Towards intelligent robust detection of anatomical structures in incomplete volumetric data
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
HighlightsMulti‐scale DRL with robust statistical shape modeling for anatomy detection.Multi‐scale processing enables real‐time speed and high detection accuracy.Robust and principled recognition of anatomy that is missing from the field‐of‐view.Extensive experiments on up to 50 anatomical landmarks and over 5000 3D‐CT scans. Graphical abstract Figure. No caption available. ABSTRACT Robust and fast detection of anatomical structures represents an important component of medical image analysis technologies. Current solutions for anatomy detection are based on machine learning, and are generally driven by suboptimal and exhaustive search strategies. In particular, these techniques do not effectively address cases of incomplete data, i.e., scans acquired with a partial field‐of‐view. We address these challenges by following a new paradigm, which reformulates the detection task to teaching an intelligent artificial agent how to actively search for an anatomical structure. Using the principles of deep reinforcement learning with multi‐scale image analysis, artificial agents are taught optimal navigation paths in the scale‐space representation of an image, while accounting for structures that are missing from the field‐of‐view. The spatial coherence of the observed anatomical landmarks is ensured using elements from statistical shape modeling and robust estimation theory. Experiments show that our solution outperforms marginal space deep learning, a powerful deep learning method, at detecting different anatomical structures without any failure. The dataset contains 5043 3D‐CT volumes from over 2000 patients, totaling over 2,500,000 image slices. In particular, our solution achieves 0% false‐positive and 0% false‐negative rates at detecting whether the landmarks are captured in the field‐of‐view of the scan (excluding all border cases), with an average detection accuracy of 2.78 mm. In terms of runtime, we reduce the detection‐time of the marginal space deep learning method by 20–30 times to under 40 ms, an unmatched performance for high resolution incomplete 3D‐CT data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Artifacts in CT: Recognition and Avoidance
Barrett, J. F., & Keat, N. (2004) · RadioGraphics · doi:10.1148/rg.246045065 · Cited by 1,688
Christ, P. F., Elshaer, M. E. A., Ettlinger, F., Tatavarty, S., Bickel, M., Bilic, P., Rempfler, M., Armbruster, M., Hofmann, F., D’Anastasi, M., et al. (2016) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-46723-8_48 · Cited by 625
Multi-Scale Deep Reinforcement Learning for Real-Time 3D-Landmark Detection in CT Scans
Ghesu, F.-C., Georgescu, B., Zheng, Y., Grbic, S., Maier, A., Hornegger, J., & Comaniciu, D. (2019) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.2017.2782687 · Cited by 310
Self-citationAutomatic 3D liver location and segmentation via convolutional neural network and graph cut
Lu, F., Wu, F., Hu, P., Peng, Z., & Kong, D. (2017) · International Journal of Computer Assisted Radiology and Surgery · doi:10.1007/s11548-016-1467-3 · Cited by 284
Marginal space deep learning: efficient architecture for volumetric image parsing
Ghesu, F. C., Krubasik, E., Georgescu, B., Singh, V., Zheng, Y., Hornegger, J., & Comaniciu, D. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2538802 · Cited by 142
Cited by
Artificial Intelligence in Cardiovascular Imaging
Dey, D., Slomka, P. J., Leeson, P., Comaniciu, D., Shrestha, S., Sengupta, P. P., & Marwick, T. H. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.12.054 · Cited by 680
Self-citationReinforcement Learning in Healthcare: A Survey
Yu, C., Liu, J., Nemati, S., & Yin, G. (2023) · ACM Computing Surveys · doi:10.1145/3477600 · Cited by 628
Integrating spatial configuration into heatmap regression based CNNs for landmark localization
Payer, C., Štern, D., Bischof, H., & Urschler, M. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.03.007 · Cited by 365
Reinforcement learning for intelligent healthcare applications: A survey
Coronato, A., Naeem, M., De Pietro, G., & Paragliola, G. (2020) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2020.101964 · Cited by 320
Deep reinforcement learning in medical imaging: A literature review
Zhou, S. K., Le, H. N., Luu, K., V Nguyen, H., & Ayache, N. (2021) · Medical Image Analysis · doi:10.1016/j.media.2021.102193 · Cited by 215
Metadata
- Authors
- Ghesu, F. C., Georgescu, B., Grbic, S., Maier, A., Hornegger, J., & Comaniciu, D.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2018-08
- Volume
- 48
- Pages
- 203-213
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2810465590
- Cited by
- 42
- References
- 5
- FWCI
- 2.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.