Stability and mechanical evaluation of bovine pericardium cross-linked with polyurethane prepolymer in aqueous medium
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The present study investigates the potential use of non-catalyzed water-soluble blocked polyurethane prepolymer (PUP) as a bifunctional cross-linker for collagenous scaffolds. The effect of concentration (5, 10, 15 and 20%), time (4, 6, 12 and 24 h), medium volume (50, 100, 200 and 300%) and pH (7.4, 8.2, 9 and 10) over stability, microstructure and tensile mechanical behavior of acellular pericardial matrix was studied. The cross-linking index increased up to 81% while the denaturation temperature increased up to 12 °C after PUP crosslinking. PUP-treated scaffold resisted the collagenase degradation (0.167±0.14 mmol/g of liberated amine groups vs. 598±60 mmol/g for non-cross-linked matrix). The collagen fiber network was coated with PUP while viscoelastic properties were altered after cross-linking. The treatment of the pericardial scaffold with PUP allows (i) different densities of cross-linking depending of the process parameters and (ii) tensile properties similar to glutaraldehyde method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Acellular vascular tissues: natural biomaterials for tissue repair and tissue engineering
Schmidt, C. E., & Baier, J. M. (2000) · Biomaterials · doi:10.1016/s0142-9612(00)00148-4 · Cited by 762
Cited by
Processing of collagen based biomaterials and the resulting materials properties
Meyer, M. (2019) · BioMedical Engineering OnLine · doi:10.1186/s12938-019-0647-0 · Cited by 539
“Water-based systems or DMSO were used to stabilize pericardium by polyurethane prepolymers which still possess reactive isocyanate groups [354, 418].”
MethodMammalian Pericardium‐Based Bioprosthetic Materials in Xenotransplantation and Tissue Engineering
Grebenik, E. A., Gafarova, E. R., Istranov, L. P., Istranova, E. V., Ma, X., Xu, J., Guo, W., Atala, A., & Timashev, P. S. (2020) · Biotechnology Journal · doi:10.1002/biot.201900334 · Cited by 30
Walker, S., Dittfeld, C., Jakob, A., Schönfelder, J., König, U., & Tugtekin, S.-M. (2022) · The Thoracic and Cardiovascular Surgeon · doi:10.1055/s-0040-1705100 · Cited by 11
Metadata
- Authors
- Mendoza-Novelo, B., Alvarado-Castro, D. I., Mata-Mata, J. L., Cauich-Rodríguez, J. V., Vega-González, A., Jorge-Herrero, E., Rojo, F. J., & Guinea, G. V.
- Venue
- Materials Science and Engineering: C
- Publisher
- Elsevier BV
- Published
- 2013-05
- Volume
- 33
- Issue
- 4
- Pages
- 2392-2398
- ISSN
- 0928-4931 (ISSN-L)
- OpenAlex
- W2072419493
- Cited by
- 35
- References
- 1
- FWCI
- 1.32
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stability and mechanical evaluation of bovine pericardium cross-linked with polyurethane prepolymer in aqueous medium. https://app.cochat.ai/papers/10.1016/j.msec.2013.02.001
- The paper
- Mendoza-Novelo, B., Alvarado-Castro, D. I., Mata-Mata, J. L., Cauich-Rodríguez, J. V., Vega-González, A., Jorge-Herrero, E., Rojo, F. J., & Guinea, G. V. (2013). Stability and mechanical evaluation of bovine pericardium cross-linked with polyurethane prepolymer in aqueous medium. Materials Science and Engineering: C. https://doi.org/10.1016/j.msec.2013.02.001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.