Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 34 of the 37 references it cites were found in a registry or an index.

Visual SLAM for Handheld Monocular Endoscope

Grasa, Oscar G., Bernal, Ernesto, Casado, Santiago, Gil, Ismael, Montiel, J. M. M. · 2014 · IEEE Transactions on Medical Imaging

Abstract

Simultaneous localization and mapping (SLAM) methods provide real-time estimation of 3-D models from the sole input of a handheld camera, routinely in mobile robotics scenarios. Medical endoscopic sequences mimic a robotic scenario in which a handheld camera (monocular endoscope) moves along an unknown trajectory while observing an unknown cavity. However, the feasibility and accuracy of SLAM methods have not been extensively validated with human in vivo image sequences. In this work, we propose a monocular visual SLAM algorithm tailored to deal with medical image sequences in order to provide an up-to-scale 3-D map of the observed cavity and the endoscope trajectory at frame rate. The algorithm is validated over synthetic data and human in vivo sequences corresponding to 15 laparoscopic hernioplasties where accurate ground-truth distances are available. It can be concluded that the proposed procedure is: 1) noninvasive, because only a standard monocular endoscope and a surgical tool are used; 2) convenient, because only a hand-controlled exploratory motion is needed; 3) fast, because the algorithm provides the 3-D map and the trajectory in real time; 4) accurate, because it has been validated with respect to ground-truth; and 5) robust to inter-patient variability, because it has performed successfully over the validation sequences.

Overview

Integrity signals

Registry

Crossref · 10.1109/tmi.2013.2282997

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 37 references

Research works printed but not linked: 2

  1. gil, 2011, Augmented reality and 3-D measurement for monocular laparoscopic abdominal wall hernia repair, 46th Cong Eur Soc Surg Res, 98, 1
  2. grasa, 2009, EKF monocular SLAM 3-D modeling, measuring and augmented reality from endoscope image sequences, Proc 5th Workshop AMI-ARCS 12th Int Conf MICCAI, 102

Cited by

See all 155

Metadata

Authors
Grasa, O. G., Bernal, E., Casado, S., Gil, I., & Montiel, J. M. M.
Affiliations
  • Hospital Clínico Universitario Lozano Blesa (ES)
  • Universidad de Zaragoza (ES)
Venue
IEEE Transactions on Medical Imaging
Published
2014-01
Volume
33
Issue
1
Pages
135-146
ISSN
  • 0278-0062 (ISSN-L)
  • 1558-254X
OpenAlex
W1967329161
Cited by
155
References
37
Citations by year
2026: 11 · 2025: 15 · 2024: 10 · 2023: 17 · 2022: 9 · 2021: 20 · 2020: 17 · 2019: 12 · 2018: 9 · 2017: 17 · 2016: 7 · 2015: 4 · 2014: 6
FWCI
9.11
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Medical Imaging (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Robotics and Sensor-Based Localization
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Advanced Vision and Imaging
  • Physical Sciences › Earth and Planetary Sciences › Geology › 3D Surveying and Cultural Heritage
Keywords
visual SLAM, handheld camera, 3D reconstruction, laparoscopic hernia repair, real-time mapping, interpatient variability
MeSH terms
Algorithms, Endoscopy, Hernia, Humans, Image Enhancement, Image Interpretation, Computer-Assisted, Miniaturization, Pattern Recognition, Automated, Sensitivity and Specificity, User-Computer Interface, Video Recording, Reproducibility of Results, Imaging, Three-Dimensional, Surgery, Computer-Assisted, Herniorrhaphy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Visual SLAM for Handheld Monocular Endoscope. https://app.cochat.ai/papers/10.1109/tmi.2013.2282997
The paper
Grasa, O. G., Bernal, E., Casado, S., Gil, I., & Montiel, J. M. M. (2014). Visual SLAM for Handheld Monocular Endoscope. IEEE Transactions on Medical Imaging. https://doi.org/10.1109/tmi.2013.2282997

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.