Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 548

The DOI matches its Crossref record; 43 of the 43 references it cites were found in a registry or an index.

A flexible, ultra-highly sensitive and stable capacitive pressure sensor with convex microarrays for motion and health monitoring

Open access
Xiong, Yaoxu, Shen, Youkang, Tian, Lan, Hu, Yougen, Zhu, Pengli, Sun, Rong, Wong, Ching-Ping·2020·Nano Energy

Abstract

Abstract Recently, flexible sensors endowed with high sensitivity, low detection limit, broad working pressure range and fast response have aroused widespread concern owing to their vital role in the development of wearable artificial devices, human-machine interaction and healthcare systems. Herein, flexible and highly sensitive capacitive pressure sensors were fabricated based on flexible electrodes with convex microarrays and ultrathin dielectric layer. The proposed sensor is constructed by sandwiching a top micro-arrayed electrode, a middle ultrathin dielectric layer and a bottom micro-arrayed electrode, and it demonstrates an ultra-high sensitivity of 30.2 kPa−1 (0–130 Pa), fast response time of 25 ms, low detection limit of 0.7 Pa and extreme stability of 100 000 cycles without fatigue. The finite-element analysis indicates that the changes of contact area and distance between two electrodes under external stimulus are critical to achieve superior properties of the sensor. Benefitting from the outstanding comprehensive performance, the enormous potential ability of the capacitive sensor in monitoring physiological signals and robot hand grabbing motions have been successfully demonstrated, which indicates promising applications in wearable intelligent electronic devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.nanoen.2019.104436

Cites

43 of 43 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 43 references

Cited by

See all 548

Metadata

Authors
Xiong, Y., Shen, Y., Tian, L., Hu, Y., Zhu, P., Sun, R., & Wong, C.-P.
Venue
Nano Energy
Publisher
Elsevier BV
Published
2020-04
Volume
70
Pages
104436
ISSN
2211-2855 (ISSN-L)
OpenAlex
W3000169617
Cited by
548
References
43
FWCI
24.03
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A flexible, ultra-highly sensitive and stable capacitive pressure sensor with convex microarrays for motion and health monitoring. https://app.cochat.ai/papers/10.1016/j.nanoen.2019.104436
The paper
Xiong, Y., Shen, Y., Tian, L., Hu, Y., Zhu, P., Sun, R., & Wong, C.-P. (2020). A flexible, ultra-highly sensitive and stable capacitive pressure sensor with convex microarrays for motion and health monitoring. Nano Energy. https://doi.org/10.1016/j.nanoen.2019.104436

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.