CoChat

Hydrogel-forming microneedles for rapid and efficient skin deposition of controlled release tip-implants

Open access
Peng, Ke, Vora, Lalitkumar K., Domínguez-Robles, Juan, Naser, Yara A., Li, Mingshan, Larrañeta, Eneko, Donnelly, Ryan F. · 2021 · Materials Science and Engineering: C
Cited by 110

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

In this work, we introduce, for the first time, novel hybrid microneedle patches with implantable poly(lactic-co-glycolic acid) (PLGA) tips aligned with hydrogel-forming microneedle bases (HFMB) using a dissolvable material. A model dye, Nile red, and an antifungal drug, amphotericin B, were loaded into the PLGA tips in a controlled manner by multiple castings. Three different types of pre-formed microneedle bases including conventional dissolving baseplates (MN0), HFMB with needle heights of 600 μm (MN6) and HFMB with needle heights of 800 μm (MN8) were investigated. Compared to the conventional dissolving baseplate (MN0)-based PLGA tipped implantable microneedle design, the addition of the pre-formed HFMB (MN8) improved in vitro and ex vivo insertion capacities of the patches, increased ex vivo drug delivery efficiency up to 80% of the loaded drug and speeded up the implantation process to within 1 min. An adhesion test indicated that the hydrogel baseplate used in this study was easier to peel off from the skin than the dissolving baseplate. In vitro release studies demonstrated that the release of amphotericin B from the drug loading PLGA tips lasts for a week. Antifungal tests of the inserted amphotericin B loaded PLGA tips revealed their antifungal effects against Candida albicans. The MN8 did not dissolve, leaving no viscous residue but absorbed water and disintegrated after immersion into water. The hybrid PLGA-tipped microneedle system will be ideal for rapid implantation and sustained release of amphotericin B for dermal fungal infections. This hybrid patch design is a novel promising technology for delivering drug-eluting microimplants into the skin while ensuring easy and complete removal of the HFMB. It could have many potential applications in implantable intradermal drug delivery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.msec.2021.112226

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 110

Metadata

Authors
Peng, K., Vora, L. K., Domínguez-Robles, J., Naser, Y. A., Li, M., Larrañeta, E., & Donnelly, R. F.
Venue
Materials Science and Engineering: C
Publisher
Elsevier BV
Published
2021-08
Volume
127
Pages
112226
ISSN
0928-4931 (ISSN-L)
OpenAlex
W3170463987
Cited by
110
References
4
FWCI
6.06
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.