CoChat

Three-dimensional printing and in vitro evaluation of poly(3-hydroxybutyrate) scaffolds functionalized with osteogenic growth peptide for tissue engineering

Open access
Saska, Sybele, Pires, Luana Carla, Cominotte, Mariana Aline, Mendes, Larissa Souza, de Oliveira, Marcelo Fernandes, Maia, Izaque Alves, da Silva, Jorge Vicente Lopes, Ribeiro, Sidney José Lima, Cirelli, Joni Augusto · 2018 · Materials Science and Engineering: C
Cited by 94

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Poly(3-hydroxybutyrate) (PHB) is a biodegradable and thermoprocessable biopolymer, making it a promising candidate for applications in tissue engineering. In the present study a structural characterization and in vitro evaluation were performed on PHB scaffolds produced by additive manufacturing via selective laser sintering (SLS), followed by post-printing functionalization with osteogenic growth peptide (OGP) and its C-terminal sequence OGP(10-14). The PHB scaffolds were characterized, including their morphology, porosity, thermal and mechanical properties, moreover OGP release. The results showed that SLS technology allowed the sintering of the PHB scaffolds with a hierarchical structure with interconnected pores and intrinsic porosity (porosity of 55.8 ± 0.7% and pore size in the 500-700 μm range), and good mechanical properties. Furthermore, the SLS technology did not change thermal properties of PHB polymer. The OGP release profile showed that PHB scaffold promoted a controlled release above 72 h. In vitro assays using rat bone marrow stem cells showed good cell viability/proliferation in all the PHB scaffolds. Additionally, SEM images suggested advanced morphological differentiation in the groups containing osteogenic growth peptide. The overall results demonstrated that PHB biopolymer is potential candidate for 3D printing via SLS technology, moreover the OGP-containing PHB scaffolds showed ability to sustain cell growth to support tissue formation thereby might be considered for tissue-engineering applications.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.msec.2018.04.016

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 94

Metadata

Authors
Saska, S., Pires, L. C., Cominotte, M. A., Mendes, L. S., de Oliveira, M. F., Maia, I. A., da Silva, J. V. L., Ribeiro, S. J. L., & Cirelli, J. A.
Venue
Materials Science and Engineering: C
Publisher
Elsevier BV
Published
2018-08
Volume
89
Pages
265-273
ISSN
0928-4931 (ISSN-L)
OpenAlex
W2797209190
Cited by
94
References
3
FWCI
4.25
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Three-dimensional printing and in vitro evaluation of poly(3-hydroxybutyrate) scaffolds functionalized with osteogenic growth peptide for tissue engineering. https://app.cochat.ai/papers/10.1016/j.msec.2018.04.016
The paper
Saska, S., Pires, L. C., Cominotte, M. A., Mendes, L. S., de Oliveira, M. F., Maia, I. A., da Silva, J. V. L., Ribeiro, S. J. L., & Cirelli, J. A. (2018). Three-dimensional printing and in vitro evaluation of poly(3-hydroxybutyrate) scaffolds functionalized with osteogenic growth peptide for tissue engineering. Materials Science and Engineering: C. https://doi.org/10.1016/j.msec.2018.04.016

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.