The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Coronary artery centerline extraction in cardiac CT angiography using a CNN-based orientation classifier
Open accessAbstract
&NA; Coronary artery centerline extraction in cardiac CT angiography (CCTA) images is a prerequisite for evaluation of stenoses and atherosclerotic plaque. In this work, we propose an algorithm that extracts coronary artery centerlines in CCTA using a convolutional neural network (CNN). In the proposed method, a 3D dilated CNN is trained to predict the most likely direction and radius of an artery at any given point in a CCTA image based on a local image patch. Starting from a single seed point placed manually or automatically anywhere in a coronary artery, a tracker follows the vessel centerline in two directions using the predictions of the CNN. Tracking is terminated when no direction can be identified with high certainty. The CNN is trained using manually annotated centerlines in training images. No image preprocessing is required, so that the process is guided solely by the local image values around the tracker's location. The CNN was trained using a training set consisting of 8 CCTA images with a total of 32 manually annotated centerlines provided in the MICCAI 2008 Coronary Artery Tracking Challenge (CAT08). Evaluation was performed within the CAT08 challenge using a test set consisting of 24 CCTA test images in which 96 centerlines were extracted. The extracted centerlines had an average overlap of 93.7% with manually annotated reference centerlines. Extracted centerline points were highly accurate, with an average distance of 0.21 mm to reference centerline points. Based on these results the method ranks third among 25 publicly evaluated methods in CAT08. In a second test set consisting of 50 CCTA scans acquired at our institution (UMCU), an expert placed 5448 markers in the coronary arteries, along with radius measurements. Each marker was used as a seed point to extract a single centerline, which was compared to the other markers placed by the expert. This showed strong correspondence between extracted centerlines and manually placed markers. In a third test set containing 36 CCTA scans from the MICCAI 2014 Challenge on Automatic Coronary Calcium Scoring (orCaScore), fully automatic seeding and centerline extraction was evaluated using a segment‐wise analysis. This showed that the algorithm is able to fully‐automatically extract on average 92% of clinically relevant coronary artery segments. Finally, the limits of agreement between reference and automatic artery radius measurements were found to be below the size of one voxel in both the CAT08 dataset and the UMCU dataset. Extraction of a centerline based on a single seed point required on average 0.4 ± 0.1 s and fully automatic coronary tree extraction required around 20 s. The proposed method is able to accurately and efficiently determine the direction and radius of coronary arteries based on information derived directly from the image data. The method can be trained with limited training data, and once trained allows fast automatic or interactive extraction of coronary artery trees from CCTA images.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Adam: A Method for Stochastic Optimization
Kingma, D. P., & Ba, J. (2014) · arXiv · doi:10.48550/arxiv.1412.6980 · Cited by 98,946
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786
Multi-scale context aggregation by dilated convolutions
Yu, F., & Koltun, V. (2015) · arXiv · doi:10.48550/arxiv.1511.07122 · Cited by 7,738
WaveNet: a generative model for raw audio
Oord, A. V. D., Dieleman, S., Zen, H., Simonyan, K., Vinyals, O., Graves, A., Kalchbrenner, N., Senior, A., & Kavukcuoglu, K. (2016) · arXiv · doi:10.48550/arxiv.1609.03499 · Cited by 4,911
Neural Machine Translation in Linear Time
Kalchbrenner, N., Espeholt, L., Simonyan, K., Oord, A. V. D., Graves, A., & Kavukcuoglu, K. (2016) · arXiv · doi:10.48550/arxiv.1610.10099 · Cited by 414 · cited 1×
“…with increasing levels of dilated convolutions have previously successfully extended receptive fields in 1D signal processing for audio generation and machine translation (Kalchbrenner et al., 2016; van den Oord et al., 2016), and analysis of 2D images (Yu and Koltun, 2016; Wolterink et al., 2017).”
BackgroundWolterink, J. M., Leiner, T., de Vos, B. D., van Hamersvelt, R. W., Viergever, M. A., & Išgum, I. (2016) · Medical Image Analysis · doi:10.1016/j.media.2016.04.004 · Cited by 321
Self-citation
Cited by
Zhou, S. K., Greenspan, H., Davatzikos, C., Duncan, J. S., Van Ginneken, B., Madabhushi, A., Prince, J. L., Rueckert, D., & Summers, R. M. (2021) · Proceedings of the IEEE · doi:10.1109/jproc.2021.3054390 · Cited by 1,118
Deep Learning for Cardiac Image Segmentation: A Review
Chen, C., Qin, C., Qiu, H., Tarroni, G., Duan, J., Bai, W., & Rueckert, D. (2020) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2020.00025 · Cited by 869
Zreik, M., van Hamersvelt, R. W., Wolterink, J. M., Leiner, T., Viergever, M. A., & Isgum, I. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2883807 · Cited by 282
Self-citationHanneman, K., Playford, D., Dey, D., van Assen, M., Mastrodicasa, D., Cook, T. S., Gichoya, J. W., Williamson, E. E., Rubin, G. D., & on behalf of the American Heart Association Council on Cardiovascular Radiology and Intervention; and Council on Lifelong Congenital Heart Disease and Heart Health in the Young (2024) · Circulation · doi:10.1161/cir.0000000000001202 · Cited by 72
Marey, A., Serdysnki, K. C., Killeen, B. D., Unberath, M., & Umair, M. (2024) · BJR|Artificial Intelligence · doi:10.1093/bjrai/ubae008 · Cited by 7
Metadata
- Authors
- Wolterink, J. M., van Hamersvelt, R. W., Viergever, M. A., Leiner, T., & Išgum, I.
- Venue
- Medical Image Analysis
- Publisher
- Elsevier BV
- Published
- 2019-01
- Volume
- 51
- Pages
- 46-60
- ISSN
- 1361-8415 (ISSN-L)
- OpenAlex
- W2895401428
- Cited by
- 207
- References
- 7
- FWCI
- 11.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coronary artery centerline extraction in cardiac CT angiography using a CNN-based orientation classifier. https://app.cochat.ai/papers/10.1016/j.media.2018.10.005
- The paper
- Wolterink, J. M., van Hamersvelt, R. W., Viergever, M. A., Leiner, T., & Išgum, I. (2019). Coronary artery centerline extraction in cardiac CT angiography using a CNN-based orientation classifier. Medical Image Analysis. https://doi.org/10.1016/j.media.2018.10.005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.