Automated drusen segmentation and quantification in SD-OCT images
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Spectral domain optical coherence tomography (SD-OCT) is a useful tool for the visualization of drusen, a retinal abnormality seen in patients with age-related macular degeneration (AMD); however, objective assessment of drusen is thwarted by the lack of a method to robustly quantify these lesions on serial OCT images. Here, we describe an automatic drusen segmentation method for SD-OCT retinal images, which leverages a priori knowledge of normal retinal morphology and anatomical features. The highly reflective and locally connected pixels located below the retinal nerve fiber layer (RNFL) are used to generate a segmentation of the retinal pigment epithelium (RPE) layer. The observed and expected contours of the RPE layer are obtained by interpolating and fitting the shape of the segmented RPE layer, respectively. The areas located between the interpolated and fitted RPE shapes (which have nonzero area when drusen occurs) are marked as drusen. To enhance drusen quantification, we also developed a novel method of retinal projection to generate an en face retinal image based on the RPE extraction, which improves the quality of drusen visualization over the current approach to producing retinal projections from SD-OCT images based on a summed-voxel projection (SVP), and it provides a means of obtaining quantitative features of drusen in the en face projection. Visualization of the segmented drusen is refined through several post-processing steps, drusen detection to eliminate false positive detections on consecutive slices, drusen refinement on a projection view of drusen, and drusen smoothing. Experimental evaluation results demonstrate that our method is effective for drusen segmentation. In a preliminary analysis of the potential clinical utility of our methods, quantitative drusen measurements, such as area and volume, can be correlated with the drusen progression in non-exudative AMD, suggesting that our approach may produce useful quantitative imaging biomarkers to follow this disease and predict patient outcome.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bilateral Filtering for Gray and Color Images
Tomasi, C., & Manduchi, R. (2002) · Sixth International Conference on Computer Vision (IEEE Cat. No.98CH36271) · doi:10.1109/iccv.1998.710815 · Cited by 8,177 · cited 2×
“In this paper, we adopted bilateral filtering (Tomasi and Manduchi, 1998): hðxÞ ¼ k À1 ðxÞ Z 1 À1 Z 1 À1 f ðnÞcðn; xÞsðf ðnÞ; f ðxÞÞdn ð1Þ where f and h are the input and output images, respectively. c(n, x) measures the geometric closeness between the neighborhood center x and a nearby point n.”
MethodA Non-Local Algorithm for Image Denoising
Buades, A., Coll, B., & Morel, J.-M. (2005) · 2005 IEEE Computer Society Conference on Computer Vision and Pattern Recognition (CVPR'05) · doi:10.1109/cvpr.2005.38 · Cited by 7,616 · cited 1×
“Although the bilateral filtering may not be optimal for SD-OCT image denoising compared with the patch-based methods (Buades et al., 2005; Fang et al., 2012), it has a relatively low time complexity and acceptable performance for the needs of our segmentation algorithm.”
BackgroundAge-related macular degeneration
Jager, R. D., Mieler, W. F., & Miller, J. W. (2008) · New England Journal of Medicine · doi:10.1056/nejmra0801537 · Cited by 1,379
(2005) · Archives of Ophthalmology · doi:10.1001/archopht.123.11.1484 · Cited by 739
Drusen in Age-Related Macular Degeneration
Abdelsalam, A., Del Priore, L., & Zarbin, M. A. (1999) · Survey of Ophthalmology · doi:10.1016/s0039-6257(99)00072-7 · Cited by 352
Cited by
Artificial intelligence in retina
Schmidt-Erfurth, U., Sadeghipour, A., Gerendas, B. S., Waldstein, S. M., & Bogunović, H. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.07.004 · Cited by 779
“…may benefit from quantification and has been solved with AI approaches is the volume of drusen in early to intermediate AMD, as this appears to be an indicator for the risk of disease progression (Abdelfattah et al., 2016; Chen et al., 2013; Bogunovic et al., 2017a; Schmidt-Erfurth et al., 2018b).”
BackgroundMethodThe Integration of Artificial Intelligence into Clinical Practice
Karalis, V. D. (2024) · Applied Biosciences · doi:10.3390/applbiosci3010002 · Cited by 255
“These algorithms leverage fundus images and spectral-domain optical coherence tomograph to enhance the diagnosis and treatment [135].”
Balaratnasingam, C., Yannuzzi, L. A., Curcio, C. A., Morgan, W. H., Querques, G., Capuano, V., Souied, E., Jung, J., & Freund, K. B. (2016) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.16-19816 · Cited by 144
Metadata
- Authors
- Chen, Q., Leng, T., Zheng, L., Kutzscher, L., Ma, J., de Sisternes, L., & Rubin, D. L.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2013-12
- Volume
- 17
- Issue
- 8
- Pages
- 1058-1072
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2000015918
- Cited by
- 126
- References
- 5
- FWCI
- 5.94
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.