CoChat

Switchable solvent based liquid phase microextraction of trace lead and cadmium from environmental and biological samples prior to graphite furnace atomic absorption spectrometry detection

Zhang, Si, Chen, Beibei, He, Man, Hu, Bin · 2018 · Microchemical Journal
Cited by 64

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

A switchable hydrophilicity solvent (SHS) based liquid phase microextraction (LPME) method was proposed for the preconcentration of trace Pb (II) and Cd (II) followed by graphite furnace atomic absorption spectrometry (GFAAS) detection. The SHS of protonated triethylamine carbonate (P-TEA-C) was synthesized and applied as the extractant, which is environmentally friendly and low cost. Pb (II) and Cd (II) in ammonium pyrrolidine dithiocarbamate (APDC) complex form was extracted into the triethylamine (TEA) phase by converting P-TEA-C to TEA. The vortex led to the rapid formation of fine droplets of the extractant in the aqueous solution, and enlarged contact surface between both immiscible liquids. The factors affecting the microextraction procedure, including sample pH, APDC concentration, volume of SHS and NaOH, sample volume and matrix effect were investigated. Under the optimal conditions, enrichment factor of 50 was achieved with consumption of 10 mL aqueous sample, and detection limits of 16 and 3.9 ng L−1 were obtained for Pb (II) and Cd (II), respectively. The accuracy of the proposed method was validated by the analysis of Certified Reference Materials of GSBZ50009-88 environmental water, GBW07605 tea and GBW07601(GSH-1) human hair. The method was also successfully applied for determination of Pb (II) and Cd (II) in water, tea and human hair samples.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.microc.2018.03.017

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 64

Metadata

Authors
Zhang, S., Chen, B., He, M., & Hu, B.
Venue
Microchemical Journal
Publisher
Elsevier BV
Published
2018-06
Volume
139
Pages
380-385
ISSN
0026-265X (ISSN-L)
OpenAlex
W2790435358
Cited by
64
References
4
FWCI
4.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Switchable solvent based liquid phase microextraction of trace lead and cadmium from environmental and biological samples prior to graphite furnace atomic absorption spectrometry detection. https://app.cochat.ai/papers/10.1016/j.microc.2018.03.017
The paper
Zhang, S., Chen, B., He, M., & Hu, B. (2018). Switchable solvent based liquid phase microextraction of trace lead and cadmium from environmental and biological samples prior to graphite furnace atomic absorption spectrometry detection. Microchemical Journal. https://doi.org/10.1016/j.microc.2018.03.017

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.