Cited by 92Optical Imaging and Spectroscopy TechniquesAdvanced MRI Techniques and ApplicationsNon-Invasive Vital Sign Monitoring

State-space models of impulse hemodynamic responses over motor, somatosensory, and visual cortices

Open access
Hong, Keum-Shik, Nguyen, Hoang-Dung·2014·Biomedical Optics Express

Abstract

THE PAPER PRESENTS STATE SPACE MODELS OF THE HEMODYNAMIC RESPONSE (HR) OF FNIRS TO AN IMPULSE STIMULUS IN THREE BRAIN REGIONS: motor cortex (MC), somatosensory cortex (SC), and visual cortex (VC). Nineteen healthy subjects were examined. For each cortex, three impulse HRs experimentally obtained were averaged. The averaged signal was converted to a state space equation by using the subspace method. The activation peak and the undershoot peak of the oxy-hemoglobin (HbO) in MC are noticeably higher than those in SC and VC. The time-to-peaks of the HbO in three brain regions are almost the same (about 6.76 76 ± 0.2 s). The time to undershoot peak in VC is the largest among three. The HbO decreases in the early stage (~0.46 s) in MC and VC, but it is not so in SC. These findings were well described with the developed state space equations. Another advantage of the proposed method is its easy applicability in generating the expected HR to arbitrary stimuli in an online (or real-time) imaging. Experimental results are demonstrated.

Integrity signals

Registry

Crossref · 10.1364/boe.5.001778

Cites

37 of 37 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Current BCI systems do not have ability to decode movement intention, instead use imagination based tasks for control.

    “The current BCI systems do not have the ability to decode movement intention, instead they use imagination based tasks for control (Hong and Nguyen, 2014; Khan et al., 2014; Hong et al., 2015).”

    From Selectivity and Longevity of Peripheral-Nerve and Machine Interfaces: A Review. (2017) · cites this paper as Hong and Nguyen, 2014

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Hong, K.-S., & Nguyen, H.-D.
Affiliations
Pusan National University (KR)
Venue
Biomedical Optics Express
Published
2014-05-09
Volume
5
Issue
6
Pages
1778
ISSN
2156-7085 (ISSN-L)
OpenAlex
W2108596771
Cited by
92
References
37
Citations by year
2025: 1 · 2023: 2 · 2022: 5 · 2021: 6 · 2020: 4 · 2019: 9 · 2018: 17 · 2017: 13 · 2016: 16 · 2015: 15 · 2014: 4
FWCI
12.52
Type
journal article
Language
en
Open access
Locations
  • Biomedical Optics Express (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
functional near-infrared spectroscopy, hemodynamic response, state-space model, subspace methods, motor cortex, somatosensory cortex, visual cortex, oxyhemoglobin

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review