Microfluidic hydrodynamic focusing for synthesis of nanomaterials
Open accessThe DOI matches its Crossref record; 102 of the 102 references it cites were found in a registry or an index.
Abstract
Microfluidics expands the synthetic space such as heat transfer, mass transport, and reagent consumption to conditions not easily achievable in conventional batch processes. Hydrodynamic focusing in particular enables the generation and study of complex engineered nanostructures and new materials systems. In this review, we present an overview of recent progress in the synthesis of nanostructures and microfibers using microfluidic hydrodynamic focusing techniques. Emphasis is placed on distinct designs of flow focusing methods and their associated mechanisms, as well as their applications in material synthesis, determination of reaction kinetics, and study of synthetic mechanisms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Synthesis and surface engineering of iron oxide nanoparticles for biomedical applications
Gupta, A. K., & Gupta, M. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.10.012 · Cited by 6,771
Determining the Size and Shape Dependence of Gold Nanoparticle Uptake into Mammalian Cells
Chithrani, B. D., Ghazani, A. A., & Chan, W. C. W. (2006) · Nano Letters · doi:10.1021/nl052396o · Cited by 4,879 · cited 1×
“For example, the extinction spectra of gold and silver nanoparticles, and the uptake of gold nanoparticles by mammalian cells, depend on their size and shape [108].”
BackgroundGreen synthesis of metal nanoparticles using plants
Iravani, S. (2011) · Green Chemistry · doi:10.1039/c1gc15386b · Cited by 3,823
Reynolds, O. (1883) · Philosophical Transactions of the Royal Society of London · doi:10.1098/rstl.1883.0029 · Cited by 2,262
New developments in liposomal drug delivery
Pattni, B. S., Chupin, V. V., & Torchilin, V. P. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00046 · Cited by 1,600 · cited 1×
“Liposomes are highly functional products of microfluidic HF method due to their ability to encapsulate aqueous components for delivery of genes, drugs and other therapeutic agents, and be used as contrast agents [82].”
BackgroundThe past, present and potential for microfluidic reactor technology in chemical synthesis
Elvira, K. S., i Solvas, X. C., Wootton, R. C. R., & deMello, A. J. (2013) · Nature Chemistry · doi:10.1038/nchem.1753 · Cited by 1,203 · cited 1×
“In the past several decades, a diverse range of microfluidic reactors have been designed for synthesis of a variety of functional materials [8].”
BackgroundLee, C.-Y., Chang, C.-L., Wang, Y.-N., & Fu, L.-M. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12053263 · Cited by 1,111 · cited 1×
“In low Re microfluidic systems, various mixing mechanisms have been demonstrated [17] using active approaches, such as magnetic [18,19], electrokinetic [20], acoustic [21–23], optical based [24] as well as passive approaches such as tesla microstructures [25,26], serpentine channels [27], and lamination [28].”
MethodFundamentals and applications of inertial microfluidics: a review
Zhang, J., Yan, S., Yuan, D., Alici, G., Nguyen, N.-T., Ebrahimi Warkiani, M., & Li, W. (2016) · Lab on a Chip · doi:10.1039/c5lc01159k · Cited by 1,017 · cited 1×
“On these microscopic scales, the fluid behavior is primarily influenced by viscosity rather than inertia, and the ratio of surface area to volume becomes larger providing rapid heat and mass transfer [6].”
BackgroundMicrofluidic Platform for Controlled Synthesis of Polymeric Nanoparticles
Karnik, R., Gu, F., Basto, P., Cannizzaro, C., Dean, L., Kyei-Manu, W., Langer, R., & Farokhzad, O. C. (2008) · Nano Letters · doi:10.1021/nl801736q · Cited by 887 · cited 3×
“By controlling the relative flow rates of the chemical components, the concentration and solubility can be controlled, which in turn determines the size of the growing nuclei [36,37].”
BackgroundMethodHydrodynamic Focusing on a Silicon Chip: Mixing Nanoliters in Microseconds
Knight, J. B., Vishwanath, A., Brody, J. P., & Austin, R. H. (1998) · Physical Review Letters · doi:10.1103/physrevlett.80.3863 · Cited by 887 · cited 1×
“Using this geometry, the mixing time can be reduced to less than 50 microseconds [50].”
Method
Cited by
Microfluidic Nanoparticles for Drug Delivery
Liu, Y., Yang, G., Hui, Y., Ranaweera, S., & Zhao, C. (2022) · Small · doi:10.1002/smll.202106580 · Cited by 277
Microfluidic-assisted fabrication of carriers for controlled drug delivery
Liu, D., Zhang, H., Fontana, F., Hirvonen, J. T., & Santos, H. A. (2017) · Lab on a Chip · doi:10.1039/c7lc00242d · Cited by 254
Synthesis, Functionalization, and Design of Magnetic Nanoparticles for Theranostic Applications
Mosayebi, J., Kiyasatfar, M., & Laurent, S. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700306 · Cited by 241
Liu, D., Zhang, H., Fontana, F., Hirvonen, J. T., & Santos, H. A. (2018) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2017.08.003 · Cited by 238
“The mixing time directly affects the average particle size and size distribution of the obtained nanoparticles [17, 18, 29].”
BackgroundInfluentialMicrofluidic assisted synthesis of PLGA drug delivery systems
Rezvantalab, S., & Keshavarz Moraveji, M. (2019) · RSC Advances · doi:10.1039/c8ra08972h · Cited by 160
Metadata
- Authors
- Lu, M., Ozcelik, A., Grigsby, C. L., Zhao, Y., Guo, F., Leong, K. W., & Huang, T. J.
- Venue
- Nano Today
- Publisher
- Elsevier BV
- Published
- 2016-12
- Volume
- 11
- Issue
- 6
- Pages
- 778-792
- ISSN
- 1748-0132 (ISSN-L)
- OpenAlex
- W2551207187
- Cited by
- 200
- References
- 102
- FWCI
- 6.99
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.