Trainable COSFIRE filters for vessel delineation with application to retinal images
Open accessAbstract
Retinal imaging provides a non-invasive opportunity for the diagnosis of several medical pathologies. The automatic segmentation of the vessel tree is an important pre-processing step which facilitates subsequent automatic processes that contribute to such diagnosis. We introduce a novel method for the automatic segmentation of vessel trees in retinal fundus images. We propose a filter that selectively responds to vessels and that we call B-COSFIRE with B standing for bar which is an abstraction for a vessel. It is based on the existing COSFIRE (Combination Of Shifted Filter Responses) approach. A B-COSFIRE filter achieves orientation selectivity by computing the weighted geometric mean of the output of a pool of Difference-of-Gaussians filters, whose supports are aligned in a collinear manner. It achieves rotation invariance efficiently by simple shifting operations. The proposed filter is versatile as its selectivity is determined from any given vessel-like prototype pattern in an automatic configuration process. We configure two B-COSFIRE filters, namely symmetric and asymmetric, that are selective for bars and bar-endings, respectively. We achieve vessel segmentation by summing up the responses of the two rotation-invariant B-COSFIRE filters followed by thresholding. The results that we achieve on three publicly available data sets (DRIVE: Se=0.7655, Sp=0.9704; STARE: Se=0.7716, Sp=0.9701; CHASE_DB1: Se=0.7585, Sp=0.9587) are higher than many of the state-of-the-art methods. The proposed segmentation approach is also very efficient with a time complexity that is significantly lower than existing methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ridge-based vessel segmentation in color images of the retina
Staal, J., Abramoff, M. D., Niemeijer, M., Viergever, M. A., & van Ginneken, B. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825627 · Cited by 4,202
Medical image analysis: progress over two decades and the challenges ahead
Duncan, J. S., & Ayache, N. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824822 · Cited by 4,140
Adaptive histogram equalization and its variations
Pizer, S. M., Amburn, E. P., Austin, J. D., Cromartie, R., Geselowitz, A., Greer, T., ter Haar Romeny, B., Zimmerman, J. B., & Zuiderveld, K. (1987) · Computer Vision, Graphics, and Image Processing · doi:10.1016/s0734-189x(87)80186-x · Cited by 4,012
Locating blood vessels in retinal images by piecewise threshold probing of a matched filter response
Hoover, A. D., Kouznetsova, V., & Goldbaum, M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.845178 · Cited by 2,582
Detection of blood vessels in retinal images using two-dimensional matched filters
Chaudhuri, S., Chatterjee, S., Katz, N., Nelson, M., & Goldbaum, M. (1989) · IEEE Transactions on Medical Imaging · doi:10.1109/42.34715 · Cited by 1,668
Retinal vessel segmentation using the 2-D Gabor wavelet and supervised classification
Soares, J. V. B., Leandro, J. J. G., Cesar, R. M., Jelinek, H. F., & Cree, M. J. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879967 · Cited by 1,497
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
An Ensemble Classification-Based Approach Applied to Retinal Blood Vessel Segmentation
Fraz, M. M., Remagnino, P., Hoppe, A., Uyyanonvara, B., Rudnicka, A. R., Owen, C. G., & Barman, S. A. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2205687 · Cited by 1,031
Marín, D., Aquino, A., Gegundez-Arias, M. E., & Bravo, J. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2064333 · Cited by 929
Mendonca, A. M., & Campilho, A. (2006) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2006.879955 · Cited by 921
Segmentation of vessel-like patterns using mathematical morphology and curvature evaluation
Zana, F., & Klein, J.-C. (2001) · IEEE Transactions on Image Processing · doi:10.1109/83.931095 · Cited by 862
Retinal Blood Vessel Segmentation Using Line Operators and Support Vector Classification
Ricci, E., & Perfetti, R. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.898551 · Cited by 818
Comparative study of retinal vessel segmentation methods on a new publicly available database
Niemeijer, M., Staal, J., van Ginneken, B., Loog, M., & Abramoff, M. D. (2004) · SPIE Proceedings · doi:10.1117/12.535349 · Cited by 790
Quantitative analysis of cat retinal ganglion cell response to visual stimuli
Rodieck, R. W. (1965) · Vision Research · doi:10.1016/0042-6989(65)90033-7 · Cited by 764
Jiang, X., & Mojon, D. (2003) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2003.1159954 · Cited by 679
A survey of palmprint recognition
Kong, A., Zhang, D., & Kamel, M. (2009) · Pattern Recognition · doi:10.1016/j.patcog.2009.01.018 · Cited by 545
Owen, C. G., Rudnicka, A. R., Mullen, R., Barman, S. A., Monekosso, D., Whincup, P. H., Ng, J., & Paterson, C. (2009) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.08-3018 · Cited by 465
An Active Contour Model for Segmenting and Measuring Retinal Vessels
Al-Diri, B., Hunter, A., & Steel, D. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2017941 · Cited by 431
Segmentation of blood vessels from red-free and fluorescein retinal images
Martinez-Perez, M. E., Hughes, A. D., Thom, S. A., Bharath, A. A., & Parker, K. H. (2007) · Medical Image Analysis · doi:10.1016/j.media.2006.11.004 · Cited by 416
A fuzzy vessel tracking algorithm for retinal images based on fuzzy clustering
Tolias, Y. A., & Panas, S. M. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.700738 · Cited by 365
Heneghan, C. (2002) · Medical Image Analysis · doi:10.1016/s1361-8415(02)00058-0 · Cited by 353
An improved matched filter for blood vessel detection of digital retinal images
Al-Rawi, M., Qutaishat, M., & Arrar, M. (2007) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2006.03.003 · Cited by 305
Harding, S. P., Broadbent, D. M., Neoh, C., White, M. C., & Vora, J. (1995) · BMJ · doi:10.1136/bmj.311.7013.1131 · Cited by 295
Gang, L., Chutatape, O., & Krishnan, S. M. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.979356 · Cited by 294
The detection and quantification of retinopathy using digital angiograms
Zhou, L., Rzeszotarski, M. S., Singerman, L. J., & Chokreff, J. M. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363106 · Cited by 292
General Retinal Vessel Segmentation Using Regularization-Based Multiconcavity Modeling
Lam, B. S. Y., Gao, Y., & Liew, A. W.-C. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2043259 · Cited by 275
A Novel Method for the Automatic Grading of Retinal Vessel Tortuosity
Grisan, E., Foracchia, M., & Ruggeri, A. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.904657 · Cited by 260
Color retinal image enhancement using CLAHE
Setiawan, A. W., Mengko, T. R., Santoso, O. S., & Suksmono, A. B. (2013) · International Conference on ICT for Smart Society · doi:10.1109/ictss.2013.6588092 · Cited by 235
Retinal blood vessel detection and tracking by matched Gaussian and Kalman filters
Chutatape, O., Zheng, L., & Krishnan, S. M. (2002) · Proceedings of the 20th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. Vol.20 Biomedical Engineering Towards the Year 2000 and Beyond (Cat. No.98CH36286) · doi:10.1109/iembs.1998.746160 · Cited by 228
Cinsdikici, M. G., & Aydın, D. (2009) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2009.04.005 · Cited by 210
Trainable COSFIRE Filters for Keypoint Detection and Pattern Recognition
Azzopardi, G., & Azzopardi, N. (2012) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2012.106 · Cited by 135
Self-citationAzzopardi, G., & Petkov, N. (2012) · Biological Cybernetics · doi:10.1007/s00422-012-0486-6 · Cited by 123
Self-citationIrvin, G. E., Casagrande, V. A., & Norton, T. T. (1993) · Visual Neuroscience · doi:10.1017/s0952523800003758 · Cited by 113
Azzopardi, G., & Petkov, N. (2012) · Pattern Recognition Letters · doi:10.1016/j.patrec.2012.11.002 · Cited by 94
Self-citationXu, X., Bonds, A. B., & Casagrande, V. A. (2002) · Visual Neuroscience · doi:10.1017/s0952523802196027 · Cited by 39
von Wendt, G., Heikkila, K. V., & Summanen, P. A. (1999) · Acta Ophthalmologica Scandinavica · doi:10.1034/j.1600-0420.1999.770607.x · Cited by 20
Cited by
CE-Net: Context Encoder Network for 2D Medical Image Segmentation
Gu, Z., Cheng, J., Fu, H., Zhou, K., Hao, H., Zhao, Y., Zhang, T., Gao, S., & Liu, J. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2903562 · Cited by 2,267
Segmenting Retinal Blood Vessels WithDeep Neural Networks
Liskowski, P., & Krawiec, K. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2546227 · Cited by 890
DUNet: A deformable network for retinal vessel segmentation
Jin, Q., Meng, Z., Pham, T. D., Chen, Q., Wei, L., & Su, R. (2019) · Knowledge-Based Systems · doi:10.1016/j.knosys.2019.04.025 · Cited by 867
Recurrent residual U-Net for medical image segmentation
Alom, M. Z., Yakopcic, C., Hasan, M., Taha, T. M., & Asari, V. K. (2019) · Journal of Medical Imaging · doi:10.1117/1.jmi.6.1.014006 · Cited by 850
MISSFormer: An Effective Transformer for 2D Medical Image Segmentation
Huang, X., Deng, Z., Li, D., Yuan, X., & Fu, Y. (2023) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2022.3230943 · Cited by 594
Metadata
- Authors
- Azzopardi, G., Strisciuglio, N., Vento, M., & Petkov, N.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2015-01
- Volume
- 19
- Issue
- 1
- Pages
- 46-57
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2109037308
- Cited by
- 713
- References
- 36
- FWCI
- 28.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.