Leach, M. O., & Hawkes, D. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.796284 · Cited by 5,265
Warfield, S. K., Zou, K. H., & Wells, W. M. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.828354 · Cited by 2,072
Multi-Atlas Segmentation with Joint Label Fusion
Wang, H., Suh, J. W., Das, S. R., Pluta, J. B., Craige, C., & Yushkevich, P. A. (2013) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2012.143 · Cited by 796
Atlas Renormalization for Improved Brain MR Image Segmentation Across Scanner Platforms
Han, X., & Fischl, B. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.893282 · Cited by 215 · cited 1×
“Yet, the accuracy of single-atlas based methods is limited due to the bias concerns and lack of correspondence to the target (Ashburner and Friston, 2005; Han and Fischl, 2007).”
Background
Cited by
Multi-atlas segmentation of biomedical images: A survey
Iglesias, J. E., & Sabuncu, M. R. (2015) · Medical Image Analysis · doi:10.1016/j.media.2015.06.012 · Cited by 667
Doshi, J., Erus, G., Ou, Y., Resnick, S. M., Gur, R. C., Gur, R. E., Satterthwaite, T. D., Furth, S., & Davatzikos, C. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2015.11.073 · Cited by 309
“…with particular emphasis on atlas selection and robust and accurate fusion of the warped atlas labels (Aljabar et al., 2009; Lötjönen et al., 2010; Sabuncu et al., 2010; Landman et al., 2011; Leung et al., 2011; Asman and Landman, 2013; Cardoso et al., 2013; Zikic et al., 2014; Wu et al., 2015).”
3D whole brain segmentation using spatially localized atlas network tiles
Huo, Y., Xu, Z., Xiong, Y., Aboud, K., Parvathaneni, P., Bao, S., Bermudez, C., Resnick, S. M., Cutting, L. E., & Landman, B. A. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.03.041 · Cited by 309
Self-citationFast and sequence-adaptive whole-brain segmentation using parametric Bayesian modeling
Puonti, O., Iglesias, J. E., & Van Leemput, K. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.09.011 · Cited by 258
AssemblyNet: A large ensemble of CNNs for 3D whole brain MRI segmentation
Coupé, P., Mansencal, B., Clément, M., Giraud, R., Denis de Senneville, B., Ta, V.-T., Lepetit, V., & Manjon, J. V. (2020) · NeuroImage · doi:10.1016/j.neuroimage.2020.117026 · Cited by 206
Metadata
- Authors
- Asman, A. J., & Landman, B. A.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2013-02
- Volume
- 17
- Issue
- 2
- Pages
- 194-208
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2085091083
- Cited by
- 217
- References
- 7
- FWCI
- 17.70
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Non-local statistical label fusion for multi-atlas segmentation. https://app.cochat.ai/papers/10.1016/j.media.2012.10.002
- The paper
- Asman, A. J., & Landman, B. A. (2013). Non-local statistical label fusion for multi-atlas segmentation. Medical Image Analysis. https://doi.org/10.1016/j.media.2012.10.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.