The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Trainable COSFIRE filters for vessel delineation with application to retinal images
Open accessAbstract
Retinal imaging provides a non-invasive opportunity for the diagnosis of several medical pathologies. The automatic segmentation of the vessel tree is an important pre-processing step which facilitates subsequent automatic processes that contribute to such diagnosis. We introduce a novel method for the automatic segmentation of vessel trees in retinal fundus images. We propose a filter that selectively responds to vessels and that we call B-COSFIRE with B standing for bar which is an abstraction for a vessel. It is based on the existing COSFIRE (Combination Of Shifted Filter Responses) approach. A B-COSFIRE filter achieves orientation selectivity by computing the weighted geometric mean of the output of a pool of Difference-of-Gaussians filters, whose supports are aligned in a collinear manner. It achieves rotation invariance efficiently by simple shifting operations. The proposed filter is versatile as its selectivity is determined from any given vessel-like prototype pattern in an automatic configuration process. We configure two B-COSFIRE filters, namely symmetric and asymmetric, that are selective for bars and bar-endings, respectively. We achieve vessel segmentation by summing up the responses of the two rotation-invariant B-COSFIRE filters followed by thresholding. The results that we achieve on three publicly available data sets (DRIVE: Se=0.7655, Sp=0.9704; STARE: Se=0.7716, Sp=0.9701; CHASE_DB1: Se=0.7585, Sp=0.9587) are higher than many of the state-of-the-art methods. The proposed segmentation approach is also very efficient with a time complexity that is significantly lower than existing methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Cited by
MISSFormer: An Effective Transformer for 2D Medical Image Segmentation
Huang, X., Deng, Z., Li, D., Yuan, X., & Fu, Y. (2023) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2022.3230943 · Cited by 594
Bi-Directional ConvLSTM U-Net with Densley Connected Convolutions
Azad, R., Asadi-Aghbolaghi, M., Fathy, M., & Escalera, S. (2019) · 2019 IEEE/CVF International Conference on Computer Vision Workshop (ICCVW) · doi:10.1109/iccvw.2019.00052 · Cited by 474
Zhao, Y., Rada, L., Chen, K., Harding, S. P., & Zheng, Y. (2015) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2015.2409024 · Cited by 391
A Three-Stage Deep Learning Model for Accurate Retinal Vessel Segmentation
Yan, Z., Yang, X., & Cheng, K.-T. (2019) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2018.2872813 · Cited by 341
Metadata
- Authors
- Azzopardi, G., Strisciuglio, N., Vento, M., & Petkov, N.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2015-01
- Volume
- 19
- Issue
- 1
- Pages
- 46-57
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2109037308
- Cited by
- 713
- References
- 1
- FWCI
- 28.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Trainable COSFIRE filters for vessel delineation with application to retinal images. https://app.cochat.ai/papers/10.1016/j.media.2014.08.002
- The paper
- Azzopardi, G., Strisciuglio, N., Vento, M., & Petkov, N. (2015). Trainable COSFIRE filters for vessel delineation with application to retinal images. Medical Image Analysis. https://doi.org/10.1016/j.media.2014.08.002
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.