The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
High-performance flexible lead-free nanocomposite piezoelectric nanogenerator for biomechanical energy harvesting and storage
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nanotechnology‐Enabled Energy Harvesting for Self‐Powered Micro‐/Nanosystems
Wang, Z. L., & Wu, W. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201201656 · Cited by 1,063
Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., et al. (2014) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1317233111 · Cited by 975
Flexible High-Output Nanogenerator Based on Lateral ZnO Nanowire Array
Zhu, G., Yang, R., Wang, S., & Wang, Z. L. (2010) · Nano Letters · doi:10.1021/nl101973h · Cited by 805
Yang, Y., Zhang, H., Lin, Z.-H., Zhou, Y. S., Jing, Q., Su, Y., Yang, J., Chen, J., Hu, C., & Wang, Z. L. (2013) · ACS Nano · doi:10.1021/nn403838y · Cited by 798
Hwang, G., Park, H., Lee, J., Oh, S., Park, K., Byun, M., Park, H., Ahn, G., Jeong, C. K., No, K., et al. (2014) · Advanced Materials · doi:10.1002/adma.201400562 · Cited by 672
A Flexible Bimodal Sensor Array for Simultaneous Sensing of Pressure and Temperature
Tien, N. T., Jeon, S., Kim, D., Trung, T. Q., Jang, M., Hwang, B., Byun, K., Bae, J., Lee, E., Tok, J. B. ‐., et al. (2014) · Advanced Materials · doi:10.1002/adma.201302869 · Cited by 438
Self-citation
Cited by
Monitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Surmenev, R. A., Orlova, T., Chernozem, R. V., Ivanova, A. A., Bartasyte, A., Mathur, S., & Surmeneva, M. A. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.04.090 · Cited by 357
PVDF‐based dielectric polymers and their applications in electronic materials
Xia, W., & Zhang, Z. (2018) · IET Nanodielectrics · doi:10.1049/iet-nde.2018.0001 · Cited by 346
Stadlober, B., Zirkl, M., & Irimia-Vladu, M. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00928g · Cited by 339
Metadata
- Authors
- Siddiqui, S., Kim, D.-I., Duy, L. T., Nguyen, M. T., Muhammad, S., Yoon, W.-S., & Lee, N.-E.
- Venue
- Nano Energy
- Publisher
- Elsevier BV
- Published
- 2015-07
- Volume
- 15
- Pages
- 177-185
- ISSN
- 2211-2855 (ISSN-L)
- OpenAlex
- W284223449
- Cited by
- 263
- References
- 6
- FWCI
- 9.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-performance flexible lead-free nanocomposite piezoelectric nanogenerator for biomechanical energy harvesting and storage. https://app.cochat.ai/papers/10.1016/j.nanoen.2015.04.030
- The paper
- Siddiqui, S., Kim, D.-I., Duy, L. T., Nguyen, M. T., Muhammad, S., Yoon, W.-S., & Lee, N.-E. (2015). High-performance flexible lead-free nanocomposite piezoelectric nanogenerator for biomechanical energy harvesting and storage. Nano Energy. https://doi.org/10.1016/j.nanoen.2015.04.030
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.