Functional near-infrared spectroscopy (fNIRS) is an optical imaging method that can be used for a brain-computer interface (BCI). In the present study, we concurrently measure and discriminate fNIRS signals evoked by three different mental activities, that is, mental arithmetic (MA), right-hand motor imagery (RI), and left-hand motor imagery (LI). Ten healthy subjects were asked to perform the MA, RI, and LI during a 10s task period. Using a continuous-wave NIRS system, signals were acquired concurrently from the prefrontal and the primary motor cortices. Multiclass linear discriminant analysis was utilized to classify MA vs. RI vs. LI with an average classification accuracy of 75.6% across the ten subjects, for a 2-7s time window during the a 10s task period. These results demonstrate the feasibility of implementing a three-class fNIRS-BCI using three different intentionally-generated cognitive tasks as inputs.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The current BCI systems do not have the ability to decode movement intention, instead they use imagination based tasks for control (Hong and Nguyen, 2014; Khan et al., 2014; Hong et al., 2015).”
From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Hong et al., 2015
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665
Zander, T. O., & Kothe, C. A. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025005 · Cited by 947
Porro, C. A., Francescato, M. P., Cettolo, V., Diamond, M. E., Baraldi, P., Zuiani, C., Bazzocchi, M., & di Prampero, P. E. (1996) · The Journal of Neuroscience · doi:10.1523/jneurosci.16-23-07688.1996 · Cited by 924
Sitaram, R., Zhang, H., Guan, C., Thulasidas, M., Hoshi, Y., Ishikawa, A., Shimizu, K., & Birbaumer, N. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.11.005 · Cited by 598
Brain–computer interface using a simplified functional near-infrared spectroscopy system
Coyle, S. M., Ward, T. E., & Markham, C. M. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/3/007 · Cited by 505
On the suitability of near-infrared (NIR) systems for next-generation brain–computer interfaces
Coyle, S. M., Ward, T. E., Markham, C., & McDarby, G. (2004) · Physiological Measurement · doi:10.1088/0967-3334/25/4/003 · Cited by 361
Naseer, N., & Hong, K. (2013) · Neuroscience Letters · doi:10.1016/j.neulet.2013.08.021 · Cited by 301
Decoding of four movement directions using hybrid NIRS-EEG brain-computer interface
Khan, M. J., Hong, M. J., & Hong, K.-S. (2014) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2014.00244 · Cited by 280
Noninvasive Functional Imaging of Human Brain Using Light
Benaron, D. A., Hintz, S. R., Villringer, A., Boas, D. A., Kleinschmidt, A. K., Frahm, J., Hirth, C., Obrig, H., van Houten, J. P., Kermit, E. L., et al. (2000) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200003000-00005 · Cited by 238
Naseer, N., Hong, M. J., & Hong, K. (2013) · Experimental Brain Research · doi:10.1007/s00221-013-3764-1 · Cited by 228
NAITO, M., Michioka, Y., OZAWA, K., ITO, Y., Kiguchi, M., & KANAZAWA, T. (2007) · IEICE Transactions on Information and Systems · doi:10.1093/ietisy/e90-d.7.1028 · Cited by 223
Gagnon, L., Yücel, M. A., Dehaes, M., Cooper, R. J., Perdue, K. L., Selb, J. J., Huppert, T. J., Hoge, R. D., & Boas, D. A. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.10.054 · Cited by 213
Intracerebral penetration of infrared light
McCormick, P. W., Stewart, M., Lewis, G. D., Dujovny, M., & Ausman, J. I. (1992) · Journal of neurosurgery · doi:10.3171/jns.1992.76.2.0315 · Cited by 204
Mental representations of movements. Brain potentials associated with imagination of eye movements
Höllinger, P., Beisteiner, R., Lang, W., Lindinger, G., & Berthoz, A. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(98)00042-x · Cited by 194
Mental representations of movements. Brain potentials associated with imagination of hand movements
Beisteiner, R., Höllinger, P., Lindinger, G., Lang, W., & Berthoz, A. (1995) · Electroencephalography and Clinical Neurophysiology/Evoked Potentials Section · doi:10.1016/0168-5597(94)00226-5 · Cited by 173
Noise reduction in functional near-infrared spectroscopy signals by independent component analysis
Santosa, H., Hong, M. J., Kim, S.-P., & Hong, K. (2013) · Review of Scientific Instruments · doi:10.1063/1.4812785 · Cited by 172
Power, S., Falk, T. H., & Chau, T. T. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/2/026002 · Cited by 160
Power, S., Kushki, A., & Chau, T. T. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/6/066004 · Cited by 151
Hu, X., Hong, K., Ge, S. S., & Jeong, M.-Y. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-82 · Cited by 143
Effects of measurement method, wavelength, and source-detector distance on the fast optical signal
Gratton, G., Brumback, C. R., Gordon, B. A., Pearson, M. A., Low, K. A., & Fabiani, M. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.05.030 · Cited by 135
fNIRS-based online deception decoding
Hu, X., Hong, K., & Ge, S. S. (2012) · Journal of Neural Engineering · doi:10.1088/1741-2560/9/2/026012 · Cited by 130
Honoring Leslie A. Geddes - Farewell ...
Valentinuzzi, M. E. (2010) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-9-1 · Cited by 130
Power, S., Kushki, A., & Chau, T. T. (2012) · BMC Research Notes · doi:10.1186/1756-0500-5-141 · Cited by 105
State-space models of impulse hemodynamic responses over motor, somatosensory, and visual cortices
Hong, K.-S., & Nguyen, H.-D. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.001778 · Cited by 92
Self-citationHu, X., Hong, K., & Ge, S. S. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.1.017003 · Cited by 87
Brain activity during the flow experience: A functional near-infrared spectroscopy study
Yoshida, K., Sawamura, D., Inagaki, Y., Ogawa, K., Ikoma, K., & Sakai, S. (2014) · Neuroscience Letters · doi:10.1016/j.neulet.2014.05.011 · Cited by 86
Power, S., Kushki, A., & Chau, T. T. (2012) · PLoS ONE · doi:10.1371/journal.pone.0037791 · Cited by 83
Frederick, B. B., Nickerson, L. D. H., & Tong, Y. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.01.140 · Cited by 80
Hu, X., Hong, K., & Ge, S. S. (2011) · Neuroscience Letters · doi:10.1016/j.neulet.2011.09.011 · Cited by 80
Bhutta, M. R., Hong, K., Kim, B.-M., Hong, M. J., Kim, Y.-H., & Lee, S. (2014) · Review of Scientific Instruments · doi:10.1063/1.4865124 · Cited by 76
Kamran, M. A., & Hong, K. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056002 · Cited by 67
Aqil, M., Hong, K., Jeong, M.-Y., & Ge, S. S. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.07.006 · Cited by 64
Cortical brain imaging by adaptive filtering of NIRS signals
Aqil, M., Hong, K., Jeong, M.-Y., & Ge, S. S. (2012) · Neuroscience Letters · doi:10.1016/j.neulet.2012.02.048 · Cited by 64
Reduction of physiological effects in fNIRS waveforms for efficient brain-state decoding
Kamran, M. A., & Hong, K. (2014) · Neuroscience Letters · doi:10.1016/j.neulet.2014.07.058 · Cited by 51
Characterizing emotional response to music in the prefrontal cortex using near infrared spectroscopy
Moghimi, S., Kushki, A., Guerguerian, A. M., & Chau, T. T. (2012) · Neuroscience Letters · doi:10.1016/j.neulet.2012.07.009 · Cited by 39
Köchel, A., Schöngaßner, F., & Schienle, A. (2013) · Neuroscience Letters · doi:10.1016/j.neulet.2013.06.062 · Cited by 36
Salvaris, M., & Sepulveda, F. (2010) · Journal of Neural Engineering · doi:10.1088/1741-2560/7/5/056004 · Cited by 36
Yue, J., Zhou, Z., Jiang, J., Liu, Y., & Hu, D. (2012) · Neuroscience Letters · doi:10.1016/j.neulet.2012.07.031 · Cited by 27
A noninvasive brain computer interface using visually-induced near-infrared spectroscopy responses
Chen, C.-H., Ho, M.-S., Shyu, K., Hsu, K.-C., Wang, K.-W., & Lee, P. (2014) · Neuroscience Letters · doi:10.1016/j.neulet.2014.07.042 · Cited by 15
Improving Classification by Feature Discretization and Optimization for fNIRS-based BCI
Xu, B., Fu, Y., Shi, G., Yin, X., Wang, Z., & Li, H. (2014) · doi:10.4172/1662-100x.1000119 · Cited by 9
Cited by
Sorted by citations
fNIRS-based brain-computer interfaces: a review
Naseer, N., & Hong, K.-S. (2015) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2015.00003 · Cited by 988
Sleep Stage Classification Using EEG Signal Analysis: A Comprehensive Survey and New Investigation
Aboalayon, K. A. I., Faezipour, M., Almuhammadi, W. S., & Moslehpour, S. (2016) · Entropy · doi:10.3390/e18090272 · Cited by 387
Open Access Dataset for EEG+NIRS Single-Trial Classification
Shin, J., von Lühmann, A., Blankertz, B., Kim, D.-W., Jeong, J., Hwang, H., & Müller, K. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2628057 · Cited by 283
Mental stress assessment using simultaneous measurement of EEG and fNIRS
Al-Shargie, F., Kiguchi, M., Badruddin, N., Dass, S. C., Hani, A. F. M., & Tang, T. B. (2016) · Biomedical Optics Express · doi:10.1364/boe.7.003882 · Cited by 293
Feature Extraction and Classification Methods for Hybrid fNIRS-EEG Brain-Computer Interfaces
Hong, K., Khan, M. J., & Hong, M. J. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2018.00246 · Cited by 287
Metadata
- Authors
- Hong, K.-S., Naseer, N., & Kim, Y.-H.
- Affiliations
- Pusan National University (KR)
- Samsung Medical Center (KR)
- Corresponding author
- Hong, Keum-Shik
- Venue
- Neuroscience Letters
- Publisher
- Elsevier BV
- Published
- 2015-02
- Volume
- 587
- Pages
- 87-92
- ISSN
- 0304-3940 (ISSN-L)
- OpenAlex
- W2066303625
- Cited by
- 276
- References
- 42
- Citations by year
- 2026: 4 · 2025: 8 · 2024: 10 · 2023: 14 · 2022: 17 · 2021: 32 · 2020: 36 · 2019: 30 · 2018: 43 · 2017: 28 · 2016: 28 · 2015: 26
- FWCI
- 15.24
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Neuroscience Letters (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Research Foundation of Korea under the Ministry of Science, ICT and Future Planning (NRF-2014R1A2A1A10049727, NRF-2014R1A2A1A01005128)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
- Keywords
- functional near-infrared spectroscopy, brain-computer interface, prefrontal cortex, primary motor cortex, motor imagery, mental arithmetic, three-class classification, linear discriminant analysis, continuous-wave NIRS
- MeSH terms
- Adult, Feasibility Studies, Humans, Imagination, Functional Laterality, Male, Motor Activity, Motor Cortex, Problem Solving, Discriminant Analysis, Linear Models, Prefrontal Cortex, Spectroscopy, Near-Infrared, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review