Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 216

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Capillary-driven liquid film boiling heat transfer on hybrid mesh wicking structures

Open access
Wen, Rongfu, Xu, Shanshan, Lee, Yung-Cheng, Yang, Ronggui · 2018 · Nano Energy

Abstract

Abstract Thermal management of high power electronic systems such as advanced lasers, light emitting diodes, radars, microprocessors, electrical machines, and power inverters, is becoming critical in defense, space, and commercial applications. As a liquid-vapor phase-change process, capillary evaporation on wicking structures has received increased interest owing to its capability dissipating high heat flux by increasing the effective evaporation area and sustaining the liquid supply. However, the approaches based on capillary evaporation suffer from intrinsic tradeoffs between the low thermal resistance for heat flow and the high wicking flow rate for liquid supply, which make it challenging to optimize both heat transfer coefficient (HTC) and critical heat flux (CHF) on the same wicking structure. Here, we present a cost-effective hybrid wicking structure, that can be scalably manufactured using commercial copper micromeshes along with simple etching processes, to enable a novel capillary-driven liquid film boiling heat transfer by simultaneously improving liquid supply and increasing nucleation sites. The interconnected microchannels between woven mesh layers and the substrate serve as low flow resistance passages for high volumetric flow rate of the liquid. Through creating nanograsses and microcavities on the multilayer micromeshes, the liquid flow is enhanced for higher CHF due to the increased surface wettability. Moreover, a plural of microcavities on the mesh surface decrease the superheat for early onset of nucleate boiling (ONB), resulting in higher HTC. Enhanced CHF (198.6 W/cm2) and HTC (138.7 kW/m2 K) are observed on the hybrid mesh wicking structure with a 10 mm × 10 mm heated area due to more than twice the flow rate for liquid supply and more than one third reduced superheat at the ONB, compared to that on the plain mesh wicking structure. The insights gained from this study can be used to guide the design and manufacturing of highly efficient wicking structures in heat pipes, vapor chambers, and other high flux thermal systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.nanoen.2018.06.063

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 216

Metadata

Authors
Wen, R., Xu, S., Lee, Y.-C., & Yang, R.
Venue
Nano Energy
Publisher
Elsevier BV
Published
2018-09
Volume
51
Pages
373-382
ISSN
2211-2855 (ISSN-L)
OpenAlex
W2809072980
Cited by
216
References
3
FWCI
8.31
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Capillary-driven liquid film boiling heat transfer on hybrid mesh wicking structures. https://app.cochat.ai/papers/10.1016/j.nanoen.2018.06.063
The paper
Wen, R., Xu, S., Lee, Y.-C., & Yang, R. (2018). Capillary-driven liquid film boiling heat transfer on hybrid mesh wicking structures. Nano Energy. https://doi.org/10.1016/j.nanoen.2018.06.063

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.