The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
The status of augmented reality in laparoscopic surgery as of 2016
Open accessAbstract
• We review the state of the art about laparoscopic augmented reality with 270+ recent references. • We highlight that most methods consist in a static registration followed by augmentation updates. • We propose a clear classification of all methods and weigh pros and cons for each of them. • This survey is comprehensive and self-contained thanks to various backgrounds on related topics. This article establishes a comprehensive review of all the different methods proposed by the literature concerning augmented reality in intra-abdominal minimally invasive surgery (also known as laparoscopic surgery). A solid background of surgical augmented reality is first provided in order to support the survey. Then, the various methods of laparoscopic augmented reality as well as their key tasks are categorized in order to better grasp the current landscape of the field. Finally, the various issues gathered from these reviewed approaches are organized in order to outline the remaining challenges of augmented reality in laparoscopic surgery .
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A flexible new technique for camera calibration
Zhang, Z. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.888718 · Cited by 15,004
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
3D shape perception from combined depth cues in human visual cortex
Welchman, A. E., Deubelius, A., Conrad, V., Bülthoff, H. H., & Kourtzi, Z. (2005) · Nature Neuroscience · doi:10.1038/nn1461 · Cited by 183
Enhanced-Reality Video Fluorescence: A Real-Time Assessment of Intestinal Viability
Diana, M., Noll, E., Diemunsch, P., Dallemagne, B., Benahmed, M. A., Agnus, V., Soler, L., Barry, B., Namer, I. J., Demartines, N., et al. (2014) · Annals of Surgery · doi:10.1097/sla.0b013e31828d4ab3 · Cited by 168
Self-citationVisual SLAM for Handheld Monocular Endoscope
Grasa, O. G., Bernal, E., Casado, S., Gil, I., & Montiel, J. M. M. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2282997 · Cited by 155
Vision-based Navigation in Image-Guided Interventions
Mirota, D. J., Ishii, M., & Hager, G. D. (2011) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124757 · Cited by 137
Cited by
Lungu, A. J., Swinkels, W., Claesen, L., Tu, P., Egger, J., & Chen, X. (2021) · Expert Review of Medical Devices · doi:10.1080/17434440.2021.1860750 · Cited by 269
Augmented Reality for Robotics: A Review
Makhataeva, Z., & Varol, H. (2020) · Robotics · doi:10.3390/robotics9020021 · Cited by 266
Fernández del Amo, I., Erkoyuncu, J. A., Roy, R., Palmarini, R., & Onoufriou, D. (2018) · Computers in Industry · doi:10.1016/j.compind.2018.08.007 · Cited by 234
Application of artificial intelligence in surgery
Zhou, X.-Y., Guo, Y., Shen, M., & Yang, G.-Z. (2020) · Frontiers of Medicine · doi:10.1007/s11684-020-0770-0 · Cited by 181
Metadata
- Authors
- Bernhardt, S., Nicolau, S. A., Soler, L., & Doignon, C.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2017-04
- Volume
- 37
- Pages
- 66-90
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2582073395
- Cited by
- 314
- References
- 6
- FWCI
- 15.61
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The status of augmented reality in laparoscopic surgery as of 2016. https://app.cochat.ai/papers/10.1016/j.media.2017.01.007
- The paper
- Bernhardt, S., Nicolau, S. A., Soler, L., & Doignon, C. (2017). The status of augmented reality in laparoscopic surgery as of 2016. Medical Image Analysis. https://doi.org/10.1016/j.media.2017.01.007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.