Preparation and evaluation of heparin-immobilized poly (lactic acid) (PLA) membrane for hemodialysis
The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Designing materials for biology and medicine
Langer, R., & Tirrell, D. A. (2004) · Nature · doi:10.1038/nature02388 · Cited by 3,198
Poly(lactic acid) modifications
Rasal, R. M., Janorkar, A. V., & Hirt, D. E. (2010) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2009.12.003 · Cited by 2,204 · cited 1×
“Poly (lactic acid) or polylactide (PLA) is the most extensively researched and utilized biodegradable and renewable thermoplastic bio-based polyester, with great potential to replace conventional petrochemical-based polymers [7–9].”
BackgroundPoly(lactic acid) crystallization
Saeidlou, S., Huneault, M. A., Li, H., & Park, C. B. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.07.005 · Cited by 1,606 · cited 1×
“Poly (lactic acid) or polylactide (PLA) is the most extensively researched and utilized biodegradable and renewable thermoplastic bio-based polyester, with great potential to replace conventional petrochemical-based polymers [7–9].”
BackgroundPoly(lactic acid) fiber: An overview
Gupta, B., Revagade, N., & Hilborn, J. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.01.005 · Cited by 1,360 · cited 1×
“Poly (lactic acid) or polylactide (PLA) is the most extensively researched and utilized biodegradable and renewable thermoplastic bio-based polyester, with great potential to replace conventional petrochemical-based polymers [7–9].”
BackgroundLate degradation tissue response to poly(?-lactide) bone plates and screws
Bergsma, J. (1995) · Biomaterials · doi:10.1016/0142-9612(95)91092-d · Cited by 799 · cited 1×
“The biocompatibility of bio-based PLA also stirred up considerably discussion for the extensive application of sutures [17], devices for bone fracture fixation [18], and meshes for tissues engineering [19,20].”
BackgroundOxidant-induced dopamine polymerization for multifunctional coatings
Wei, Q., Zhang, F., Li, J., Li, B., & Zhao, C. (2010) · Polymer Chemistry · doi:10.1039/c0py00215a · Cited by 759
Jiang, J., Zhu, L., Zhu, L., Zhu, B., & Xu, Y. (2011) · Langmuir · doi:10.1021/la202877k · Cited by 750
Mechanism of the anticoagulant action of heparin
Bj�rk, I., & Lindahl, U. (1982) · Molecular and Cellular Biochemistry · doi:10.1007/bf00421226 · Cited by 494 · cited 1×
“Researches stated that, with the synergistic effect of platelet factor III (AT3), heparin could not only act on thrombin to suppress the conversion reaction from fibrinogen to fibrin, but also prevent platelet adhesion and aggregation on the materials surface [24].”
BackgroundJiang, J.-H., Zhu, L.-P., Li, X.-L., Xu, Y.-Y., & Zhu, B.-K. (2010) · Journal of Membrane Science · doi:10.1016/j.memsci.2010.08.017 · Cited by 365 · cited 3×
“They assumed that the membranes with polydopamine layer will adsorb fewer platelets [22], but stronger platelet adhesion was occurred to all polydopamine-coated PLA membrane within our study.”
BackgroundResultInfluentialChen, J.-P., & Su, C.-H. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.08.015 · Cited by 354 · cited 1×
“The biocompatibility of bio-based PLA also stirred up considerably discussion for the extensive application of sutures [17], devices for bone fracture fixation [18], and meshes for tissues engineering [19,20].”
Background
Cited by
Ren, X., Feng, Y., Guo, J., Wang, H., Li, Q., Yang, J., Hao, X., Lv, J., Ma, N., & Li, W. (2015) · Chemical Society Reviews · doi:10.1039/c4cs00483c · Cited by 573
Antifouling membrane surface construction: Chemistry plays a critical role
Zhao, X., Zhang, R., Liu, Y., He, M., Su, Y., Gao, C., & Jiang, Z. (2018) · Journal of Membrane Science · doi:10.1016/j.memsci.2018.01.039 · Cited by 442
Surface engineering of polymer membranes via mussel-inspired chemistry
Yang, H.-C., Luo, J., Lv, Y., Shen, P., & Xu, Z.-K. (2015) · Journal of Membrane Science · doi:10.1016/j.memsci.2015.02.027 · Cited by 406
Materials from Mussel-Inspired Chemistry for Cell and Tissue Engineering Applications
Madhurakkat Perikamana, S. K., Lee, J., Lee, Y. B., Shin, Y. M., Lee, E. J., Mikos, A. G., & Shin, H. (2015) · Biomacromolecules · doi:10.1021/acs.biomac.5b00852 · Cited by 283
Biomimetic and bioinspired membranes: Preparation and application
Zhao, J., Zhao, X., Jiang, Z., Li, Z., Fan, X., Zhu, J., Wu, H., Su, Y., Yang, D., Pan, F., et al. (2014) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2014.06.001 · Cited by 200
Progress in heparin and heparin-like/mimicking polymer-functionalized biomedical membranes
Cheng, C., Sun, S., & Zhao, C. (2014) · J. Mater. Chem. B · doi:10.1039/c4tb01390e · Cited by 169
Controllable transition from finger-like pores to inter-connected pores of PLLA membranes
Gao, A., Liu, F., Shi, H., & Xue, L. (2015) · Journal of Membrane Science · doi:10.1016/j.memsci.2015.01.004 · Cited by 88
Self-citation
Metadata
- Authors
- Gao, A., Liu, F., & Xue, L.
- Venue
- Journal of Membrane Science
- Publisher
- Elsevier BV
- Published
- 2014-02
- Volume
- 452
- Pages
- 390-399
- ISSN
- 0376-7388 (ISSN-L)
- OpenAlex
- W2146611485
- Cited by
- 180
- References
- 33
- FWCI
- 10.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.