Cited by 114Advanced Sensor and Energy Harvesting MaterialsTribology and Wear AnalysisElectrochemical sensors and biosensors

Investigated a PLL surface-modified Nylon 11 electrospun as a highly tribo-positive frictional layer to enhance output performance of triboelectric nanogenerators and self-powered wearable sensors

Prasad, Gajula, Graham, Sontyana Adonijah, Yu, Jae Su, Kim, Hongdoo, Lee, Dong-Weon·2023·Nano Energy

Integrity signals

Registry

Crossref · 10.1016/j.nanoen.2023.108178

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Prasad et al. reported that SrTiO3-integrated Ecoflex composites retain flexibility while enhancing performance, achieving 270 V and 7.2 μA under 12.5 N with high sensitivity (9 V/Pa), ideal for healthcare, motion detection, and smart wearables.

    “For example, Prasad et al. [55] reported that SrTiO 3 -integrated Ecoflex composites retain flexibility while enhancing performance, achieving 270 V and 7.2 µA under 12.5 N with high sensitivity (9 V/Pa), which was ideal for healthcare, motion detection, and smart wearables.”
  • These features made the sensor well-suited for wearable applications, including pulse monitoring and acoustic detection.

    “These features made it well-suited for wearable applications, including pulse monitoring and acoustic detection (Figure 14) [55,59,63,[212][213][214][215].”
  • The incorporation of MXene and SrTiO3 to Ecoflex improved tribo-negativity, with the 10 wt% SrTiO3-embedded Ecoflex composite achieving a VOC of 270 V and ISC of 7.2 μA under pressure.

    “The incorporation of MXene and SrTiO 3 to Ecoflex improved tribo-negativity, with the 10 wt% SrTiO 3 -embedded Ecoflex composite achieving a V OC of 270 V and I SC of 7.2 µA under pressure.”
  • This device powered electronics and detected human motions, showing potential for self-powered wearable sensors.

    “This device powered electronics and detected human motions, showing potential for self-powered wearable sensors (Figure 14G).”
  • Prasad et al. enhanced Nylon 11 films with PLL modification, boosting TENG performance by over five times in open circuit potential (VOC) and four times in short circuit current (ISC).

    “Moreover, Prasad et al. [55] enhanced Nylon 11 films with PLL modification, boosting TENG performance by over five times in open circuit potential (V OC ) and four times in short circuit current (I SC ).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Prasad, G., Graham, S. A., Yu, J. S., Kim, H., & Lee, D.-W.
Affiliations
  • Kyung Hee University (KR)
  • Chonnam National University (KR)
Corresponding author
Lee, Dong-Weon
Venue
Nano Energy
Publisher
Elsevier BV
Published
2023-04
Volume
108
Pages
108178
ISSN
2211-2855 (ISSN-L)
OpenAlex
W4313888063
Cited by
114
References
3
Citations by year
2026: 17 · 2025: 33 · 2024: 44 · 2023: 20
FWCI
9.02
Type
journal article
Language
en
Open access
closed
Locations
Nano Energy (publishedVersion)
Funders
National Research Foundation of Korea
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Mechanics of Materials › Tribology and Wear Analysis
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrochemical sensors and biosensors
Keywords
triboelectric nanogenerator, MXene, self-powered wearable sensors, flexible energy harvesting

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review